manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sealey
  6. •
  7. Water Pump
  8. •
  9. Sealey WPD235A.V3 User manual

Sealey WPD235A.V3 User manual

AUTOMATIC SUBMERSIBLE DIRTY WATER
PUMPS 230V
MODEL NO’S: WPD235A.V3, WPS225A.V3
Thank you for purchasing a Sealey product. Manufactured to a high standard, this product will, if used according to these
instructions, and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE
THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGEAND/OR
PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. KEEP THESE INSTRUCTIONS SAFE FOR FUTURE USE.
1. SAFETY
1.1. ELECTRICAL SAFETY
WARNING! It is the user’s responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCD (Residual Current Device) is used with all electrical
products. You may obtain an RCD by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
Electrical safety information, it is important that the following information is read and understood.
1.1.1. Ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2. Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3. Important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is tted with the
correct fuse - see fuse rating in these instructions.
8DO NOT pull or carry the appliance by the power cable.
8DO NOT pull the plug from the socket by the cable.
8DO NOT use worn or damaged cables, plugs or connectors. Ensure that any faulty item is repaired
or replaced immediately by a qualied electrician.
1.1.4. This product is tted with a BS1363/A 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualied electrician.
Replace a damaged plug with a BS1363/A 3 pin plug. If in doubt contact a qualied electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal ‘E’.
b) Connect the BROWN live wire to the live terminal ‘L’.
c) Connect the BLUE neutral wire to the neutral terminal ‘N’.
Ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualied electrician.
1.1.5. Only allow the minimal amount of pump cable to enter water or wet areas. The electrical cable is
designed for use in water and must not be substituted. If damaged contact a qualied electrician.
1.1.6. Extension cable use. Only use a cable designed for use with water equipment. Contact your stockist or
a qualied electrician for advice. Ensure water is kept clear of electrical mains power supply. DO NOT touch switch or plug with wet
hands.
1.2. GENERAL SAFETY
  WARNING! Pump must be used in accordance with Health & Safety, government, local authority, and water authority rules and
regulations.
9The pump is to be supplied through a residual current device having a rated residual operating current, not exceeding 30mA.
9For cleaning and other maintenance to a swimming pool (if applicable):
9The pump must not be used when people are in the water;
9The pump must be supplied through a residual current device (RCD) having a rated residual operating current not exceeding 30mA
9The pump is to be supplied by an isolating transformer or supplied through a residual current device having a rated residual
operating current not exceeding 30mA.
9CAUTION – In order to avoid a hazard due to inadvertent resetting of the thermal cut-out, this appliance must not be supplied
through an external switching device, such a timer, or connected to a circuit that is regularly switched on and off by the utility.
9Familiarise yourself with application and limitations, as well as the specific potential hazards peculiar to the pump.
  WARNING! Disconnect the pump from the mains power before changing accessories, servicing or performing any maintenance.
9  Maintain the pump in good condition (use an authorised service agent). Keep the pump clean.
9If the supply cord is damaged, it must be replaced by a special cord or assembly available from the manufacturer or its service agents
9  Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9  Only use for pumping liquids under 35°C.
9  If pump is used to pump water from a well, drain or deep receptacle, take adequate precautions to stop persons or animals from
falling in.
9  Use the built-in handle to lower or raise the pump. It may be necessary to attach a suitable rope or pulley to the handle.
9  If the bottom of the water container is covered with sludge, sand, gravel or mud etc, suspend the pump or place it on a raised base to
operate above the solid matter. Sand and such substances will reduce working life of pump, and invalidate your warranty.
Recommended fuse rating
WPD235A 5Amp
WPS225A 13 Amp
WPD235A.V3, WPS225A.V3 Issue:2 13/03/23
Original Language Version
© Jack Sealey Limited
Refer to
instructions
9  The pump is to be located where flooding can not occur.
9In flood situations, user is responsible for ensuring that appropriate back-up procedures, alarms etc are correctly installed in case of
pump failure.
9  In swimming pools, fish ponds, etc, ensure location is clear of people and animals, including removal of fish from pond.
8This pump is not designed for continuous use in a fish pond or similar water feature or display.
8  DO NOT operate the pump if any parts are damaged or missing as this may cause failure and/or possible personal injury.
8DO NOT use the pump for any purpose other than for that which it is designed.
8DO NOT use to pump chemicals, fuels or salt water.
8DO NOT insert hands into the mouth of the pump as this could lead to injury.
8DO NOT use to pump septic tanks or settling pits. DO NOT pump any liquids other than water.
8DO NOT operate the pump out of water. The pump pick up area must be completely submerged during operation.
8DO NOT exceed the maximum submersible depth - see specifications.
8DO NOT operate the pump during freezing temperatures. DO NOT leave the pump in water that may freeze.
8DO NOT use in swimming pools if people could come into contact with the water whilst pump is in use. The pump must not be used
when people are in the water.
