sebaKMT HL 50 User manual

Fehler! Kein Text mit angegebener Formatvorlage im Dokument.
1
User Guide
Bedienhandbuch
HL 50
Acoustic Leak Locator
Akustisches Leckortungsgerät
02 (02/2015) - EN/DE
83559
Mess- und Ortungstechnik
Measuring and Locating Technologies
Elektrizitätsnetze
Power Networks
Kommunikationsnetze
Communication Networks
Rohrleitungsnetze
Water Networks
Abwassernetze
Sewer Systems
Leitungsortung
Line Locating

2
Megger Limited Seba Dynatronic
Mess- und Ortungstechnik GmbH
Archcliffe Road
Kent CT17 9EN
T: +44 1304 502100
F: +44 1304 207342
E: uksales@megger.com
Dr.-Herbert-Iann-Str. 6
D - 96148 Baunach
T: +49 9544 68 – 0
F: +49 9544 22 73
E: sales@sebakmt.com
Hagenuk KMT
Kabelmesstechnik GmbH Megger USA
Röderaue 41
D - 01471 Radeburg / Dresden
T: +49 35208 84 – 0
F: +49 35208 84 249
E: sales@sebakmt.com
Valley Forge Corporate Centre
2621 Van Buren Avenue
Norristown, PA 19403 USA
T: +1 610 676 8500
F: +1 610 676 8610
SebaKMT
All rights reserved. No part of this handbook may be copied by photographic or other means unless SebaKMT
have before-hand declared their consent in writing. The content of this handbook is subject to change without
notice. SebaKMT cannot be made liable for technical or printing errors or shortcomings of this handbook.
SebaKMT also disclaims all responsibility for damage resulting directly or indirectly from the delivery, supply,
or use of this matter.

3
English 5
Safety 7
Function and Design 8
Technical Data and Accessories 10
Headphones 11
Energy Supply 11
Operation 12
Deutsch 15
Sicherheit 17
Funktion und Aufbau 18
Technische Daten und Zubehör 20
Kopfhörer 21
Energieversorgung 21
Gebrauch 22

4

5
English

6

7
Safety
This manual contains basic instructions for the commissioning and operation of the
device / system. For this reason, it is important to ensure that the manual is always
available to the authorised and trained operator. He needs to read the manual
thoroughly. The manufacturer is not liable for damage to material or humans due to non-
observance of the instructions and safety advices provided by this manual.
Locally applying regulations have to be observed!
xThe limits described under Technical Data may not be exceeded.
xDo not drop the device / the system’s components or subject it / them
to strong impacts or mechanical shocks.
xThe device / system must be in a technically perfect condition for
measurement.
xThe indicated degree of protection can only be ensured if plugs or the
provided protection caps are put in all sockets of the device.
xThe plugs of the supplied connection cables are only compliant to the
indicated degree of protection as long as they are plugged in. Plugs
which are not connected or which are connected in a wrong way are
not protected from water and dust ingress.
Check the contents of the package for completeness and visible damage right after
receipt. In the case of visible damage, the device must under no circumstances be taken
into operation. If something is missing or damaged, please contact your local sales
representative.
It is important to observe the generally applicable regulations of the country in which the
device will be operated, as well as the current national accident prevention regulations
and internal company directives (work, operating and safety regulations).
Use genuine accessories to ensure system safety and reliable operation. The use of
other parts is not permitted and invalidates the warranty.
Repair and maintenance work has to be carried out by SebaKMT or authorised service
partners using original spare parts only. SebaKMT recommends having the system
tested and maintained at a SebaKMT service centre once a year.
SebaKMT also offers its customers on-site service. Please contact your service centre if
needed.
The lithium batteries of the device are dangerous goods. The transport of the batteries
itselves and of devices which contain such batteries is subject to regulations based on
the UN Model Regulations “Transport of Dangerous Goods” (ST/SG/AC.10-1).
Please inform yourself about the transportation requirements and follow them when
shipping the device.
English
Safety precautions
Safety instructions
and warnings
Check contents
Working with products
from SebaKMT
Repair and
maintenance
Special transportation
requirements

