1 of 4
QUICK START GUIDE
2Unlatch and swing open door
of unit for wiring and setup.
What’s what?
Important components labeled
Unit shown with door fully open.
Internal wiring not shown for clarity.
Ascent Unit 12-V AC/DC Adapter
(PS-12DC1)
Model 25-C2
Power and Relay Terminals
For wiring to power and gate operator
and/or door opener. See Page 2.
Relay Status LEDs
Relay is active when lit.
Antenna Jacks
SIM Card
Status and Event Terminals
For wiring to check gate status and
for request-to-exit devices. See Page 3.
Wiring Glands
4G LTE Antenna
Wiegand Device Terminals
For wiring to Wiegand-compatible devices.
See Page 4.
1Carefully unpack box and make sure you have all items
shown below. (Screwdriver not shown)
Continued on next page...
WARNING!
AUTOMATIC GATES CAN CAUSE
SERIOUS INJURY OR DEATH!
ALWAYS CHECK that the GATE PATH
IS CLEAR BEFORE OPERATING!
Reversing or other safety devices
SHOULD ALWAYS BE USED!

STOP!
This is a cellular accessory for a gate/door,
so an uninterrupted cellular connection
CANNOT BE GUARANTEED.
An emergency egress or primary entry
mechanism SHOULD ALWAYS BE USED
(transmitter, fire box, mechanical release).
Consult with your dealer, distributor, and/or
system designer for more information.

IMPORTANT!
r
Ascent WILL NOT WORK until the
activation process is COMPLETE!
Follow the Activation Guide or call
Summit Control at (844) 259-8265 to
activate your unit.
RELAY A
J4
RELAY B
J5
12–24 VAC/DC
POWER
J3 J8 J9 J12
DIGITAL INPUTS
2 of 4
QSG-25C2-EN Rev. G (5/2019)
© 2019 Security Brands, Inc. All rights reserved.
3Connect wires
Feed wires through cable gland(s)
on unit and connect as shown
using included screwdriver.
Excessive force can damage unit.
Tighten cable-gland locknut(s).
Ascent Power and Relay Terminals
12–24 VAC/DC
POWER
Gate Operator / Door Opener
POS. (+)
NEG. (–)
COM
RADIO
COM
REVERSE LOOP
COM
OPEN
STOP
CLOSE
OR
FREE EXIT
COM
+–
N/C
COM
N/O
N/C
COM
N/O
POS. (+)
NEG. (–)
GND
# 1
GND
# 2
GND
# 3
Third-Party 12–24-VAC/DC
Power Source
Model 25-C2
QUICK START GUIDE
Now follow the Activation Guide to create
an account and begin using Ascent.
INSTALLATION COMPLETE!
N
Before going forward,
double check wiring and
ensure unit has power!
For additional wiring
options, see Page 3.
STOP!

If you will not be using the 12-V AC/DC adapter,
please go to Page 4 and follow the procedure,
Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage unit!
CAUTION!

Consult gate operator or
door opener manual for
exact connections.
Terminals vary widely
across manufacturers
and models.
Relay B can be wired to a second device
in the same manner.
5Close and latch door of unit.
Additional wiring diagrams
can be found on Page 3.
12-V AC/DC Adapter
(Model PS-12DC1 included)
The GROUND terminal is optional unless
required by local code(s). If using, please
connect to earth ground or equivalent.
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
4Tighten cable-gland locknut(s).
3 of 4
QUICK START GUIDE Model 25-C2
The Status Terminals are designed for
low voltage (3 V or less). Check the
voltage on your status wires before
connecting. If it is above 3 V, you will
need to contact Technical Support.
Exceeding 3 V can damage unit!
CAUTION!

J7
GATE 1
J13
GATE 2 EVENT
J6
AStatus Check
Wiring to enable Gate Status Check
(if equipped with limit switches)
Open Limit Switch
Close Limit Switch
Optional
wire
splices
N/C
N/C
Gate Operator
BEvent Input
Wiring for accessories such as a request-to-exit device
Ascent Status and
Event Terminals
GND
N/O
COM
N/O
COM
N/O
CLOSE
GND
OPEN
CLOSE
GND
OPEN
J7
GATE 1
J13
GATE 2 EVENT
J6
Ascent Status and Event Terminals
CLOSE
GND
OPEN
CLOSE
GND
OPEN
Request-to-Exit
(S-RTE-P is shown)
GND
N/O
Gate Status Check WILL NOT WORK
with a decoder!
YOU MUST USE A DRY CONTACT!
IMPORTANT!
r
4 of 4
3a Connect wires to unit as shown in
Step 3.
3b Connect wires to your power source,
making sure you connect positive to
positive and negative to negative.
CAUTION!

