manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Sepura
  6. •
  7. Water Filtration System
  8. •
  9. Sepura SEP 120 D User manual

Sepura SEP 120 D User manual

SEP 120/360/900/1250 D
www.sepura-technologies.com
installation manual
1
Before Starting Assembly, please
check contents are as follows:
•1White Felt Bag Filter with black tube
•1Carbon Filter
•1Test Bottle
•1Cleaner Tower (120, 360, 900 or 1250)
•1Drilled Lid
Service interval kit comprising;
• moulded plastic mount + screw
• printed card
• self-adhesive Timestrip.
Fitting kit containing;
•1Straight adaptor 15mm x 1/2” BSP
•1Blanking Plug - large
•1Elbow 15mm
•1Assembled Porting Block
•3Porting Block Small Blanking Plugs
•4Screw 4.8x45mm and washers
•2Grab Taps
•1Blue nylon adaptor
•1Black Tube:
SEP120 = 73mm
SEP360 = 100mm
SEP900 = 180mm
SEP1250 = 200mm
Insert the boss on the reverse of
the mount (c) into the pre-drilled
hole in the separator lid.
Peel backing from timestrip (a)
and attach to the plastic card (b)
within the dotted lines.
Flex the card, passing the ends
through the slots on the top
surface of the mount.
To activate, press firmly on
the timestrip label at the
point indicated.
After a few minutes a red line
will appear, to indicate ‘time in
service’ up to 12 months
A replacement card and
timestrip will be supplied with
each service kit.
i
ii
iii
General Installation notes
•Please ensure a steady
fall in the pipe run from
the outlet point to the
foul drain.
•Never discharge
condensate to a storm
drain or to surface water;
always connect to a foul
drain or sewer.
•Remember that it’s the
user’s responsibility to
check with the local
authority as to the
permissible discharges
in their area.
Testing Quality
Replace filters before outlet
cloudiness exceeds the ppm
limit for your region.
Test outlet quality weekly
using kit provided.
Further information is available on our website below.
(c)
(b)
(a)
Service Indicator -
assembly and attachment
superior technologies
SEP 120/360/900/1250 D
www.sepura-technologies.com
t: +44 (0)1543 379212
e: [email protected]
23 4
Fit the inlet block to your chosen side using the screws
provided. (Extra blocks can be purchased if required.)
Completed
SEP 120 D
SEP 360 D
SEP 900 D
SEP 1250 D
Units
Insert the large blanking plug into the
remaining unused port block located on the
opposite side of the unit.
Insert the SILEXA™Carbon filter bag (white netting
with tied top) pushing it gently but firmly down to
the base of the unit.
Insert the second filter bag (needle-felt bag with
the pipe inlet hole on the top) and rest it on top of
the SILEXA™Carbon filter bag.
Screw the inlet connector (Reducing Bush)
into place tightly.
Connect the filter tube to
the inlet block using the fittings supplied.
Assemble and attach the service life indicator to the lid
of the unit using the pre-drilled hole.
See overleaf for more detail.
For information on the
correct positioning and
installation of your
Sepura Separator
Unit please see the
accompanying leaflet.
For SEP 120 D and SEP 360 D
consider using our Wall Mounted Brakcet.
See our website for details.
567
9
Attach the twist off Grab Tap to the test point.
Attach your outlet hose to the nipple above.
Fill unit with water and check for leaks.
8

This manual suits for next models

3

Other Sepura Water Filtration System manuals

Sepura SEP 60 ST User manual

Sepura

Sepura SEP 60 ST User manual

Sepura Sep 1800 ST User manual

Sepura

Sepura Sep 1800 ST User manual

Sepura SEP 120 ST User manual

Sepura

Sepura SEP 120 ST User manual

Sepura SEP 3500 ST User manual

Sepura

Sepura SEP 3500 ST User manual

Sepura SEP 360 D User manual

Sepura

Sepura SEP 360 D User manual

Popular Water Filtration System manuals by other brands

Oase BioTec ScreenMatic 2 40000 operating instructions

Oase

Oase BioTec ScreenMatic 2 40000 operating instructions

Teka WNA operating instructions

Teka

Teka WNA operating instructions

Watts IS-OR-NH installation instructions

Watts

Watts IS-OR-NH installation instructions

AAF SAAF PORTA-Scrubber PS-200 Installation, operation and maintenance instructions

AAF

AAF SAAF PORTA-Scrubber PS-200 Installation, operation and maintenance instructions

kent marine MAXXIMA MAX24 instructions

kent marine

kent marine MAXXIMA MAX24 instructions

Watts PWSYS-UF-KC3 Installation, operation and maintenance manual

Watts

Watts PWSYS-UF-KC3 Installation, operation and maintenance manual

BWT GROHE Blue 40 691 manual

BWT

BWT GROHE Blue 40 691 manual

MSA OptimAir 3000 operating manual

MSA

MSA OptimAir 3000 operating manual

Fahl LARYVOX TAPE Instructions for use

Fahl

Fahl LARYVOX TAPE Instructions for use

Lancaster ECOSENSE 7-UFAS-011 Installation, operating and service manual

Lancaster

Lancaster ECOSENSE 7-UFAS-011 Installation, operating and service manual

AQUARIUS AD300 installation guide

AQUARIUS

AQUARIUS AD300 installation guide

Cleveland SteamerGard WT-300 Installation, operation and maintanance manual

Cleveland

Cleveland SteamerGard WT-300 Installation, operation and maintanance manual

SunSun CUV-1 Series Operation manual

SunSun

SunSun CUV-1 Series Operation manual

Pentair FLECK 5800 SXT Installer manual

Pentair

Pentair FLECK 5800 SXT Installer manual

Flurida FDFB10501 installation instructions

Flurida

Flurida FDFB10501 installation instructions

Berkey Wellspring manual

Berkey

Berkey Wellspring manual

Sawyer SP160 Use & maintenance

Sawyer

Sawyer SP160 Use & maintenance

uv guard CWP-Series Installation and operation manual

uv guard

uv guard CWP-Series Installation and operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.