1.1 ELECTRICAL SAFETY
WARNING! It is the responsibility of the owner and the operator to read, understand and comply with the following:
You must check all electrical products, before use, to ensure that they are safe. You must inspect power cables, plugs, sockets and
any other connectors for wear or damage. You must ensure that the risk of electric shock is minimised by the installation of
appropriate safety devices. A Residual Current Circuit Breaker (RCCB) should be incorporated in the main distribution board. We also
recommend that a Residual Current Device (RCD) is used. It is particularly important to use an RCD with portable products that are
plugged into a supply which is not protected by an RCCB. If in any doubt consult a qualified electrician. You may obtain a Residual
Current Device by contacting your Sealey dealer.
You must also read and understand the following instructions concerning electrical safety.
1.1.1 The Electricity at Work Act 1989 requires that all portable electrical appliances, if used on business premises, are tested by a qualified
electrician, using a Portable Appliance Tester (PAT), at least once a year.
1.1.2 The Health & Safety at Work Act 1974 makes owners of electrical appliances responsible for the safe condition of those appliances
and the safety of the appliance operators. If in any doubt about electrical safety, contact a qualified electrician.
1.1.3 Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply. See 1.1.1 and 1.1.2
and use a Portable Appliance Tester.
1.1.4 Ensure that cables are always protected against short circuit and overload.
1.1.5 Regularly inspect power supply cables and plugs for wear or damage and check all
connections to ensure that none are loose.
1.1.6 Important: Ensure that the voltage marked on the appliance matches the power supply to be
used and that the plug is fitted with the correct fuse - see fuse rating at right.
1.1.7 DO NOT pull or carry the appliance by the power cable.
1.1.8 DO NOT pull the plug from the socket by the cable.
1.1.9 DO NOT use worn or damaged cables, plugs or connectors. Immediately have any faulty item
repaired or replaced by a qualified electrician. When a BS 1363/A UK 3 pin plug is damaged,
cut the cable just above the plug and dispose of the plug safely.
Fit a new plug according to the following instructions (UK only).
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
d) After wiring, check that there are no bare wires, that all wires have been correctly connected, that the cable outer
insulation extends beyond the cable restraint and that the restraint is tight. Double insulated products, which are always
marked with this symbol , are fitted with live (brown) and neutral (blue) wires only. To rewire, connect the wires as
indicated above - DO NOT connect either wire to the earth terminal.
1.1.10 Products which require more than 13 amps are supplied without a plug. In this case you must contact a qualified electrician to ensure
that a suitably rated supply is available. We recommend that you discuss the installation of an industrial round pin plug and socket with
your electrician.
1.1.11 Use of an extension cord is not recommended. If an extension reel must be used it should be fully unwound before connection. A reel with
an RCD fitted is preferred since any appliance plugged into it will be protected. The cable core section is important and should be at least
2.5mm².
1.2 GENERAL SAFETY INSTRUCTIONS
Familiarise yourself with the applications and limitations of the heater.
Ensure that heater body is positioned on a rm, horizontal dry surface.
Keep away from ammable objects/materials/surfaces. This product gets very hot during use. Use in a location where accidental contact
(particularly by children) is unlikely.
Ensure on/off switches are set to ‘off’ before connecting power cord to power supply.
Ensure the heater is in good order and condition before use. If in any doubt do not use the unit and contact an electrician.
Only use recommended attachments and parts. To use unauthorised parts may be dangerous and will invalidate your warranty.
Check that element guard is in place, undamaged and firmly attached.
Keep tools and other items away from the heater when it is in use.
Keep the work area clean and clear of unnecessary items.
Keep children and unauthorised persons away from the heater, as it gets very hot.
Disconnect from mains and allow to cool before moving or attempting any cleaning or maintenance.
DO NOT get the heater wet or use in damp or wet locations or areas where there is condensation.
DO NOT locate the heater below the power outlet.
DO NOT remove plug from mains supply by pulling on power cord.
DO NOT move the heater whilst in operation or even when still warm.
DO NOT touch the heater elements, even when cold.
Always switch off heater, disconnect from power supply and allow cooling for at least one hour before attempting to touch heater cassette
or lamps.
DO NOT remove safety guard whilst heater is switched on. Turn off and allow cooling (as above) before servicing.
DO NOT disassemble the heater for any reason. The heater must be checked by qualified personnel only.
DO NOT use this product to perform a task for which it has not been designed.
DO NOT operate heater without safety guard or lamps installed.
DO NOT look directly at illuminated lamp(s).
WARNING! If a fuse blows, ensure it is replaced with an identical fuse type and rating.
FUSE RATING
13 AMP
Blue
Neutral
Wire
Yellow & Green
Earth Wire
Cable
Restraint
Brown
Live
Wire
1. SAFETY INSTRUCTIONS
INSTRUCTIONS FOR:
INFRARED CABINET HEATER
MODEL No: IRC1428
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly
maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS.
USE THIS PRODUCT CORRECTLY, AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE
AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
Original Language Version IRC1428 Issue: 1 - 21/05/10