8DO NOT use for pumping sea water or inflammable, corrosive, explosive or dangerous liquids.
8DO NOT carry the pump by its electrical cable, or outlet pipe. Use the handle only.
9When not in use switch off pump and remove plug from power supply. Rinse pump, drain out any water and store in a frost free, safe
location.
WARNING! DO NOT allow uncontrolled discharge of contaminated water which would pollute the environment.
Children from age 8 years and above, persons with reduced physical, sensory or mental capabilities, those with lack of experience
and knowledge can use the appliance, if they have been given supervision or instruction concerning use of the appliance In a safe
way to understand the hazards involved. Children shall not play with the appliance. Cleaning and user maintenance on the
appliance shall not be maintained by children without supervision.
2. INTRODUCTION
WPD235A.V2: Manufactured from corrosion resistant materials with steel motor case and polypropylene base cover. Fitted with automatic cut-
out. Minimum water depth of 40mm. Designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks,
cisterns, baths and the general transfer of water and dense liquids.
WPS225A.V3: Manufactured from corrosion resistant materials with stainless steel body and steel motor case. Fitted with automatic cut-out.
Minimum water depth of 30mm. Designed for operation in dense and dirty water. Suitable for the effective drainage of cellars, sinks, cisterns,
baths and the general transfer of water and dense liquids.
3. SPECIFICATION
Model No’s:................................WPD235A.V2/WPS225A.V3
Cut-Out: .................................................................Automatic
Maximum Head:.......................................................8m/7.5m
Maximum Output/Min: ..............................217L/min/225L/min
Maximum Particle Size:..................................... 35mm/15mm
Maximum Water Depth:.....................................................7m
Minimum Water Depth:...................................... 40mm/30mm
Motor Power:.................................................................750W
Outlet OD:......................................................... 25mm/38mm
Supply:...........................................................................230V
4. BEFORE USE
4.1. Read all safety warnings and all instructions. Failure to follow all warnings and instructions may result in electric shock, re and/or
serious injury. Save all warnings and instructions for future reference.
4.2. The pump can be connected to any shock-proof plug which has been installed according to regulations in force.
WARNING! When the pump is to be used near swimming pools or garden ponds and in their area of protection, it must be
equipped with a PRCD (residual current circuit breaker) with a nominal trip current of max.30mA . The pump must not be
operated while people are in the swimming pool or in the garden pond. Please contact your electrician.
WARNING! (Important for your own security) Before starting to run your new submersible pump, please have the following items
checked by an electrician:
• Ground connection
• Zero conductor
• Fault current breaker switch must correspond the safety regulations in force in that region.
They must work faultlessly.
4.3. The electrical connections must be protected from moisture.
4.4. If there is danger of ooding, the electrical connections must be taken to higher ground.
4.5. Circulation of aggressive uids, as well as the circulation of abrasive materials must be avoided at all costs.
4.6. The submersible motor-driven pump must be protected from frost.
4.7. The pump must be protected from running dry.
4.8. Access on the part of children should also be prevented with appropriate measures.
4.9. These submersible pumps is designed for the circulation of water with a maximum temperature of 35° C. This pump may not be
used for other uids, especially motor fuels, cleaning uids, and other chemical products.
5. INSTALLATION
5.1. The submersible pump is installed as follows:
Original Language Version
© Jack Sealey Limited
Float
holder
WPD235A.V3, WPS225A.V3 Issue:2 13/03/23
• In a stationary position with xed pipeline or
• in a stationary position with a exible hose pipe.
Note: never install the pump by suspending it unsupported from its delivery pipe or power cable. The submersible pump must be
suspended from the specially provided handle or be placed on the bottom of the shaft.
5.2. To guarantee that the pump works properly, the bottom of the shaft must be kept free of sludge and dirt of all kinds. If the level of
water sinks too far, any sludge in the shaft will dry out quickly and stop the pump from starting up. Therefore it is necessary to
check the submersible motor pump regularly (by carrying out start-up tests).
5.3. The oater is adjusted in a way that the pump can immediately be started.
Note: The pump shaft should have minimum dimensions of 40 x 40 x 50 cm, so that the oating switch can move freely.
5.4. MAINS SUPPLY
5.4.1. Submersible pump is equipped with a shock-proof plug according to regulations. The pump is designed to be connected to a 230V - 50
Hz earthed socket. Make sure that the socket is sufciently secured (min. 6 Amp.) and is in excellent condition.
5.4.2. Important Note! If the mains cable or plug suffers any damage from external action, repairs to the cable should be serviced by a
qualied specialist using genuine spare parts.
5.5. Fit appropriate discharge pipe to pump outlet and secure with clip. Ensure the diameter of the discharge pipe is the same as, or
greater than, the outlet diameter. Asmaller pipe will adversely effect the pump flow rate.
6. OPERATION
6.1. After having read these instructions carefully, you can set your pump to work, after checking the following:
• Check if the pump rests on the ground of the shaft.