Double check that you’ve wired from
positive on Ascent to positive on your
power source and negative on Ascent to
negative on your power source.
Reverse polarity can damage unit!
Using a
Third-Party
Power Source
(Optional)
IMPORTANT!
r
If you would like to use a third-party
power source, such as solar, verify that
it conforms to the following specs:
Input 12–24 VAC/DC
no more than 10% beyond this range
Current Draw less than 260 mA @ 12 VDC
less than 160 mA @ 24 VDC
QUICK START GUIDE Model 25-C2
?NEED HELP Call (844) 259-8265
Email [email protected]
We are available Mon–Fri / 8am–5pm Central
QSG-25C2-EN Rev. G (5/2019)
© 2019 Security Brands, Inc. All rights reserved.
If mounting Ascent inside a metal enclosure, the
4G LTE Antenna Extension Kit
(p/n 16-ANTX-1)
should be purchased and installed.
Failure to do so may result in NO SIGNAL!
IMPORTANT!
r
CWiegand Device
Wiring for Wiegand devices
J15 J16 J19 J18
Wiegand Device
WIEGAND INPUTS
Ascent Wiegand Device Terminals
+12V
GND
LED 1
LED 2
DATA 0
DATA 1
GND
LED 2
LED 1
DATA 0
DATA 1
DATA 0
DATA 1
+12V
GND
LED 2
LED 1
+12V
DOOR/READER A
WIEGAND 1
DOOR/READER B
WIEGAND 2
Disconnect power to Ascent before
connecting Wiegand devices.
Failure to disconnect power can
damage unit!
CAUTION!


This manual suits for next models

1

Other Security Brands Intercom System manuals

Security Brands ASCENT X1 User manual

Security Brands

Security Brands ASCENT X1 User manual

Security Brands 14-R433 User manual

Security Brands

Security Brands 14-R433 User manual

Security Brands Ascent M1 User manual

Security Brands

Security Brands Ascent M1 User manual

Security Brands Edge E3 User manual

Security Brands

Security Brands Edge E3 User manual

Security Brands Ascent M7 User manual

Security Brands

Security Brands Ascent M7 User manual

Security Brands ASCENT X1 User manual

Security Brands

Security Brands ASCENT X1 User manual

Security Brands ASCENT K2 User manual

Security Brands

Security Brands ASCENT K2 User manual

Security Brands Ridge RTE 14-RTE433 User manual

Security Brands

Security Brands Ridge RTE 14-RTE433 User manual

Security Brands Ridge 2.0 User manual

Security Brands

Security Brands Ridge 2.0 User manual

Security Brands ADVANTAGE DKLP 19-100 User manual

Security Brands

Security Brands ADVANTAGE DKLP 19-100 User manual

Security Brands Edge E4 User manual

Security Brands

Security Brands Edge E4 User manual

Security Brands ASCENT X1 User manual

Security Brands

Security Brands ASCENT X1 User manual

Security Brands Edge E2 User manual

Security Brands

Security Brands Edge E2 User manual

Security Brands Edge E1 User manual

Security Brands

Security Brands Edge E1 User manual

Security Brands RIDGE 2.0 User manual

Security Brands

Security Brands RIDGE 2.0 User manual

Security Brands Ascent M2 Series User manual

Security Brands

Security Brands Ascent M2 Series User manual

Popular Intercom System manuals by other brands

Dormakaba 8900 T installation instructions

Dormakaba

Dormakaba 8900 T installation instructions

DKS 1814 owner's manual

DKS

DKS 1814 owner's manual

Cannon Security Products DV01P user manual

Cannon Security Products

Cannon Security Products DV01P user manual

Guinaz G1250 installation guide

Guinaz

Guinaz G1250 installation guide

Aiphone GT-2C Operation manual

Aiphone

Aiphone GT-2C Operation manual

Aiphone JP-DA installation manual

Aiphone

Aiphone JP-DA installation manual

urmet domus 1083 Programming guide

urmet domus

urmet domus 1083 Programming guide

NICOR Prime Chime Plus PRCP2 installation instructions

NICOR

NICOR Prime Chime Plus PRCP2 installation instructions

Panasonic VL-SV72 operating instructions

Panasonic

Panasonic VL-SV72 operating instructions

Bticino 367811 Instructions for use

Bticino

Bticino 367811 Instructions for use

CyberData VoIP Intercom 010935F Operation guide

CyberData

CyberData VoIP Intercom 010935F Operation guide

golmar EL632/G+/48 Installer manual

golmar

golmar EL632/G+/48 Installer manual

Zennio Z41 COM Configuration guide

Zennio

Zennio Z41 COM Configuration guide

ELRO VD52A instruction manual

ELRO

ELRO VD52A instruction manual

Gyration Cyberview3000 user manual

Gyration

Gyration Cyberview3000 user manual

Telex RadioCom BTR-500/600C operating instructions

Telex

Telex RadioCom BTR-500/600C operating instructions

Slinex DESIGN DIRECT ML-16 user manual

Slinex

Slinex DESIGN DIRECT ML-16 user manual

Toa EXES 6000 CP-66 Installation handbook

Toa

Toa EXES 6000 CP-66 Installation handbook

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.