Sentry : Solutions for the Data Center Equipment Cabinet
Key Features
Sentry : CDU Technical Specifications
Sentry Switched CDU
CW-8H
High-Density Power Distribution
The Switched CDU’s combine remote configuration and management with power
distribution and power and environmental monitoring. Reboot a single or
dual-power server with one command. Receive SNMP-based alerts and email alerts
when power or environmental conditions exceed thresholds. Assign users specific
access rights to designated outlets or groups.
Only the Switched CDU products provide the flexibility needed for all data centers
and remote sites, including power requirements for high-amp, high voltage; UL
60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current
monitoring.
> Remote Power Management:
Power cycle individual power
outlets, or groups of power
outlets, to remotely reboot
servers and network devices,
anywhere in the world. Or,
power-off unused power
receptacles
> High Power Distribution: 120V,
208V, or 230V power; 20 or
30-Amp power input feed
options
> High Density: Single power
input feed; 8 outlets per 1U
enclosure
> IP Access & Security: Web
interface, SSL, SSH, Telnet, SNMP,
FTP, SNTP, Syslog, LDAP, LDAPS,
TACACS and RS-232 access
> Add an Expansion Module:
Daisy chain the Switched CDU
Expansion Module (CW/CX) for
power management of separate
power circuits from a single IP
address
> Environmental Monitoring:
Each Switched CDU supports two
temperature & humidity probes
and reports conditions thru the
Web interface
> SNMP Traps: Provide automated
alerts for power and
environmental conditions
> Input Current Monitor:
Precisely measure the aggregate
current draw (in amps) on each
power circuit. On-site
verification of the input current
with the LED digital display.
Remote verification via browser
or serial screen.
> Power-up Sequencing: Prevent
an in-rush power overload
Branch Circuit Protection
The Sentry CDU Family meets the new UL 60950-1
requirement for branch circuit protection.
Attention! The Sentry CDU products meet the above criteria by
providing overcurrent protection with UL-listed Bussman SC fuses for
each branch circuit. The CW-8H contains fuses within the enclosure.
Input Current Monitoring
The CDU’s exclusive True RMS current monitoring is critical
to preventing overloads in high-density computing
environments. LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit.
Temperature and Humidity
The Switched CDU supports two external probes. Each of
these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions
exceed defined thresholds.
Additional Benefits:
CW-8H1-C20
CW-8H2-C20
CW-8H1-L530
CW-8H2-L630
100-120V
50/60Hz
100-120V
50/60Hz
208-240V
50/60Hz
208-240V
50/60Hz 30A
20A
30A
20A IEC 60320/C20
Power Inlet
NEMA L5-30P
Cordset
IEC 60320/C20
Power Inlet
NEMA L6-30P
Cordset
(8) NEMA 5-20R
(8) IEC 60320/C13
(8) NEMA 5-20R
(8) IEC 60320/C13
17.0” x 1.75” x 7.0”
17.0” x 1.75” x 7.0”
17.0” x 1.75” x 7.0”
17.0” x 1.75” x 7.0”
Additional Features and Specifications
Branch Circuit Protection
> Compliant to UL 60950-1
Agency Approvals
> US & Canada (cTUVus mark) to UL 60950-1:2003 and
CAN/CSA 22.2 No. 60950-1-03
> European Union (TUVGS mark) to EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC - EN 55022 Class A, EN 55024
Communications and Security
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3
> LDAPS
> TACACS+
> RS-232 (Serial)
Accessories
> Optional Temperature & Humidity Probe
EMTH-1-1 Temperature & Humidity Probe, 10’
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’
> PTCORD-2 IEC 60320/C19 - Schuko 10’
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)
16/20A Blue (UK Commando) 10’
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
**Enterprise View sold separtely
Expansion Module
Model Numbers
> CX-8H1-C20
> CX-8H1-L530
> CX-8H2-C20
> CX-8H2-L630
> CX-8HE-C20
CW-8HE-C20* 230V
50/60Hz 16A IEC 60320/C20
Power Inlet (8) IEC 60320/C13 17.0” x 1.75” x 7.0”
*European Model
© Server Technology, Inc. 7/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc. Patent # 7,043,543. Patent Pending. Printed in US.
Model Available Input
Voltages Outlets
Available Input
Cord
Amperage Dimensions*
(L x W x D)
Sentry : Solutions for the Data Center Equipment Cabinet
Key Features
Sentry : CDU Technical Specifications
Sentry Switched CDU
CW-8H
High-Density Power Distribution