• Check if pressure cord has been attached properly.
• Check if electrical connection is to correct specication.
• Check if socket is in good condition.
• Make sure that water and humidity can never come into contact with the mains supply.
• Avoid pump running dry.
6.2. VENT THE PUMP BEFORE USE
6.2.1. Always ensure that the pump is vented properly before commissioning the pump. Tilting back and forth several times until no more air
bubbles appear, wait at least 15 seconds before starting pump.
6.3. ADJUSTING THE ON/OFF OPERATING POINT
6.3.1. The ON and OFF operating point of the oat switch can be set by adjusting the oat switch in its holder.
6.3.2. Before you put the pump into operation, please check the following:
• The oat switch must be installed so that the level of the ON operating point and the level of the OFF operating point can be reached
easily and with little force. To check this, place the pump in a vessel lled with water, raise the oat switch carefully by hand and then
lower it again. Note whether the pump switches on and off.
• Make sure that the distance between the oat switch head and the holder is not too small. Proper operation is not guaranteed if the
gap is too small.
• When you set the oat switch, make sure that it does not touch the base before the pump switches off.
CAUTION! RISK OF DRY-RUNNING.
6.4. The water into which the pump is placed will act as the motor cooling agent. For this reason the pump must remain submerged at all
times. Should the pump have to be used in shallow water DO NOT operate for more than 10 minutes. Failure to follow this rule will
damage the unit and will invalidate your warranty.
This appliance cannot be used by children or people who are physically, mentally or developmentally impaired, or people who lack
experience or knowledge, except in case these people receive instruction from a person responsible for their safety, a supervisor, or by
studying the preceding instructions concerning use of this appliance.
NOTE: Refer to Specification section to determine minimum clearance required if using pump in a restricted area i.e. well, etc.
7. MAINTENANCE
WARNING! With the exception listed below, all pump, float and electrical cable service maintenance and repair must only be
undertaken by an authorised service agent. Failure to observe this rule may be dangerous and will invalidate your warranty.
WARNING! Ensure the pump is disconnected from the mains power supply before attempting any service or maintenance.
7.1. When the pump is often transported in the course of operation, it should be cleaned out with clear water after every use.
7.2. In case of stationary installation, the function of the floating switch should be checked every 3 months.
7.3. All fibrous particles which may have built-up inside the pump housing should be removed with a water jet.
7.4. Every 3 months the shaft ground and as should be cleaned of mud.
7.5. Remove deposits on the floater with clear water.
7.6. Cleaning the impeller
7.6.1. If excessive deposits collect in the pump case you must dismantle the bottom part of the pump as follows:
1. Remove the intake cage from the pump case.
2. Clean the impeller with clear water.
Important! DO NOT put down or rest the pump on the impeller!
3. Re-assemble in reverse order
8DO NOT dismantle any other part of the unit.
8. STORAGE
8.1. Thoroughly clean the whole machine and its accessories.
8.2. Store out of the reach of children, in a stable and secure position, in a cool and dry place, avoid too high and too low temperatures.
8.3. Protect it from exposure to direct sunlight. Keep it in the dark, if possible.
8.4. Don’t keep it in plastic bags to avoid humidity build-up.
Original Language Version
© Jack Sealey Limited WPD235A.V3, WPS225A.V3 Issue:2 13/03/23
9. TROUBLESHOOTING
Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR
01284 75750 sales@sealey.co.uk www.sealey.co.uk
ENVIRONMENT PROTECTION
Recycle unwanted materials instead of disposing of them as waste.All tools, accessories and packaging should be sorted,
taken to a recycling centre and disposed of in a manner which is compatible with the environment. When the product
becomes completely unserviceable and requires disposal, drain any fluids (if applicable) into approved containers and
dispose of the product and fluids according to local regulations.
WEEE REGULATIONS
Dispose of this product at the end of its working life in compliance with the EU Directive on Waste Electrical and Electronic Equipment
(WEEE). When the product is no longer required, it must be disposed of in an environmentally protective way. Contact your local solid
waste authority for recycling information.
Note: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and component parts without prior
notice. Please note that other versions of this product are available. If you require documentation for alternative versions, please email or call
our technical team on technical@sealey.co.uk or 01284 757505.
Important: No Liability is accepted for incorrect use of this product.
Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim.
Original Language Version
© Jack Sealey Limited
REGISTER YOUR
PURCHASE HERE
Problem Causes Remedy
Pump does not start No mains supply
Float does not switch Check for mains supply
Bring oater to a higher position
No ow Inlet sieve is blocked
Pressure hose is bent Clean inlet
Reset hose
Pump does not switch off Floater can not sink down Place pump properly on the shaft, well etc.
oor
Insufcient ow Inlet sieve is clogged
Reduced pumping capacity due to dirty and
abrasive water
Clean inlet sieve
Clean pump and replace worn out parts
Pump shuts off after a short operating period Thermal cut out stops pump due to dirty water
Water too hot
Thermal cut out stops pump
Remove mains plug
Clean pump and shaft
Ensure that max. water temperature of 35°C
is not exceeded
WPD235A.V3, WPS225A.V3 Issue:2 13/03/23