8
Function and Design
The Hydrolux HL 50 by SebaKMT is an easy-to-use and handy device for acoustic leak
detection on water pipes.
The HL 50 comes with an integrated acoustic sensor. The pipe noise is recorded via the
probe tip, internally amplified, filtered (if needed) and played via wireless headphones.
At the same time, the measured noise level is shown on the display of the device.
During the measurement, the user can select from three frequency filter settings.
The probe tip can be removed. This way, prolongation sticks or other probes can be
installed.
Using the sensor socket, an external acoustic sensor can be connected to the HL 50,
e.g. a ground microphone.
Instead of wireless headphones, also corded headphones can be used.
The following picture shows the probe tip, sensor and the connection sockets of the
device.
Element Description
Probe tip (replaceable, thread M8)
Acoustic sensor of the device (not removable)
Sensor socket
for the connection of an external acoustic sensor (ground microphone or
similar)
Audio socket (3.5 mm)
for the connection of corded headphones
Function
Design

9
The following picture shows the control panel of the device.
Element Description
Display
On the screen you find the following information:
The currently measured level is displayed as a dimensionless numerical value
between 1-99.
The bar also reflects the current level. The arrow below the bar marks the
most recently saved measurement value.
Operating keys
Filter button
Select frequency filter (3 settings LOW / HIGH / ALL)
Volume buttons …
Increase / decrease headphone volume
(Attention: this ONLY applies to corded headphones, NOT to wireless
headphones)
I/O button
Long press … switches the device on / off
Short press … starts / stops the ongoing measurement:
headphones are activated / deactivated at the same time
English
34
ALL Current
Level
Frequency Filter
Headphones OFF

10
Technical Data and Accessories
The HL 50 is specified by the following technical parameters:
Parameter Value
Headphones Wireless headphones (864 MHz);
Connection socket for corded headphones
Sensor Internal piezo microphone
(noise recording via probe tip or other probe);
Connection socket for external microphone
Display LCD, 102 x 64 dots, transflective
Filter 3 settings selectable:
0 ... 540 Hz
0 ... 4000 Hz
540 ... 4000 Hz
Memory Last measured value
Battery 2 x AA 1.5 V or
2 x 1.2 V rechargeable NiMH (min. 1800 mAh)
Operating time >50 h
Operating temperature -10 °C … +50 °C (14 °F … +122 °F)
Storage temperature -25 °C … +70 °C (-13 °F … +158 °F)
Dimensions 90 x 185 x 60 mm
Weight 400 g (incl. standard probe tip and battery)
Degree of protection IP41
The standard scope of delivery includes:
Accessory part Description Art.Nr.
HLE 50 Leak detection device 138316193
WHP 863 Wireless headphones 138315814
Tastspitze Standard probe tip (thread M8) 820002715
Magnetadapter Magnet probe (thread M8) 110030010
VST 2 2 x prolongation stick (thread M8) 820003336
Transport case
The following accessories are available:
Accessory part Description Art.Nr.
PAM B-2 All-purpose piezo microphone; incl. connection cable 820013156
PAM W-2 Wind-shielded ground microphone;
incl. connection cable and handle bar 128310702
(continued on next page)
Technical data
Standard accessories
Optional accessories

11
Accessory part Description Art.Nr.
PAM T-3-1 Robust sensor-rod microphone for soft grounds;
incl. connection cable 1003846
LOG TP Tripod adaptor 128309877
AD S-20 Valve adaptor (Ø 20 mm) 810000357
AD S-42 Valve adaptor (Ø 40 mm) 810000358
Headphones
The HL 50 comes with wireless headphones. These have the following operating
elements:
ON / OFF … ON/OFF switch
TUNE … Frequency selection control dial
VOL … Volume control dial
Via the audio socket , any corded headphones can be connected to the HL 50.
After connecting the headphones, the HL 50 has to be restarted. The headphones are
recognised automatically by the device. While there are corded headphones connected,
the use of the wireless headphones is not possible.
The volume of the headphones can be adjusted via the buttons and .
After removing the corded headphones, the HL 50 does not automatically switch back to
the wireless headphones mode. The device needs to be restarted for this purpose.
Energy Supply
The device is delivered with the following batteries:
2 x 1.5 V AA LR6
Alternatively, rechargeable 1.2 V NiMH batteries can be used (min. 1800 mAh).
When the battery level is low, a flashing battery symbol appears at the top of the
display.
Empty batteries can be replaced. For this purpose, loosen the screw at the backside of
the device and remove the cover. Pay attention to the correct polarity when inserting the
new batteries. Then re-attach the cover and tighten the screw carefully.
Don´t overtighten!
Please act carefully and without violence at all times, in order to avoid
damaging the components.
Wireless headphones
Corded headphones
English

12
Operation
When conducting a measurement with the internal sensor, the noise is recorded with the
probe tip .
The probe tip can be removed. If needed, you can unscrew it (right-hand thread) and
replace it with another probe, or you can install the supplied prolongation sticks between
the probe tip and the sensor.
Via the 5-pole socket at the bottom side of the device, an external sensor can be
connected to the HL 50, e.g. the universal microphone PAM B-2. (There are more
sensors available from the optional accessories by SebaKMT.)
When connecting an external sensor, the HL 50 needs to be switched off. Pay attention
to the marks on the plug and the socket. The plug needs to lock tangibly.
When the HL 50 is switched on, it automatically recognises the external sensor. From
that moment, the values of the external sensor are indicated on the display.
Alternating between the internal and external sensor while operating the device is not
possible.
After removing the external sensor, the HL 50 does not automatically switch back to the
internal sensor. The device needs to be restarted for this purpose. Then the values of
the internal sensor are shown in the display again.
By clicking the button the user can switch between the three following
frequency filter settings during the measurement:
Designation Range Description
LO 0 ... 540 Hz High frequencies are cut;
(for operation as ground microphone)
HI 540 … 4000 Hz Low frequencies are cut;
(for operation as test rod directly on the pipe or
valve etc.)
ALL 0 ... 4000 Hz Broadband measurement without filter
Measurement using the
probe tip
Measurement using an
external sensor
Frequency filter

13
We recommend the following procedure in order to conduct a measurement:
Wireless headphones Corded headphones
xSwitch headphones on but don´t put
them on yet
xSet the headphones volume to „low“
(controller „VOL“ just above the
„MIN“ position); only put the
headphones on now
xSwitch the HL 50 on
with I/O-button
xAdjust the headphones to the correct
radio frequency (controller "TUNE")
xPress the I/O-button of the HL 50 in
order to "mute" the headphones;
the symbol appears in the display
xConnect headphones but don´t put them
on yet
xSwitch the HL 50 on
with I/O-button
xSet the volume to the lowest level via
the button ; only put the
headphones on now
xPress the I/O-button in order to "mute"
the headphones;
the symbol appears in the display
xSet the frequency filter to "ALL" with the button .
xIn order to conduct a measurement, press the I/O-button. The headphones are
reactivated and the recorded noise is played. The level of the noise is shown on the
display.
xChange the frequency filter if needed.
xBefore every relocation of the device resp. the external sensor, press the I/O-button.
The display freezes and the headphones switch to "mute".
How to conduct a
measurement
English

