IMPORTANT
VERY IMPORTANT
ANY FAILURE TO CARRY
OUT THE REQUIRED MAINTENANCE AND SERVICING, AND ANY
FAILURE TO FILL OUT THE MAINTENANCE SCHEDULE, WILL VERY
LIKELY VOID YOUR WARRANTY.
As with any product that has moving parts or is subject to wear and tear, it is
that you maintain your air conditioner and have it regularly
serviced. Accordingly, it is a condition of warranty cover for your air conditioner
that you comply with all of the maintenance and service requirements set out
in this Manual. Compliance with these requirements will prolong the life of your
air conditioner. Further, it is also a condition of warranty cover that the
Maintenance Schedule in the Manual is filled out (by signing and dating it in
the places indicated) when the item is completed.
(For complete warranty terms, refer to the separate Warranty Booklet sold with
the product. Alternatively, visit to download the terms.
Warranty terms are subject to property access and industry safety standards.)
www.braemar.net.au
iWIRED CONTROLLER - XK76
2
i

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
1
MAIN COMPONENTS.........................................................................................2
INTRODUCTION & SAFETY ..............................................................................3
OPERATION
WIRED CONTROLLER .................................................................................4
CONTROLLER LAYOUT...............................................................................4
LCD ICONS ................................................................................................5-6
BUTTON FUNCTIONS...............................................................................6-7
ON/OFF .........................................................................................................7
MODE, TEMPERATURE, FAN SETTING .....................................................8
RIGHT, LEFT SWING FUNCTION ................................................................9
UP, DOWN SWING FUNCTION ..................................................................10
TIMER SETTING ....................................................................................11-12
AIR EXCHANGE SETTING....................................................................12-13
SLEEP SETTING ...................................................................................13-15
HEALTH SETTING.................................................................................15-16
I-DEMAND SETTING .............................................................................16-17
VACATION SETTING .............................................................................17-18
TURBO FUNCTION SETTING...............................................................18-19
SAVE FUNCTION SETTING ..................................................................19-21
E-HEATER SETTING .............................................................................21-22
BLOW FUNCTION SETTING.................................................................22-23
FILTER SETTING...................................................................................23-25
QUIET FUNCTION SETTING......................................................................26
ULTRA-DRY SETTING................................................................................27
LOCK FUNCTION .......................................................................................27
MEMORY FUNCTION .................................................................................27
CENTIGRADE - FAHRENHEIT ...................................................................27
AMBIENT TEMPERATURE ENQUIRY .......................................................27
INDOOR FAN SHUTDOWN MODE ............................................................28
ERROR DISPLAY...................................................................................29-31
MAINTENANCE & SERVICE............................................................................32
MAINTENANCE SCHEDULE ...........................................................................33
OPERATION TIPS.............................................................................................34
TROUBLESHOOTING ......................................................................................35
SEELEY INTERNATIONAL – OWNER’S MANUAL 1
CONTENTS
INTRODUCTION & SAFETY ..............................................................................2
OPERATION
WIRED CONTROLLER .................................................................................3
CONTROLLER LAYOUT...............................................................................3
LCD ICONS ...................................................................................................4
BUTTON FUNCTIONS..................................................................................
ON/OFF .........................................................................................................6
6
MODE............................................................................................................
TEMPERATURE SETTING...........................................................................
FAN SPEED SETTING..................................................................................
SWING SETTING..........................................................................................
FUNCTION SETTING....................................................................................
FRESH AIR FUNCTION..............................................................................
SLEEP FUNCTION..........................................................................................
HEALTH FUNCTION ..................................................................................
I-DEMAND FUNCTION ...............................................................................
HOLIDAY FUNCTION..................................................................................
MEMORY FUNCTION.................................................................................
SAVE FUNCTION........................................................................................
AUXILIARY HEATING.................................................................................
DRY FUNCTION..........................................................................................
QUIET FUNCTION.......................................................................................
FILTER CLEAN REMINDER.......................................................................
FAHRENHEIT SETTING.............................................................................
LOW TEMPERATURE DRYING.................................................................
MAINTENANCE & SERVICE...........................................................................
MAINTENANCE SCHEDULE ..........................................................................
OPERATION TIPS............................................................................................
TROUBLESHOOTING .....................................................................................
CONTENTS
7
8
9
7
10
11
12
12
13
15
14
14
16
17
18
20
20
WIFI FUNCTION..........................................................................................
SETBACK FUNCTION................................................................................
LANGUAGE FUNCTION.............................................................................
21
21
22
UNIT STATUS VIEW....................................................................................
CURRENT ERROR VIEW ...........................................................................
TIMER FUNCTION ......................................................................................
ONE TIME CLOCK TIMER..........................................................................
DAILY TIMER...............................................................................................
WEEKLY TIMER.........................................................................................
TWO WEEK TIMER.....................................................................................
TIME FORMAT SETTING...........................................................................
CLOCK SETTING........................................................................................
LOCK SETTING..........................................................................................
23
23
25
24
25
26
27
COUNT DOWN TIMER................................................................................27
28
29
30
CURRENT ERROR VIEW........................................................................... 32
COMMON ERROR CODES.........................................................................33
34
ERROR DISPLAY
35
36
37
5
MAIN STRUCTURE.....................................................................................31

iWIRED CONTROLLER - KDHV Series Inverter Ducted
2
INTRODUCTION & SAFETY
when the Braemar Air Conditioning Unit
is used. Note: the manufacturer
recommends that low level return air grilles
are installed.
IMPORTANT!
THE AUSTRALIAN GREENHOUSE
OFFICE HAS ISSUED VARIOUS
REGULATIONS ON THE USE AND
DISPOSAL OF REFRIGERANTS IN
THE UNIT. FAILURE TO FOLLOW
THESE REGULATIONS MAY HARM
THE ENVIRONMENT AND COULD
LEAD TO THE IMPOSITION OF
SUBSTANTIAL FINES.
WHERE SPECIFIED, ONLY
QUALIFIED AND LICENSED
TECHNICIANS SHOULD PERFORM
WORK ON THIS UNIT, FAILING
WHICH THE WARRANTY ON THE
UNIT WILL BE VOID.
WARNING! This appliance is not
intended for use by persons (including
children) with reduced physical,
sensory or mental capabilities, or lack
of experience and knowledge, unless
they have been given supervision or
instruction concerning use of the
appliance by a person responsible for
their safety.
Children should be supervised to
ensure that they do not play with the
appliance.
If the supply cord is damaged, it must
be replaced by the manufacturer, its
service agent or similarly qualied
persons in order to avoid a hazard.
Congratulations on purchasing a new
Braemar Air Conditioner!
Please keep this Manual and the
Warranty Booklet in a safe place,
along with the original purchase
documents, plus all relevant
certicates of compliance relating to
the installation work performed. Please
register the Warranty straight away, by
following the steps set out in the
Warranty Booklet.
The installer must read the Installation
Manual before installing the Braemar
Air Conditioning Unit.
The home owner/user should read the
Owner’s Manual before operating the
Unit.
To ensure the warranty on the Unit is
continued and valid, the Unit must be
checked and serviced by the home
owner/user as per the requirements in
the Maintenance & Service section
and the Maintenance Schedule. This
will also prolong the life of your air
conditioner.
The home owner/user should regularly
check the Air Inlet side of the Outdoor
unit to ensure grass, leaf and other
matter are not drawn into or onto the
Inlet side of the Outdoor unit. Restriction
to the air ow across the coil will reduce
the system’s capacity, and result in high
operation pressures and excessive
operating costs.
A return air lter MUST be installed by
the installer at the return air grille. The
air lter should be inspected and
cleaned at least every two weeks

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
3
OPERATION
CONTROLLER LAYOUT
Appearance and LCD Icons
Wired Controller appearance
Your Braemar Air Conditioner
has been designed and built with reliable,
quality components. To ensure many years
of trouble free, dependable service
please read the following pages very
carefully, and please ensure that you
follow all of the instructions.
WIRED CONTROLLER
Please follow the below cautionary
notes when using the wired controller:-
1. Do not install the wired controller in
a damp place or under direct sunlight.
2. Do not abuse, toss, or frequently
assemble/disassemble the wired
controller.
3. Do not operate the wired controller
with wet hands and never let any liquid
ow into it.
4. Do not install or remove the wired
controller by yourself. If necessary,
please contact a service agent.
5. This wired controller is applicable to
various kinds of air conditioners -
some specic functions unavailable to
the duct type air conditioners will be
covered in this manual.
6. Before operating the air conditioner,
please read this manual carefully and
keep it in a safe place for future
reference.
08:30
ON/OFFFAN
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
08:30
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO

iWIRED CONTROLLER - KDHV Series Inverter Ducted
4
OPERATION cont.
Display Denition Display Denition
Fresh air Function Fan Speed
Health Function Cooling Mode
Time On Status Filter Reminder
Sleep Function Lock Setting
Holiday Function Clock
Quiet Function Dry Mode
I-Demand Function Fan Mode
Memory Function Heating Mode
DRED Function Auto Mode
Save Function WiFi Function
Dry Function Independent Swing
Shielding Function Setback Function
Gate Card Auxiliary Heating
Left and right swing
function
Up and down swing
function
Menu
LCD ICONS
MENU
08:30

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
5
OPERATION cont.
BUTTON FUNCTION
No Button Name Button Function
1 Fan Set low, medium,
high, turbo, auto
2∧(1) Set Temperature
(2) Set parameter
(3) Move option
cursor
6∨
3On/O/Back
(1) Turn on or turn
o unit
(2) Return to last
page
4 Swing
Set up & down
swing and set left
and right swing
5<(1) Set related
function on or o
(2) Move option
cursor
(3) Set parameter
8>
7 MENU/OK
(1) Enter menu
page
(2) Conrm setting
9 MODE
Set auto, cooling,
dry, fan and heating
modes for indoor
unit.
10 Remote
Receiver
For use with the
wireless wall
controller (optional)
ON/OFFFAN
SWING
MENU/OK
MODE
1
4 6 7 9
5
2 8 10 3

iWIRED CONTROLLER - KDHV Series Inverter Ducted
6
OPERATION cont.
ON / OFF
Press the On/O button to turn the unit
on or o.
MODE SETTING
Under the ON state of the unit, press
the Mode button to switch the
operation modes as the sequence
shown below.
08:30
ON/OFFFAN
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
08:30
ON/OFFFAN
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
7
OPERATION cont.
FAN SPEED SETTING
Press the Fan button to vary the speeds as
shown in the sequence below.
TEMPERATURE SETTING
Press ∧or ∨button to increase or
decrease setting temperature when the unit
is on. Pressing either of them continuously,
will increase or decrease by 1°C every 0.3s.
In Cooling, Dry, Fan and Heating mode,
temperature setting range is 16°C - 30°C.
In Auto mode, the setting temperature is not
adjustable.
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
25
COOL
AUTO
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
Low Mid-low Mid-highMiddle
High
TurboAuto
Press ∧or ∨
button to increase or
decrease the
temperature when
the unit is on.
Pressing ∧or
∨continuously,
temperature will
be increased or
decreased by 1°C
every 0.5s.

iWIRED CONTROLLER - KDHV Series Inverter Ducted
8
OPERATION cont.
UP / DOWN SWING SETTING
Under the ON state of the unit, press the
SWING button to select the “Up and Down
Swing” function option.
When the SWING function is activated,
press the Menu/OK button to select the
“Up and Down Swing” function.
LEFT / RIGHT SWING SETTING
Under the ON state of the unit, press the
SWING button to select the “Left and Right
Swing” function option.
When the SWING function is activated,
press the Function button to select the “Left
and Right Swing” function.
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
Unit On, no
Up and Down swing.
Unit On, no
right-left swing
Press “SWING”
button to set
up-down swing
function.
Press the Menu/OK
button to conrm.
Press “SWING”
button twice to set
up-down swing
function.
Press the Menu/OK
button to conrm.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
9
OPERATION cont.
FUNCTION SETTING cont.
FUNCTION SETTING
Press MENU/OK button on main page to
enter main menu page. Press ∧or ∨or
<or >button to select the function setting
symbol.
Then press MENU/OK button to enter user
function setting page. Press ∧or ∨button
to select specic function item.
Press <or > button to turn on or turn o this
function. If the function item can’t be set, it
will be shaded with gray.
08:30
ON/OFFFA N
SWING
MENU/OK
MODE
SET
C
10/06/2014 MON
MENU
24
COOL
AUTO
MENU
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
FUNCTION CLOCK
LOCK
TIMER
SEARCH
MENU
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
FUNCTION CLOCK
LOCK
TIMER
SEARCH
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFAN
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
Press MENU/OK
button on main page
to enter main menu
page.
Press MENU/OK
button to enter user
function setting
page.
Press ∧or ∨or <
or >button to select
the function setting
symbol.
Press ∧or ∨button
to select specic
function item.
Press <or >button
to select specic
function item.