The Switched CDU’s combine remote configuration and management with power
distribution and power and environmental monitoring. Reboot a single or
dual-power server with one command. Receive SNMP-based alerts and email alerts
when power or environmental conditions exceed thresholds. Assign users specific
access rights to designated outlets or groups.
Only the Switched CDU products provide the flexibility needed for all data centers
and remote sites, including power requirements for high-amp, high voltage; UL
60950-1 branch circuit protection; SSL & SSH security; and SNMP-based input current
monitoring.
> Remote Power Management:
Power cycle individual power
outlets, or groups of power
outlets, to remotely reboot
servers and network devices,
anywhere in the world. Or,
power-off unused power
receptacles
> High Power Distribution: 120V,
208V, or 230V power; 20 or
30-Amp power input feed
options
> High Density: Single power
input feed; 8 outlets per 1U
enclosure
> IP Access & Security: Web
interface, SSL, SSH, Telnet, SNMP,
FTP, SNTP, Syslog, LDAP, LDAPS,
TACACS and RS-232 access
> Add an Expansion Module:
Daisy chain the Switched CDU
Expansion Module (CW/CX) for
power management of separate
power circuits from a single IP
address
> Environmental Monitoring:
Each Switched CDU supports two
temperature & humidity probes
and reports conditions thru the
Web interface
> SNMP Traps: Provide automated
alerts for power and
environmental conditions
> Input Current Monitor:
Precisely measure the aggregate
current draw (in amps) on each
power circuit. On-site
verification of the input current
with the LED digital display.
Remote verification via browser
or serial screen.
> Power-up Sequencing: Prevent
an in-rush power overload
Branch Circuit Protection
The Sentry CDU Family meets the new UL 60950-1
requirement for branch circuit protection.
Attention! The Sentry CDU products meet the above criteria by
providing overcurrent protection with UL-listed Bussman SC fuses for
each branch circuit. The CW-8H contains fuses within the enclosure.
Input Current Monitoring
The CDU’s exclusive True RMS current monitoring is critical
to preventing overloads in high-density computing
environments. LED digital displays on the CDU enclosure
report the input current of each phase or branch circuit.
Temperature and Humidity
The Switched CDU supports two external probes. Each of
these probes measure both temperature and humidity.
Receive SNMP-based alert notifications when conditions
exceed defined thresholds.
Additional Benefits:
CW-8H1-C20
CW-8H2-C20
CW-8H1-L530
CW-8H2-L630
100-120V
50/60Hz
100-120V
50/60Hz
208-240V
50/60Hz
208-240V
50/60Hz 30A
20A
30A
20A IEC 60320/C20
Power Inlet
NEMA L5-30P
Cordset
IEC 60320/C20
Power Inlet
NEMA L6-30P
Cordset
(8) NEMA 5-20R
(8) IEC 60320/C13
(8) NEMA 5-20R
(8) IEC 60320/C13
17.0” x 1.75” x 7.0”
17.0” x 1.75” x 7.0”
17.0” x 1.75” x 7.0”
17.0” x 1.75” x 7.0”
Additional Features and Specifications
Branch Circuit Protection
> Compliant to UL 60950-1
Agency Approvals
> US & Canada (cTUVus mark) to UL 60950-1:2003 and
CAN/CSA 22.2 No. 60950-1-03
> European Union (TUVGS mark) to EN 60950-1:2001
> FCC Class A, Part 15
> CE
> EMC - EN 55022 Class A, EN 55024
Communications and Security
> 10/100 BaseT Ethernet
> HTTP/HTTPS
> SSLv3/TLSv1
> SNMPv2
> SSHv2
> Telnet
> LDAPv3
> LDAPS
> TACACS+
> RS-232 (Serial)
Accessories
> Optional Temperature & Humidity Probe
EMTH-1-1 Temperature & Humidity Probe, 10’
Power Cord Options
> PTCORD-1 IEC 60320/C19 - NEMA L6-20P , 10’
> PTCORD-2 IEC 60320/C19 - Schuko 10’
> PTCORD-3 IEC 60320/C19 - IEC 60309 (BS4343, CEE17)
16/20A Blue (UK Commando) 10’
> PTCORD-4 IEC 60320/C19 - BS1363 13A (UK) 10’
> PTCORD-5 IEC 60320/C19 - 5-15P (15A Straight-Blade) 10’
> PTCORD-6 IEC 60320/C19 - 5-20P (20A Straight-Blade) 10’
> PTCORD-7 IEC 60320/C19 - L5-20P (20A Twist-Lock) 10’
> PT-ADP-C19 Cable mount IEC 60320/C19 Connector
**Enterprise View sold separtely
Expansion Module
Model Numbers
> CX-8H1-C20
> CX-8H1-L530
> CX-8H2-C20
> CX-8H2-L630
> CX-8HE-C20
CW-8HE-C20* 230V
50/60Hz 16A IEC 60320/C20
Power Inlet (8) IEC 60320/C13 17.0” x 1.75” x 7.0”
*European Model
© Server Technology, Inc. 7/2007 version. Information in this document is subject to change without notice. Sentry is a trademark of Server Technology, Inc. Patent # 7,043,543. Patent Pending. Printed in US.

