HDA 300
Instruction manual
Sensitivity level
on ear simulator with adapter (plate) and
conical ring according to IEC 60318-1:2010*
on 6 ccm coupler according to
IEC 60318-3:2010
Frequency in Hz
Mean value
on B&K 4153
in dB re 1 Pa/V
Standard
deviation in dB
Mean value
on B&K 4152
in dB re 1 Pa/V
Standard
deviation
63 34.9 0.58 24.5 1.08
80 35.6 0.75 27.2 0.90
100 36.1 0.58 29.1 0.68
125 36.1 0.88 30.5 0.52
160 37.2 0.40 31.7 0.41
200 38.0 0.31 32.5 0.29
250 38.0 0.67 33.1 0.44
315 38.6 0.77 34.2 0.27
400 38.2 1.03 35.3 0.22
500 37.2 1.05 36.3 0.22
630 35.4 0.75 37.5 0.28
750 33.5 0.61 38.2 0.41
800 32.7 0.53 38.4 0.34
1,000 30.1 0.28 38.8 0.61
1,250 27.5 0.37 37.4 0.62
1,500 25.2 0.26 36.0 0.29
1,600 24.3 0.33 35.3 0.20
2,000 21.1 0.52 33.2 0.58
2,500 20.3 0.54 32.0 0.42
3,000 20.0 0.55 29.7 0.36
3,150 19.8 0.55 29.0 0.29
4,000 16.3 0.46 26.7 0.14
5,000 26.1 0.20 27.0 0.36
6,000 26.4 0.25 28.9 0.54
6,300 26.7 0.36 28.3 0.54
8,000 28.1 1.56 18.4 0.74
10,000 19.4 0.43
12,000 24.1 0.81
12,500 20.2 0.68
14,000 17.5 1.04
16,000 16.1 0.85
* Measured with additional adapter ring for a quicker and more accurate positioning on coupler
plate of the ear simulator. This is optionally available from Sennheiser.
Reference equivalent threshold sound pressure level (re 20 µPa)
on ear simulator with adapter (plate) and conical ring according to IEC 60318-1:2010
Frequency in Hz
Mean value
on B&K 4153
in dB re 1 Pa/V
Standard
deviation in dB
Median value ***
on B&K 4153 in dB
Interquartile
range in dB
125 26.2 3.9 27.0 5.5
250 20.1 3.1 20.0 4.0
500 8.6 4.0 8.0 3.5
750* 5.1 4.5
1,000 2.7 4.6 2.0 4.5
1,500 3.2 7.1 3.0 6.5
2,000 0.5 4.5 0.0 7.0
3,000 -1.6 6.0 -3.0 7.5
4,000 0.1 5.4 -0.5 5.5
5,000 11.3 4.4 10.5 6.0
6,000 20.9 7.2 21.0 7.5
8,000 23.1 6.1 23.0 6.0
9,000 27.1 5.4 27.5 7.0
10,000 18.5 5.7 18.0 6.0
11,200 22.9 5.6 22.0 8.5
12,500 27.0 5.5 27.0 10.0
14,000 32.8 6.9 33.5 7.5
16,000 47.7 14.4 45.5 12.5
Reference equivalent threshold sound pressure level (re 20 µPa)
on 6 ccm coupler according to IEC 60318-3:2010
Frequency in Hz
Mean value
on B&K 4152
in dB re 1 Pa/V
Standard
deviation in dB
Median value ***
on B&K 4152 in dB
Interquartile
range in dB
125 22.3 3.9 23.0 5.4
250 14.7 3.1 14.5 4.0
500 7.4 4.0 6.5 3.5
750* 9.5 9.0
1,000 11.0 4.6 10.5 4.0
1,500 14.8 7.1 14.5 7.0
2,000 12.3 4.5 12.0 7.0
3,000 8.0 6.0 6.5 7.5
4,000 10.0 5.4 9.5 5.5
5,000 12.3 4.4 11.5 6.0
6,000 23.0 7.2 23.0 7.5
8,000 15.9 6.1 16.0 6.0
* interpolated values
*** rounded to nearest 0.5 dB
Audiometric headphones
Sennheiser electronic GmbH & Co. KG
Am Labor 1, 30900 Wedemark, Germany
www.sennheiser.com
Printed in Germany, Publ. 01/15, 545391/A02
Reference of measurements
Physikalisch-Technische Bundesanstalt (PTB), Braunschweig, Germany
Test Report Audiometric Headphones HDA 300
Reference no: 1.61 – 4064893/13
Measurement conditions
Temperature: 22 °C
Relative humidity: 50 %
HDA 300
HDA300_UmschlagAufklapp.indd 1-5 21.01.2015 13:00:01