Secabo TC1 User manual

OPERATING MANUAL
for the heat press
SECABO TC1
Congratulations on the purchase of your Secabo heat press!
Please read this operating manual carefully to ensure a smooth production launch with your new
device.
Any type of reproduction of this operating manual requires the written permission of Secabo
GmbH. Modifications to and errors in the technical data and/or product characteristics are
reserved.
Secabo GmbH accepts no liability for any direct or indirect damages resulting from the use of this
product.
Version 1.1 (29.07.2019)
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com

Brief overview
Secabo TC1 Heat Press
With its TC1, Secabo offers the perfect heat press for taking first steps in the world of textile
finishing and other transfer techniques. Thanks to its compact dimensions, the TC1 is also suitable
as a mobile press in the area of merchandising for sports, bands and other events. The Secabo
TC1 features a digital controller, which allows for pre-setting the transfer's time and temperature.
An acoustic signal sounds after the set time has expired. The contact pressure can be set using a
hand wheel on the upper side of the heat plate. The pressing process is initiated by closing the
press lever. The large opening angle allows for comfortable preparation of the transfer objects on
the base plate. The TC1 is equipped with a work surface of 15cm x 15cm and a heat plate with a
power consumption of 700W.
● affordable heat press for beginners
● mobile press for on-site use at events and merchandising
● large opening angle
● digital controller for temperature, time
● high heat output
Safety Precautions
Please read the information and safety precautions carefully prior to first commissioning of the
device!
● Never reach inside the heat press with your hands when it is connected to the power
supply, especially if it is switched on and heated up – danger of burns!
● Never open the casing and do not make any modifications to the unit yourself.
● Should it be necessary to open the heat plate cover upon explicit request by Secabo's
customer service team, it is recommended you wear respiratory protection and only touch
the insulation wool located therein using gloves. Possible disposal of the insulation wool
should only be done inside a closed bag.
● Ensure that neither liquids nor metal objects reach the inside of the heat press.
● Make sure you use a grounded wall socket. Keep in mind that a heat press may only be
operated using a wall socket equipped with a ground fault circuit interrupter.
● Disconnect the heat press from the power supply when it's not in use.
● Always ensure that the heat press is out of reach of children during operation and never
leave the device unsupervised when switched on.
● Make sure the unit is only used in dry rooms.
If you cannot comply with one or more of the aforementioned safety rules, or if you are
unsure as to whether you're in compliance with all of the points, please contact our
technical support.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com

Machine description
a. Heat plate
b. Press lever
c. Digital controller for temperature, time
d. Power plug and power switch
e. Base plate
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com

Controller
The central controller allows for setting the desired temperature (°C and °F), as well as the press
duration in seconds.
Operation
● Use the the supplied power cord to connect the heat press to a 230V socket.
● The red toggle switch turns the press ON.
● Press the SET Button in the Temperature field to set the desired temperature using the
arrow keys. Confirm the value by pressing the SET button again.
● Press the SET Button in the Time field to set the desired pressing time using the arrow
keys. Confirm the value by pressing the SET button again.
● The press will now heat up to the set temperature.
● Now you're ready to perform your first transfers. The clock starts counting as soon as the
press is closed with the press lever.
● 3 seconds before the set time runs out, a warning signal is sounded.
● After the time has elapsed, the press must be opened manually.
● You can adjust the contact pressure by turning the large hand screw at the top of the press
to increase or decrease the distance the lever travels. Turning the knob clockwise
decreases the contact pressure, while turning it counterclockwise increases it.
● No settings can be changed at the controller while a press operation is in progress.
Note: Please keep in mind that it takes some time for the press to cool off after it is
switched off.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com

Maintenance and cleaning
All maintenance work must be carried out with the press switched off and cooled off, no
exceptions! First, remove the plug from the wall socket. Only perform maintenance work after
consultation with our technical support team.
The press should be cleaned regularly using a soft cloth and a mild household cleaner to remove
adhesive residues, etc. Do not use scouring sponges, solvents or gasoline!
Recommended times and temperatures
These values should only be considered as guideline values, may vary depending on the material
and must be checked before pressing.
Material
temperature
Pressure
Press duration
Flock film
170°C - 185°C
low-medium
25s
Flex film
160°C - 170°C
medium-high
25s
Sublimation flex
180°C - 195°C
medium-high
10s - 35s
Sublimation on
mugs
200°C
medium-high
150s - 180s
Sublimation on tiles
200°C
high
120s - 480s
(depends on the thickness of the
material)
Sublimation on
puzzles
200°C
low-medium
25s
Sublimation on
mouse pads
200°C
medium
20s - 40s
Sublimation on
garments
200°C
medium-high
30s - 50s
Sublimation on
metal plates
200°C
high
10s - 50s
(depends on the thickness of the
material)
Important note: You should perform your own tests with the respective transfer materials
and carrier media prior to each production. The aforementioned values, as well as any
manufacturer specification merely serve as indications. Washing resistance and behavior
during the transfer must be determined by performing your own tests.
No guarantee can be derived from the recommended values. It is always the user's
responsibility to determine and apply the correct settings for his specific conditions.
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com

Note on garment finishing processes: After the press operation, garments must cool off
before any carrier media can be pulled off the transfer material. The hot glue in the transfer
material doesn't develop its adhesive strength until cooled off. If the glue does not stick in
its cold state, this may indicate that the pressing procedure was too cold or too short.
Technical data
Heat press
SECABO TC1
Type
manual clam press
Working area size
15cm x 15cm
Max. temperature
255°C
Max. preset time
999s
Max. working pressure
500g/cm²
Pressure setting
Height-adjustment of the heat plate via hand
wheel
Power supply
230V / 50Hz - 60Hz, 700W
Environment
+ 5°C - +35°C / 30% - 70% relative humidity
Weight
11kg
Dimensions (W x H x D)
16cm x 30cm x42cm

Declaration of conformity - Statement of Conformity
We hereby declare under our sole responsibility that the product referred
to in "technical data" complies with the provisions of the following
directives and standards:
We herewith declare under sole responsibility that the under „technical
data“ mentioned product meet the provisions of the following EC
Directives and Harmonized Standards:
● EG-Richtlinien / EC Directives:
● 2014/35 / FG Establishment Directive
● 2014/35/EC Low Voltage Directive
● 98/37/EC Directive on machinery (2006/42/EC from 12/29/2009)
● 98/37/EC Directive on machinery (from 2009-12-29: 2006/42/EC)
● Norm / Standard: EN 60204-1:2006
Technische Dokumente bei / Technical documents at:
Secabo GmbH, Hochstatt 6-8, 85283 Wolnzach, Germany
Dipl. Ing. Fabian Franke
Dipl. Ing.(FH) Bernhard Schmidt
Secabo GmbH Hochstatt 6-8 85283 Wolnzach Alemania [email protected] www.secabo.com
Table of contents
Other Secabo Power Tools manuals

Secabo
Secabo TB7 User manual

Secabo
Secabo TC5 Smart User manual

Secabo
Secabo TMUG User manual

Secabo
Secabo TC5 Smart User manual

Secabo
Secabo TCC SMART User manual

Secabo
Secabo TS7 User manual

Secabo
Secabo TC5 Smart User manual

Secabo
Secabo TS-38 User manual

Secabo
Secabo TM5 User manual

Secabo
Secabo TM2 User manual