This manual suits for next models

1

Other Sealey Water Pump manuals

Sealey WPS060 User manual

Sealey

Sealey WPS060 User manual

Sealey SDW50A User manual

Sealey

Sealey SDW50A User manual

Sealey RE83/840.V2 User manual

Sealey

Sealey RE83/840.V2 User manual

Sealey WPCD215 User manual

Sealey

Sealey WPCD215 User manual

Sealey TP6918 User manual

Sealey

Sealey TP6918 User manual

Sealey TP9424.V2 User manual

Sealey

Sealey TP9424.V2 User manual

Sealey TP6801 User manual

Sealey

Sealey TP6801 User manual

Sealey WPS062S User manual

Sealey

Sealey WPS062S User manual

Sealey WPS060.V2 User manual

Sealey

Sealey WPS060.V2 User manual

Sealey EWP40 User manual

Sealey

Sealey EWP40 User manual

Sealey WPW9355 User manual

Sealey

Sealey WPW9355 User manual

Sealey TP98 User manual

Sealey

Sealey TP98 User manual

Sealey WPD415.V2 User manual

Sealey

Sealey WPD415.V2 User manual

Sealey AK450DX User manual

Sealey

Sealey AK450DX User manual

Sealey WPD235P User manual

Sealey

Sealey WPD235P User manual

Sealey WPC100.V2 User manual

Sealey

Sealey WPC100.V2 User manual

Sealey PW12CC User manual

Sealey

Sealey PW12CC User manual

Sealey TP80 User manual

Sealey

Sealey TP80 User manual

Sealey AK4555D User manual

Sealey

Sealey AK4555D User manual

Sealey WPP3000S User manual

Sealey

Sealey WPP3000S User manual

Sealey TP6818 User manual

Sealey

Sealey TP6818 User manual

Sealey WPC100P User manual

Sealey

Sealey WPC100P User manual

Sealey WPP1750S User manual

Sealey

Sealey WPP1750S User manual

Sealey WPC100 User manual

Sealey

Sealey WPC100 User manual

Popular Water Pump manuals by other brands

Armstrong HEP Optimo S Installation and operating instructions

Armstrong

Armstrong HEP Optimo S Installation and operating instructions

Gast SOA Series Operation & maintenance manual

Gast

Gast SOA Series Operation & maintenance manual

GORMAN-RUPP PUMPS VS6A60-B Installation, operation, and maintenance manual with parts list

GORMAN-RUPP PUMPS

GORMAN-RUPP PUMPS VS6A60-B Installation, operation, and maintenance manual with parts list

Espa BASIC instruction manual

Espa

Espa BASIC instruction manual

HYDROO WDROO Series Operation manual

HYDROO

HYDROO WDROO Series Operation manual

Wilden A.025 Original Metal Series manual

Wilden

Wilden A.025 Original Metal Series manual

Resol FlowSol B Installation, Operation, Commissioning, Maintenance

Resol

Resol FlowSol B Installation, Operation, Commissioning, Maintenance

Rietschle PICOLONO VTE 3 operating instructions

Rietschle

Rietschle PICOLONO VTE 3 operating instructions

Flotec FPCP Series owner's manual

Flotec

Flotec FPCP Series owner's manual

Wolf Solar pump assembly 10 installation instructions

Wolf

Wolf Solar pump assembly 10 installation instructions

WilTec CTF-2800 operating instructions

WilTec

WilTec CTF-2800 operating instructions

Recreation Supply CC-34VC-50 Assembly instructions

Recreation Supply

Recreation Supply CC-34VC-50 Assembly instructions

SFA Sanicondens Mini v02 Operating & installation manual

SFA

SFA Sanicondens Mini v02 Operating & installation manual

Chicago Pneumatic CP 0020 Safety and operating instructions

Chicago Pneumatic

Chicago Pneumatic CP 0020 Safety and operating instructions

Pfeiffer Vacuum OKTA 6000 operating instructions

Pfeiffer Vacuum

Pfeiffer Vacuum OKTA 6000 operating instructions

GE UPK3 installation instructions

GE

GE UPK3 installation instructions

Pratissoli SH Series instruction manual

Pratissoli

Pratissoli SH Series instruction manual

Biral PrimAX RED Series Installation and operating instructions

Biral

Biral PrimAX RED Series Installation and operating instructions

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions