Security Brands ASCENT K2 User manual

1 of 4
Model 25-K2
QUICK START GUIDE
2Unlock and open front panel
of unit for wiring and setup. Ascent Camera
For automatic and on-demand photo capture
Power and Relay Terminals
For wiring to power and gate operator
and/or door opener. See Page 2.
Relay Status LEDs
Relay is active when lit.
Antenna Cables
SIM Card
Status and Event Terminals
For wiring to check gate status and for
request-to-exit devices. See Page 3.
Wiegand Device Terminals
For wiring to Wiegand-compatible devices.
See Page 4.
Unit shown with front panel fully open.
Internal wiring not shown for clarity.
Ascent Unit Key Carriage Bolt
( 4x )
Hex Nut
( 4x )
12-V AC/DC Adapter
(PS-12DC1)
1Carefully unpack box and make sure you have all items
shown here. (Screwdriver not shown) What’s what?
Important components labeled
Please use all four screws when mounting unit to pedestal. Leave “hockey puck” antenna
in place, even if using extension. Seal any holes or gaps created in unit enclosure.
Failure to follow instructions can damage unit!
CAUTION!

Continued on next page...
STOP!
This is a cellular accessory for a gate/door,
so an uninterrupted cellular connection
CANNOT BE GUARANTEED.
An emergency egress or primary entry
mechanism SHOULD ALWAYS BE USED
(transmitter, fire box, mechanical release).
Consult with your dealer, distributor, and/or
system designer for more information.

IMPORTANT!
r
Ascent WILL NOT WORK until the
activation process is COMPLETE!
Follow the Activation Guide or call
Summit Control at (844) 259-8265 to
activate your unit.
WARNING!
AUTOMATIC GATES CAN CAUSE
SERIOUS INJURY OR DEATH!
ALWAYS CHECK that the GATE PATH IS
CLEAR BEFORE OPERATING!
REVERSING or other SAFETY DEVICES
SHOULD ALWAYS BE USED!

© 2020 Security Brands, Inc. All rights reserved. QSG-25K2-EN Rev. F (6/2020)
2 of 4
Model 25-K2
QUICK START GUIDE
RELAY A
J4
RELAY B
J5
12–24 VAC/DC
POWER
J3 J8 J9 J12
DIGITAL INPUTS
4Close and lock front panel.
Now follow the Activation Guide to create
an account and begin using Ascent.
INSTALLATION COMPLETE!
N
Before going forward,
double check wiring and
ensure unit has power!
For additional wiring
options, see Page 3.
STOP!

If you will not be using the 12-V AC/DC adapter,
please go to Page 4 and follow the procedure,
Using a Third-Party Power Source.
Do not exceed 24 VAC/DC! Failure to choose a
compatible power source can damage unit!
CAUTION!

Ascent Power and Relay Terminals
12–24 VAC/DC
POWER
Gate Operator / Door Opener
POS. (+)
NEG. (–)
COM
RADIO
COM
REVERSE LOOP
COM
OPEN
STOP
CLOSE
OR
Relay B can be wired to a second device
in the same manner.
FREE EXIT
COM
N/C
COM
N/O
N/C
COM
N/O
POS. (+)
NEG. (–)
GND
# 1
GND
# 2
GND
# 3
Third-Party 12–24-VAC/DC
Power Source
12-V AC/DC Adapter
(Model PS-12DC1 included)
The GROUND terminal is optional unless
required by local code(s). If using, please
connect to earth ground or equivalent.
+–
Consult gate operator or
door opener manual for
exact connections.
Terminals vary widely
across manufacturers
and models.
3Connect wires
Feed wires through back of unit
and connect as shown using
included screwdriver.
Excessive force can damage unit.
If plugging into duplex outlet,
remove screw from outlet plate,
and secure with included screw.
Additional wiring diagrams
can be found on Pages 3 and 4.
3 of 4
Model 25-K2
QUICK START GUIDE
J7
GATE 1
J13
GATE 2 EVENT
J6
AStatus Check
Wiring to enable Gate Status Check
(if equipped with limit switches)
Open Limit Switch
Close Limit Switch
Optional
wire
splices
N/C
N/C
Gate Operator
BEvent Input
Wiring for accessories such as a request-to-exit device
Ascent Status and
Event Terminals
GND
N/O
COM
N/O
COM
N/O
CLOSE
GND
OPEN
CLOSE
GND
OPEN
The Status Terminals are designed for
low voltage (3 V or less). Check the
voltage on your status wires before
connecting. If it is above 3 V, you will
need to contact Technical Support.
Exceeding 3 V can damage unit!
CAUTION!

Gate Status Check WILL NOT WORK
with a decoder!
YOU MUST USE A DRY CONTACT!
IMPORTANT!
r
J7
GATE 1
J13
GATE 2 EVENT
J6
Ascent Status and Event Terminals
CLOSE
GND
OPEN
CLOSE
GND
OPEN
Request-to-Exit
(58-RTE-P is shown)
GND
N/O
© 2020 Security Brands, Inc. All rights reserved. QSG-25K2-EN Rev. F (6/2020)
4 of 4
Model 25-K2
QUICK START GUIDE
?NEED HELP Call (972) 474-6422
Email [email protected]
We are available Mon–Fri / 8am–5pm Central
3a Connect wires to unit as shown in
Step 3.
3b Connect wires to your power source,
making sure you connect positive to
positive and negative to negative.
CAUTION!