iWIRED CONTROLLER - KDHV Series Inverter Ducted
10
OPERATION cont.
FRESH AIR FUNCTION
This is used to adjust the fresh air
volume indoors to improve air quality.
Note:
1. Air function is applicable only to units
with air function and installed with fresh air
electric valve (fresh air valve in short).
1―The unit continuously runs for 60min,
and fresh air valve runs for 6 min.
2―The unit continuously runs for 60min,
and fresh air valve runs for 12 min.
3―The unit continuously runs for 60min,
and fresh air valve runs for 18 min.
4―The unit continuously runs for 60min,
and fresh air valve runs for 24 min.
5―The unit continuously runs for 60min,
and fresh air valve runs for 30 min.
6―The unit continuously runs for 60min,
and fresh air valve runs for 36 min.
7―The unit continuously runs for 60min,
and fresh air valve runs for 42 min.
8―The unit continuously runs for 60min,
and fresh air valve runs for 48 min.
9―The unit continuously runs for 60min,
and fresh air valve runs for 54 min.
10―The unit continuously runs for 60min,
and fresh air valve always runs.
FRESH AIR FUNCTION cont.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFAN
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
Press ∧or ∨button
to select
fresh air function.
Press <or >button
to turn on or turn o
air function.
Press MENU/OK
button to adjust the
mode of fresh air.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
11
OPERATION cont.
SLEEP FUNCTION cont.
SLEEP FUNCTION
The indoor unit enters a sleep state and
operates according to a preset sleep
temperature curve to create a comfortable
sleeping environment and improve sleep
quality.
When in COOL, HEAT or DRY modes,
press the SLEEP button to start up the
sleep function.
The icon SLEEP icon is displayed on the
remote controller. Default setting is SLEEP
mode ‘OFF’.
In COOL and DRY modes, after
running for one hour, the main unit
SET temperature will increase by 1°C,
then after 2 hours will increase by 2°C,
then will continue to run at this
temperature.
NOTE:
- In fan or auto mode, sleep function is not
available.
- Sleep function will be canceled when
turning o the unit or switching modes.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFAN
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
When in function
page press ∧or ∨
button to select
sleep function.
Sleep function and
press <or >button
to turn on or turn o
sleep function.
Press the MENU/OK
button to confirm.

iWIRED CONTROLLER - KDHV Series Inverter Ducted
12
OPERATION cont.
HEALTH FUNCTION
Generate negative ions to ensure the
health. During operation of indoor fan, set
health function by wired wall controller.
Note: Function is optional.
I-DEMAND FUNCTION
When the unit is rst turned on in COOL
or HEAT modes, set I-Demand to quickly
reach the SET temperature. Icon will be
shown. I-Demand mode is cancelled if
MODE or FAN speed is changed.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFAN
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
Press ∧or ∨button
to select health
function.
Press ∧or ∨button
to select I-DEMAND
function.
Press <or >button
to turn on or turn o
health function.
Press <or >button
to turn on or turn o
this function.
Press the MENU/OK
button to conrm.
Press the MENU/OK
button to conrm.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
13
OPERATION cont.
HOLIDAY FUNCTION cont.
HOLIDAY FUNCTION
This is used to maintain indoor
temperature so that unit can quickly heat
upon startup. Holiday function can be
enabled only in Heat mode.
If wired controller is connected to
temperature-humidity dual-control duct type
indoor unit, Holiday function cannot be
used.
NOTE:
- This function is only available in heating
mode.
- When this function has been set, set
temperature is displayed in 8ºC. In this
case, temperature setting and fan speed
setting are shielded.
- This function will be canceled when
switching modes.
- This function and sleep function cannot
be on simultaneously. If holiday function
is set rst and then sleep function is set,
holiday function will be canceled while
sleep function will be valid, and vice versa.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
Press ∧or ∨button
to select holiday
function.
Press <or >button
to turn on or turn o
this function.
Press the MENU/OK
button to conrm.

