Security Brands RTE P Guide

Installation and Use MANUAL
Touchless Request-to-Exit Station
RTE P
58-RTE-P


Security Brands, Inc. | Page 1
RTE P Touchless Request-to-Exit Station | Installation and Use Manual
Security Brands, Inc. Two-Year Limited Warranty
This Warranty Applies To:
Products branded as Security Brands, Inc., American Access Systems, and Summit Access Control
What Is Covered:
Any defects in materials or workmanship
Coverage Period:
Two years from date of purchase
What We Will Do:
If your Security Brands, Inc. (SBI), American Access Systems (AAS), or Summit Access Control (SAC) product is defective
and returned within two years of purchase, well will repair, or at our option, replace the unit at no charge to you. If we
repair your SBI, AAS, or SAC product, we may use new or reconditioned parts. If we choose to replace your SBI, AAS, or SAC
product, we may replace it with a new or reconditioned unit of the same or similar design. The repair or replacement unit
is warranted for (a) ninety days (b) the remainder of the original two-year warranty period, whichever is longer.
Limitations:
Implied warranties, including those of tness for a particular purpose and merchant ability (an unwritten warranty that the
product is t for ordinary use) are limited to two years from the date of purchase. Security Brands, Inc. will not pay for loss
of time, inconvenience, loss of use of your SBI, AAS, or SAC product, service calls, or property damage caused by your SBI,
AAS, or SAC product or its failure to operate, or any other incidental or consequential damages. Some states do not allow
limitations on how long an implied warranty lasts or the exclusion or limitation of incidental or consequential damages, so
the above exclusions or limitations may not apply to you.
What We Ask You To Do:
To receive warranty service for your SBI, AAS, or SAC product, you must provide proof of the date of purchase. Contact the
original dealer or installer of the product, and return your SBI, AAS, or SAC product along with the receipt to them. If you
have problems locating the dealer or installer, contact Security Brands, Inc. at (972) 474-6390, and we will direct you to an
SBI, AAS, or SAC authorized dealer or distributor. If you ship your SBI, AAS, or SAC product, you must prepay all shipping
charges. We suggest that you retain your original packing material in the event you need to ship your SBI, AAS, or SAC
product. Upon return, include your name, address, phone number, proof of date of purchase, and a brief description of
the problem. This information needs to be included to receive a Return Merchandise Authorization (RMA) number.
What This Warranty Does Not Cover:
The warranty does not cover defects resulting from accidents, damage while in transit, alterations, unauthorized repair,
failure to follow installation and operating instructions, misuse, re, ood, or acts of God. Nor do we warrant your SBI,
AAS, or SAC product to be compatible with any particular external device or peripheral. If your warranty has expired on
your SBI, AAS, or SAC product, or if your product is NOT covered, contact your dealer or installer for advice on whether we
will repair your SBI, AAS, or SAC product and for other repair information, including estimated repair costs and additional
charges that may be incurred. We, at our option, may replace, rather than repair your SBI, AAS, or SAC product with a new
or similar design if the damage to the unit is severe or extensive. This is the only warranty we oer on this product, and it
sets forth all our responsibilities regarding your SBI, AAS, or SAC product. There are no other express warranties.
State Law Rights:
This warranty gives you specic legal rights, and you may also have other rights which vary from state to state.
Serial Number ______________________________

Page 2 | Security Brands, Inc.
RTE P Touchless Request-to-Exit Station | Installation and Use Manual
Wiring Diagram
Specications
Power Input 12–24 VDC ±10%
Range 1.25 in. to 4.5 in. (±25%)
Output Loading 1 A @ 30 VDC (Max.)
Output State Trigger state (0.5–20 seconds) or toggle mode output
Lifetime Infrared Sensor: 100,000 hours Relay: 1,000,000 uses
Indicator Standby: RED (default) / Proximity: GREEN (default) Color of LED is adjustable
Case Stainless Steel
Current Consumption Maximum current: 45 mA 24 VDC
Dimensions 5.25 in. (H) x 4.0 in. (W) x 3.0 in. (D)
Weight 2.4 lbs (complete enclosure)
Features
• Adjustable sensor range up to 4.5 inches.
• Stainless-steel faceplate. Powder-coated enclosure.
• Weather-resistant for outdoor use.
• 1-A relay with adjustable trigger duration (0.5–20 seconds or toggle).
• LED illuminated sensor area for easy identication.
• Congurable LED colors (toggle red to green or green to red) to show sensor is activated.

Security Brands, Inc. | Page 3
RTE P Touchless Request-to-Exit Station | Installation and Use Manual
Common Installation Examples

Page 4 | Security Brands, Inc.
RTE P Touchless Request-to-Exit Station | Installation and Use Manual
Care and Cleaning for the Sensor
The sensor requires special care to ensure reliability and a long operating life.
1. Use a soft, clean cloth for cleaning, and use the mildest cleaner available.
2. When cleaning, spray the cleaning solution onto the cleaning cloth instead of the unit itself.
3. Be sure to wipe o any excess liquid from the sensor. Wet spots or wet areas may aect the sensor’s performance.
WARNING: Use caution when mounting! Incorrect mounting, which leads to exposure to rain or moisture
inside the enclosure could cause a dangerous electric shock, damage to the unit, and/or could void the warranty!
Installation
1. Run four wires through pedestal (or similar mounting hardware).
2. Connect four wires to request-to-exit sensor according to wiring diagram on previous page.
3. Reattach stainless-steel faceplate to enclosure, taking care not to crimp any wires.
4. Remove clear protective lm from front face of sensor before use.
WARNING: Do not connect any device that will exceed 1 A @ 30 VDC! This can damage the unit!
Changing the LED Color Jumper Placement
Adjusting the Sensor Range and Trigger Time
1. The sensor range can be adjusted
from 1.25 in. - 4.5 in.
2. The trigger time can be adjusted
from 0.5 to 20 seconds or toggle.
IMPORTANT: Do not force the
adjustment trimpots to turn.
Only minimal force is required.
Standby: Red
Trigger: Green
(default)
Standby: Green
Trigger: Red

Security Brands, Inc. | Page 5
RTE P Touchless Request-to-Exit Station | Installation and Use Manual
NEED HELP
Customer Service
(972) 474-6390
Technical Support
(972) 474-6390
Both services are available free of charge Monday–Friday, 8 am to 5 pm Central Time.
When you call, please have both your model and serial numbers handy for quicker service.

© 2021 Security Brands, Inc. All rights reserved. M-58RTEP-01-EN Rev. A (5/2021)
(972) 474-6390
securitybrandsinc.com
RTE P|Installation and Use Manual
Touchless Request-to-Exit Station
Model 58-rte-p
This manual suits for next models
1
Table of contents
Other Security Brands Remote Control manuals