Double check that you’ve wired from
positive on Ascent to positive on your
power source and negative on Ascent to
negative on your power source.
Reverse polarity can damage unit!
Using a
Third-Party
Power Source
(Optional)
IMPORTANT!
r
If you would like to use a third-party
power source, such as solar, verify that
it conforms to the following specs:
Input 12–24 VAC/DC
no more than 10% beyond this range
Current Draw less than 260 mA @ 12 VDC
less than 160 mA @ 24 VDC
We recommend mounting Ascent on a
gooseneck pedestal using included hardware.
If using alternate mounting, the
4G LTE Antenna Extension Kit
(p/n 16-ANTX-1)
should be purchased and installed.
Failure to do so may result in NO SIGNAL!
IMPORTANT!
r
CWiegand Device
Wiring for Wiegand devices
J15 J16 J19 J18
Wiegand Device
WIEGAND OUTPUTS
Ascent Wiegand Device Terminals
+12V
GND
LED 1
LED 2
DATA 0
DATA 1
GND
LED 2
LED 1
DATA 0
DATA 1
DATA 0
DATA 1
+12V
GND
LED 2
LED 1
+12V
DOOR/READER A
WIEGAND 1
DOOR/READER B
WIEGAND 2
Disconnect power to Ascent before
connecting Wiegand devices.
Failure to disconnect power can
damage unit!
CAUTION!


This manual suits for next models

1

Other Security Brands Intercom System manuals

Security Brands Edge E3 User manual

Security Brands

Security Brands Edge E3 User manual

Security Brands Edge E4 User manual

Security Brands

Security Brands Edge E4 User manual

Security Brands Edge E1 User manual

Security Brands

Security Brands Edge E1 User manual

Security Brands Ascent M2 Series User manual

Security Brands

Security Brands Ascent M2 Series User manual

Security Brands ASCENT X1 User manual

Security Brands

Security Brands ASCENT X1 User manual

Security Brands 25-C2 User manual

Security Brands

Security Brands 25-C2 User manual

Security Brands Ascent M1 User manual

Security Brands

Security Brands Ascent M1 User manual

Security Brands ASCENT X1 User manual

Security Brands

Security Brands ASCENT X1 User manual

Security Brands Ridge RTE 14-RTE433 User manual

Security Brands

Security Brands Ridge RTE 14-RTE433 User manual

Security Brands ADVANTAGE DKLP 19-100 User manual

Security Brands

Security Brands ADVANTAGE DKLP 19-100 User manual

Security Brands 14-R433 User manual

Security Brands

Security Brands 14-R433 User manual

Security Brands Ridge 2.0 User manual

Security Brands

Security Brands Ridge 2.0 User manual

Security Brands Ascent M7 User manual

Security Brands

Security Brands Ascent M7 User manual

Security Brands Edge E2 User manual

Security Brands

Security Brands Edge E2 User manual

Security Brands RIDGE 2.0 User manual

Security Brands

Security Brands RIDGE 2.0 User manual

Security Brands ASCENT X1 User manual

Security Brands

Security Brands ASCENT X1 User manual

Popular Intercom System manuals by other brands

CDVI 2Easy CDV4796KP-DX manual

CDVI

CDVI 2Easy CDV4796KP-DX manual

Alcad TCB-010 manual

Alcad

Alcad TCB-010 manual

Akuvox X915S Configuration guide

Akuvox

Akuvox X915S Configuration guide

Conrad 552517 operating instructions

Conrad

Conrad 552517 operating instructions

Videx Audiokit 4K Series quick start guide

Videx

Videx Audiokit 4K Series quick start guide

urmet domus Alpha iPerCom 1168 Installation booklet

urmet domus

urmet domus Alpha iPerCom 1168 Installation booklet

Clare Controls Clare Video Doorbell quick start guide

Clare Controls

Clare Controls Clare Video Doorbell quick start guide

Commax CDV-43N user manual

Commax

Commax CDV-43N user manual

ABB Video Outdoor Station quick guide

ABB

ABB Video Outdoor Station quick guide

Aiphone JF-1MD Installation & operation manual

Aiphone

Aiphone JF-1MD Installation & operation manual

ViziT MK-405 Operating	 instruction

ViziT

ViziT MK-405 Operating instruction

ACT CONFIGURING ACTPRO200 manual

ACT

ACT CONFIGURING ACTPRO200 manual

Xingtel Xiamen Electronics CL-3684 user manual

Xingtel Xiamen Electronics

Xingtel Xiamen Electronics CL-3684 user manual

golmar ART 4/G2+ Monitor quick guide

golmar

golmar ART 4/G2+ Monitor quick guide

suprema BioLite Net installation guide

suprema

suprema BioLite Net installation guide

Digital Acoustics INT-IP-2GANG Getting started guide

Digital Acoustics

Digital Acoustics INT-IP-2GANG Getting started guide

AES 603AB Installation & user manual

AES

AES 603AB Installation & user manual

Amphenol Advance IR TSCAN-750 user manual

Amphenol

Amphenol Advance IR TSCAN-750 user manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.