14

15
Deutsch

16

17
Sicherheit
Dieses Handbuch enthält elementare Hinweise zur Inbetriebnahme und Betrieb des
Gerätes / Systems. Daher muss sichergestellt sein, dass dieses Handbuch dem
autorisierten und geschulten Bedienpersonal jederzeit zugänglich ist. Das
Bedienpersonal hat das Handbuch genau zu lesen. Der Hersteller haftet in keinem Fall
für Schäden an Personen und Material, welche durch die Nichtbeachtung der in diesem
Handbuch enthaltenen Sicherheitshinweise entsteht.
Es sind die landesspezifischen Normen und Vorschriften zu beachten!
xDie in den technischen Daten angegebenen Grenzwerte dürfen auf
keinen Fall überschritten werden.
xDas Gerät ist / die Komponenten des Systems sind stoßempfindlich.
Nicht fallen lassen oder anderweitig belasten.
xNehmen Sie das Gerät / System nur in Betrieb, wenn es sich in
technisch einwandfreiem Zustand befindet.
xDie für das Gerät / die Einzelgeräte angegebenen Schutzgrade
bezüglich Feuchtigkeit und Staub können nur gewährleistet werden,
wenn in sämtliche Buchsen die zugehörigen Stecker eingesteckt sind,
oder die Buchsen mit den entsprechenden Schutzkappen abgedeckt
sind.
xDie Stecker der mitgelieferten Verbindungskabel erfüllen nur im
angeschlossenen Zustand die Kriterien des jeweils ausgewiesenen
Schutzgrades. In nicht oder nicht korrekt angeschlossene Stecker
kann Wasser und Staub eindringen.
Prüfen Sie den Lieferumfang unmittelbar nach Erhalt auf Vollständigkeit und äußerlich
sichtbare Beschädigungen. Geräte mit erkennbaren Schäden dürfen unter keinen
Umständen in Betrieb genommen werden. Sollte etwas fehlen oder beschädigt sein,
setzen Sie sich bitte umgehen mit Ihrem Vertriebspartner in Verbindung.
Zu beachten sind die allgemein gültigen Vorschriften des Landes, in dem das Gerät
betrieben wird sowie die bestehenden nationalen Vorschriften zur Unfallverhütung und
eventuell intern existierende Vorschriften (Arbeits-, Betriebs- und
Sicherheitsvorschriften) des Betreibers.
Originalzubehör dient der Systemsicherheit und Funktionssicherheit. Die Verwendung
anderer Teile ist unzulässig und führt zum Verlust der Gewährleistung.
Reparaturen und Wartungsarbeiten dürfen nur durch SebaKMT selbst oder autorisierte
Service-Partner und unter Verwendung von Originalersatzteilen durchgeführt werden.
SebaKMT empfiehlt, das System einmal jährlich in einem SebaKMT-Servicecenter
prüfen und warten zu lassen.
SebaKMT bietet seinen Kunden auch Vorort-Service. Bitte kontaktieren sie bei Bedarf
das für sie zuständigen Servicecenter.
Der Transport von Lithium-Batterien, sowie von Geräten, in denen solche Batterien oder
Akkus verbaut sind, ist durch Vorschriften geregelt, welche auf den
UN-Modellvorschriften für den Gefahrguttransport (UN Dokument ST/SG/AC.10-1)
basieren.
Informieren Sie sich über die Transportvorschriften und befolgen sie diese beim
Transport des Systems.
Deutsch
Sicherheits-
vorkehrungen
Warn- und
Sicherheitshinweise
Lieferumfang prüfen
Arbeiten mit Produkten
von SebaKMT
Reparatur und Wartung
Transport der Geräte

