SEP 120/360/900 ST
www.sepura-technologies.com
installation manual
1
Before Starting Assembly, please
check contents are as follows:
•1White Felt Bag Filter with black tube
•1Silexa Filter
•1Test Bottle
•1Cleaner Tower (120,360 or 900)
•1Drilled Lid
•- Metal Retaining Springs
SEP120 = 1 x 170mm
SEP360 = 1 x 250mm
SEP900 = 2 x 400mm
Service interval kit comprising;
• moulded plastic mount + screw
• printed card
• self-adhesive Timestrip.
Fitting kit containing;
•1Straight adaptor 15mm x 1/2” BSP
•1Blanking Plug - large
•1Elbow 15mm
•1Assembled Porting Block
•3Porting Block Small Blanking Plugs
•4Screw 4.8x45mm and washers
•2Grab Taps
•1Blue nylon adaptor
•1Black Tube:
SEP120 = 73mm
SEP360 = 100mm
SEP900 = 180mm
Insert the boss on the reverse of
the mount (c) into the pre-drilled
hole in the separator lid.
Peel backing from timestrip (a)
and attach to the plastic card (b)
within the dotted lines.
Flex the card, passing the ends
through the slots on the top
surface of the mount.
To activate, press firmly on
the timestrip label at the
point indicated.
After a few minutes a red line
will appear, to indicate ‘time in
service’ up to 12 months
A replacement card and
timestrip will be supplied with
each service kit.
i
ii
iii
General Installation notes
•Please ensure a steady
fall in the pipe run from
the outlet point to the
foul drain.
•Never discharge
condensate to a storm
drain or to surface water;
always connect to a foul
drain or sewer.
•Remember that it’s the
user’s responsibility to
check with the local
authority as to the
permissible discharges
in their area.
Testing Quality
Replace filters before outlet
cloudiness exceeds the ppm
limit for your region.
Test outlet quality weekly
using kit provided.
Further information is available on our website below.
(c)
(b)
(a)
Service Indicator -
assembly and attachment