3. LAMP INSTALLATION
NOTE! Hold the tube using the protective wrapping provided in its package or with a piece of clean dry cloth. If the tube glass surface
is touched, clean cold tube with alcohol and a soft cloth.
DO NOT touch a lamp just after switching ‘off’ its power supply. Temperature of a halogen lamp surface can exceed 600ºC during its operation.
3.1. Ensure that the lamps are;
a) The correct voltage rating for the power input, see rating plate on rear of unit.
b) Maximum of 1.4kW.
3.2. Remove safety guard on front of heater cassette by loosening and removing all 5 screws and lifting guard in an upward direction.
3.3. Remove tube from outer packaging carefully leaving it in its protective wrapping (Do Not touch halogen lamp quartz glass with bare
hands. Sweat and oils on fingers contain salt components that will cause a weak area and lead to premature lamp failure).
Expose the end caps of the tube and insert one end into one of the lamp holders. Push tube carefully against lamp holder until other end
of tube can be lowered into the other lamp holder.
3.4. Remove protective wrapping from lamp.
3.5. Repeat steps 3.3 for the other lamp.
3.6. Replace safety guard by locating the 3 slots on the bottom of the guard and secure all 5 screws. Do not over tighten.
2. INTRODUCTION & SPECIFICATION
Heavy-duty composite cabinet with two quartz infrared elements and
chemically polished reflectors for maximum heat emission.
Features protection grill and two heavy-duty plastic wheels for transport
over rough terrain. Controllable power output with rocker switches on the
rear of unit. Suitable for a wide variety of heating including restorative
applications. Supplied with cable and BS1363/A approved plug.
Max. Power: 2800W
Min. Power: 1400W
Input supply: 230V 13A
Dimensions (W x D x H): 500 x 460 x 1020mm
4. OPERATION
WARNING! Ensure you read, understand and apply the safety instructions in Section 1 before using the heater.
NOTE!The infrared lamp is fragile and therefore it is important that it is not subjected to any unnecessary shocks or vibration and is not moved
when it is on or until cooled down.
IMPORTANT: DURING RELOCATION, THE HEATER SHOULD REMAIN SWITCHED OFF AND DISCONNECTED FROM THE POWER
SU PPLY.
In the event of the heater being knocked over, a safety cut-out switch, which activates at an angle of 35º (±10º), will disable the heater.
Follow these steps to re-start the heater.
a) Switch ‘off’ the heater at the on/off switches. As Fig.2.
b) Disconnect the power cord from the power supply.
c) Return the heater to a standing position.
d) Check lamps are inserted correctly into lamp holders ensuring cooling time has been adhered (you may need to remove the safety
Guard, see 3. Lamp Installation).
e) If no damage has occurred to lamps or lamp holders, replace safety guard if applicable, re-connect power cord to the power supply and
switch the heater back on.
Should the power cord require replacement, a complete wiring loom should be purchased and fitted by a suitably qualified person.
4.1 Ensure the heater is at least 200cm from any object.
4.2 Plug in the heater and switch it on.
4.3 The heater has the following settings: See Fig.2.
Position 0:0 Off position.
Position I:0 Lower element only.
Position 0:I Upper element only.
Position I:I Both elements.
4.4 Make sure the heater plug is disconnected from the mains supply before any
cleaning is attempted. Also allow the heater to cool completely. Do not use water
or other liquids, or harsh abrasive cleaners to clean the heater.
4.5 Clean the exterior with a soft damp cloth with some mild detergent.
4.6 When the heater is no longer required, switch off and unplug the unit.
4.7 To replace any of the lamps, contact your authorised Sealey dealer.
DO NOT place any object on the safety guard of the heater cassette at any time.
WARNING! Never touch the element glass directly with fingers. Use a soft cloth, otherwise the tube may get damaged.
WARNING! Ensure the heater is at least 200cm from any object.
DO NOT leave unattended.
When not in use, store the heater carefully in a safe, dry, childproof location.
Fig.1
Fig.2 Fig.1
Heater Identification Fig.1
1) Heater Cassette 4) Heater Body
2) Safety Guard 5) Handle
3) Wheels for easy mobility 6) Switch Plate
Original Language Version IRC1428 Issue: 1 - 21/05/10

NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior notice.
IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our latest catalogue and promotions call us on 01284 757525 and leave your full name and address, including postcode.
01284 757500
01284 703534
sales@sealey.co.uk
Sole UK Distributor, Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,
IP32 7AR
www.sealey.co.uk
Web
email
Original Language Version IRC1428 Issue: 1 - 21/05/10
FAULT DESCRIPTION SUGGESTED SOLUTION
HEATER DOES NOT OPERATE • Check power supply.
• Check for damage or misalignment.
• Check all wiring connections.
OTHERS Consult a qualied electrician or contact a Sealey authorised dealer.
ELECTRICAL TEST, MAINTENANCE & STORAGE WARNING: THIS IS A CLASS 1 TESTED APPLIANCE
• When earth bond testing, the readings should be 0.10Ω and below.
• DO NOT perform a ash test, as this will reduce the life of the lamps.
• DO NOT use abrasive cleaners or polishes.
• Always switch ‘off’, disconnect the heater from the power supply and allow cooling for recommended time before cleaning. Clean the heater with a
damp cloth.
• When not in use, store the heater carefully in a safe, dry, childproof location.
5. TROUBLE SHOOTING
6. MAINTENANCE
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted,
taken to a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
Parts support is available for this product. To obtain a parts listing and/or diagram,
please log on to www.sealey.co.uk, email sales@sealey.co.uk or phone 01284 757500.
Table of contents
Other Sealey Heater manuals

Sealey
Sealey IR20.V4 User manual

Sealey
Sealey AB2050 User manual

Sealey
Sealey IRC153.V4 User manual

Sealey
Sealey EH2000 User manual

Sealey
Sealey CD2013 User manual

Sealey
Sealey IWMH2003 User manual

Sealey
Sealey SPACE WARMER LP41 User manual

Sealey
Sealey LP451R User manual

Sealey
Sealey VS240.V2 User manual

Sealey
Sealey LP1500 User manual

Sealey
Sealey IWMH2003 User manual

Sealey
Sealey AB80.V3 User manual

Sealey
Sealey PEH9001 User manual

Sealey
Sealey IWMH2003RC.V2 User manual

Sealey
Sealey RD800 User manual

Sealey
Sealey CH30 User manual

Sealey
Sealey AB502.V3 User manual

Sealey
Sealey SPACE WARMER AB2380 User manual

Sealey
Sealey EH3001 User manual

Sealey
Sealey IRH2200W User manual