18
Funktion und Aufbau
Das Hydrolux HL 50 von SebaKMT ist ein leicht zu bedienendes, handliches Gerät zur
akustischen Leckortung an Wasserleitungen.
Das HL 50 verfügt über einen integrierten akustischen Sensor. Das Rohrgeräusch wird
über die Tastspitze aufgenommen, intern verstärkt, bei Bedarf gefiltert und über die
Funkkopfhörer wiedergegeben. Der gemessene Geräuschpegel wird gleichzeitig auf
dem Display des Gerätes angezeigt.
Der Nutzer kann während der Messung zwischen drei Frequenzfiltereinstellungen
wählen.
Die Tastspitze des HL 50 ist demontierbar. Auf diese Weise können Verlängerungen
oder andere Tastköpfe eingesetzt werden.
Über die Sensorbuchse kann ein externer akustischer Sensor an das HL 50
angeschlossen werden, zum Beispiel ein Bodenmikrofon.
Anstelle der Funkkopfhörer können kabelgebundene Kopfhörer verwendet werden.
Das folgende Bild zeigt Tastspitze, Sensor und Anschlussbuchsen des Gerätes.
Element Beschreibung
Tastspitze (austauschbar, Gewinde M8)
akustischer Sensor des Gerätes (nicht demontierbar)
Sensorbuchse
für den Anschluss eines externen akustischen Sensors (Bodenmikrofon o.ä.)
Kopfhörerbuchse (3,5 mm)
für den Anschluss kabelgebundener Kopfhörer
Funktion
Aufbau

19
Das folgende Bild zeigt das Bedienfeld des Gerätes.
Element Beschreibung
Anzeige
Auf dem Bildschirm finden Sie folgende Informationen:
Der aktuell gemessene Pegel wird als dimensionsloser Zahlenwert zwischen
1-99 angezeigt.
Der Balken spiegelt ebenfalls den aktuellen Pegel wider. Der Pfeil unterhalb
des Balkens markiert den zuletzt gespeicherten Messwert.
Bedientasten
Filter-Taste
Frequenzfilter wählen (3 Stufen LOW / HIGH / ALL)
Lautstärke-Tasten …
Kopfhörerlautstärke vermindern / erhöhen
(Achtung: gilt NUR für kabelgebundene Kopfhörer, NICHT für Funkkopfhörer)
I/O-Taste
langes Drücken … schaltet das Gerät ein / aus
kurzes Drücken … startet / stoppt die laufende Messung
gleichzeitig werden die Kopfhörer aktiviert / deaktiviert
Deutsch
34
ALL aktueller
Pegel
Kopfhörer AUS
Frequenzfilter

20
Technische Daten und Zubehör
Das HL 50 wird durch folgende technische Parameter spezifiziert:
Parameter Wert
Sensor interner piezokeramischer Sensor
(Tonaufnahme über Tastspitze oder anderen Tastkopf);
externes Mikrofon anschließbar
Kopfhörer Funkkopfhörer (864 MHz);
zusätzl. Anschlussbuchse für Kabelkopfhörer
Display LCD, 102 x 64 Punkte, transflektiv
Frequenzfilter 3 Stufen wählbar:
0 ... 540 Hz
0 ... 4000 Hz
540 ... 4000 Hz
Speicher letzter Pegel
Batterie 2 x AA 1.5 V oder
2 x 1.2 V NiMH-Akku (min. 1800 mAh)
Betriebsdauer >50 h
Betriebstemperatur -10 °C … +50 °C
Lagertemperatur -25 °C … +70 °C
Maße 90 x 185 x 60 mm
Gewicht 400 g (inkl. Standard-Tastspitze und Batterien)
Schutzgrad IP41
Der Standard-Lieferumfang umfasst:
Zubehörteil Beschreibung Art.Nr.
HLE 50 Wasserlecksuchgerät 138316193
WHP 863 Funkkopfhörer 138315814
Tastspitze Standard-Tastkopf (Gewinde M8) 820002715
Magnetadapter magnetischer Tastkopf (Gewinde M8) 110030010
VST 2 2 x Verlängerungsstab (Gewinde M8) 820003336
Transporttasche
Das folgende Zubehör ist optional erhältlich:
Zubehörteil Beschreibung Art.Nr.
PAM B-2 aktives Universalmikrofon mit Piezosensor;
inkl. Kabelsatz 820013156
PAM W-2 windgeschütztes Bodenmikrofon;
inkl. Kabelsatz und Tragestab 128310702
(Fortsetzung auf der nächsten Seite)
Technische Daten
Standardzubehör
Optionales Zubehör
Table of contents
Languages:
Other sebaKMT Measuring Instrument manuals