iWIRED CONTROLLER - KDHV Series Inverter Ducted
14
OPERATION cont.
MEMORY FUNCTION
After power recovery, the unit will be turned
on automatically according to memory
content. Mode, up & down swing, light, set
temperature, set fan speed, general timer.
SAVE FUNCTION
Air conditioner operates within a smaller
temperature range to conserve energy.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
FRESH AIR
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
SAVE FUNCTION
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
SAVE FUNCTION
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
SLEEP
HEALTH
IDEMAND
HOLIDAY
MEMORY
SAVE FUNCTION
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
Press ∧or ∨button
to select memory
function.
Press <or >button
to turn on or turn o
memory function.
Press ∧or ∨
button to select save
function.
Press the MENU/OK
button to conrm.
Press <or >button
to turn on or turn o
save function.
Press the MENU/OK
button to conrm.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
15
OPERATION cont.
AUXILIARY HEATING
In the heating mode, auxiliary heat
function is started up to improve the heating
eciency. Note: Function may not be
applicable to unit.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
HEALTH
IDEMAND
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
HEALTH
IDEMAND
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
AUXILIARY HEATING
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
HEALTH
IDEMAND
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
ON OFF
AUXILIARY HEATING
Press ∧or ∨
button to select
auxiliary heating
function.
press <or >button
to turn on or turn
o this function.
Press the
MENU/OK button
to conrm.

iWIRED CONTROLLER - KDHV Series Inverter Ducted
16
OPERATION cont.
DRY FUNCTION
The dry function can be used in
COOL or DRY modes, to continue operation
of the indoor fan for an additional
2 minutes after the power is turned o (so
as to remove excess moisture from the
indoor coil).
NOTE:
- This function is only available in cooling
mode and dry mode.
- When this function is on, if the air
conditioner is turned o, the indoor fan will
still operate at low speed for a while after
turning o.
DRY FUNCTION cont.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
DRY
IDEMAND
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
DRY
IDEMAND
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
DRY
IDEMAND
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
ON OFF
Press ∧or ∨
button to select
dry function.
Press <or >button
to turn on or turn o
this function.
Press the MENU/OK
button to conrm.

SEELEY INTERNATIONAL – OWNER’S MANUAL 1
iWIRED CONTROLLER - KDHV Series Inverter Ducted
17
OPERATION cont.
QUIET FUNCTION cont.QUIET FUNCTION
QUIET function can be employed to use
lower fan speeds to attain the SET
temperature when in AUTO, COOL and
HEAT modes. The QUIET icon will be
displayed.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
QUIET
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
DRY
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
QUIET
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
DRY
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
QUIET
HOLIDAY
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
DRY
ON OFF
Press ∧or ∨
button to select quiet
function.
Press <or >button
to turn on or turn o
this function.
Press the MENU/OK
button to conrm.

iWIRED CONTROLLER - KDHV Series Inverter Ducted
18
OPERATION cont.
FILTER CLEAN REMINDER
This function is used to remind you to clean
the lter when the unit’s own operating time
is reach your setting.
Whenever you turn o this function, the
unit’s operating time will be zero.
Level 1 - The range of accumulating
operating time is 5500~10000 hours, with
500 hours in each increase or decrease.
Level 2 - The range of accumulating
operating time is 1400~5000 hours, with
400 hours in each increase or decrease.
Level 3 - The range of accumulating
operating time is 100~1000 hours, with 100
hours in each increase or decrease.
FILTER CLEAN REMINDER cont.
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
QUIET
FILTER CLEAN
MEMORY
SAVE
ON/OFFFAN
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
DRY
ON OFF
ON OFF
ON OFF
ON OFF
ON OFF
FUNCTION
QUIET
FILTER CLEAN
MEMORY
SAVE
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
AUXILIARY HEATING
DRY
ON OFF
FILTER CLEAN
POLLUTION LEVEL
ACCUMULATING TIME
01
500 HOURS
ON/OFFFA N
SWING
MENU/OK
MODE
MENU
After entering user
function page, press
∧or ∨button to
select lter clean
function option.
Press <or >button
to turn on or turn o
this function.
Press MENU button
to enter the setting
page of lter clean
reminder function.
Press ∧or ∨
buttons to select
pollution level.
This manual suits for next models
1
Table of contents
Popular Temperature Controllers manuals by other brands

Oregon Scientific
Oregon Scientific THGR328N user manual

Ranco
Ranco ETC installation instructions

dirna Bergstrom
dirna Bergstrom bycool green line LITE Troubleshooting

KMC Controls
KMC Controls STW-6014 installation guide

Linear Technology
Linear Technology DC2261A manual

RKC INSTRUMENT
RKC INSTRUMENT SA100 Series instruction manual