This manual suits for next models

5

Other Server Technology Power Distribution Unit manuals

Server Technology Switched Rack PDU User manual

Server Technology

Server Technology Switched Rack PDU User manual

Server Technology switched pro2 User manual

Server Technology

Server Technology switched pro2 User manual

Server Technology CDUCW-16V-MX User manual

Server Technology

Server Technology CDUCW-16V-MX User manual

Server Technology Sentry PT22 Installation guide

Server Technology

Server Technology Sentry PT22 Installation guide

Server Technology CDUCW-24V4 User manual

Server Technology

Server Technology CDUCW-24V4 User manual

Server Technology CW-16V User manual

Server Technology

Server Technology CW-16V User manual

Server Technology Sentry CB-12H Series User manual

Server Technology

Server Technology Sentry CB-12H Series User manual

Server Technology switched pro2 User manual

Server Technology

Server Technology switched pro2 User manual

Server Technology 4805-XLS-16B User manual

Server Technology

Server Technology 4805-XLS-16B User manual

Popular Power Distribution Unit manuals by other brands

DRIESCHER-WEGBERG KSP2132 Operation – and Assembly Instruction

DRIESCHER-WEGBERG

DRIESCHER-WEGBERG KSP2132 Operation – and Assembly Instruction

EuroLite SB-66 user manual

EuroLite

EuroLite SB-66 user manual

Ilsco SSI SpecPRO SRM Series manual

Ilsco

Ilsco SSI SpecPRO SRM Series manual

Geist HT Series instruction manual

Geist

Geist HT Series instruction manual

Vimar ELVOX 46264.002 quick start guide

Vimar

Vimar ELVOX 46264.002 quick start guide

Gems S208 quick start guide

Gems

Gems S208 quick start guide

Vynco VM17 Product information

Vynco

Vynco VM17 Product information

Siemens SIVACON 8PS Configuration manual

Siemens

Siemens SIVACON 8PS Configuration manual

ATEN eco PDU PE Series user manual

ATEN

ATEN eco PDU PE Series user manual

Wöhner CrossBoard 11 225 quick start guide

Wöhner

Wöhner CrossBoard 11 225 quick start guide

Eaton DMM-40 Series Instruction leaflet

Eaton

Eaton DMM-40 Series Instruction leaflet

MTT MS3707 user manual

MTT

MTT MS3707 user manual

Infinite LS Plus 100 installation manual

Infinite

Infinite LS Plus 100 installation manual

Ormazabal velatia ekor.gid General instructions

Ormazabal

Ormazabal velatia ekor.gid General instructions

Tripp Lite PDUMH20HVNET owner's manual

Tripp Lite

Tripp Lite PDUMH20HVNET owner's manual

Bachmann BlueNet BN2000 manual

Bachmann

Bachmann BlueNet BN2000 manual

ETA Systems PD10VRS Specification sheet

ETA Systems

ETA Systems PD10VRS Specification sheet

Furman ASD-120 2.0 owner's manual

Furman

Furman ASD-120 2.0 owner's manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.