Denotes warning or caution. See manual for a description of
the meanings.
DENOTES HIGH VOLTAGE. RISK OF ELECTRICAL SHOCK. LIFE
THREATENING VOLTAGES MAY BE PRESENT. QUALIFIED
PERSONNEL ONLY.
Equipment protected throughout by double insulation (IEC
536 Class II).
Contains additional information pertinent to current subject.
DO NOT EXCEED 347V Line to Neutral or 600V Line to Line. This meter is equipped to monitor loads up
to 347V L-N. Exceeding this voltage will cause damage to the meter to the meter and danger to the user.
Always use a Potential Transformer (PT) for voltages in excess of 347V L-N or 600V L-L. The Setra Power
Meters are 600V Over Voltage Category III device.
To avoid electrical shock or re:
• Review the entire manual before use of the Meter and its accessories.
• Comply with local and national safety codes. Use personal protective equipment to prevent shock and
arc flash injury where hazardous live conductors are exposed.
• Only qualied electrical workers should install this equipment. Such work should be performed only after
reading the full installation and operation manual.
• The equipment must be accessible to authorize personnel only. Equipment must be installed in areas
where access can be restricted.
• If the meter appears damaged or defective or internal fuse brownout, rst disconnect all power to the
meter. Then contact Setra technical support for assistance.
This quick-start guide provides an overview of the safety and installation requirements for the Setra Power Meter product family. Please refer to the full installation and operation manual for details on all features of the meter.
Safety Information
Power Meter Quick Start Guide
Preparing for Install
Steps
What’s in the box
3/12 Load
Remove meter from box Flip open dust cover Pull front cover forward Insert screwdriver
into slot
Pivot screwdriver up to
remove main assemble
Pull down on tabs
48 Load


CT connector kit Mounting screws Wall anchors Cable ties Cal. Cert.
WARNING

!
+ +
Installation Overview
Prior to installation, the full installation and operation manual are accessible by powering up the meter through USB cable and accessing the help section on the web portal or by visiting www.setra.com
3 & 12 Load meter
Choosing conduit position
(rotate the display)
Meter wiring example
2-wire, Single Phase
48 Load meter
1. Mount unit in preferred
conduit orientation with
provided mounting screws.
(12 load housing shown)
(3 load meter only has 1 Vin)
2. After safely de-energizing
the circuit, properly wire in
the lines voltage per local
electrical codes.
3. Install the “Main assembly”
into the back housing until it
locks in place.
4. Following local electrical
codes. Wire in the current
transformers and communication
lines to the meter.
5. Install front cover by
engaging the two tabs at
the bottom and rotate the
cover until clicked in-place.
6. After meter is fully wired,
safely re-energize the circuit
and begin gathering data.
Conduit location now in the
preferred orientation
CT wiring guide
Split core CT’s
White: + Black: -
Rogowski CT’s
Red: + Black: -
Bare wire: shield
Polarity
Arrow points
towards the load
4-wire wye, 3 Phase
1 2 3
4 5 6



For additional wiring diagrams please refer to full manual.
Load
L1 L1
LoadSource Source
L2 L2
Vin CT Input
L3 L3
N
Vin CT Input
N
Vin 1
Vin 1
L1
L1
CT Input
CT Input
Conguring the meter
Connecting the meter to the PC How the “Halo-dot” works
1. Connect meter to USB cable
2. Open up web browser on your PC
3. Type http://10.10.5.2 into browser address bar
4. Complete meter setup to desired conguration and upload
to meter
Note: Meter can be powered safely via 5VDC from PC or by
line voltage. Meter setup can be completed pre or post site
installation. Full manuals can be downloaded from web portal
for more details.
This menu allows configuration of the voltage input
Click “Halo-dot” or
Near connector to begin Voltage input setup
Voltage setup menu
Expected Voltage on L1 (VAC)
480
Actual Voltage on L1 (VAC)
No voltage present
Service Type
4-wire wye
Voltage input 2
12
General Settings
• Global meter settings
• Meter identication
• Pin-code protection
Pulse I/O
• Enable pulse I/O
• Dene pulse type
• Dene scaler & width
Voltage inputs
• Dene input voltage
• Wiring conguration
• Step down PT settings
Alarm setup
• Select alarm type
• Dene alarm thresholds
• Dene alarm indication
Load setup
• ID measured loads
• Dene CT grouping
• Dene voltage input
Installation report
• Conguration record
• Initial meter readings
• Site/installer information
CT inputs
• Select CT type
• CT polarity correction
• Copy/paste CT type
Collect data
• Send data to EMS/BAS
• Locate energy losses
• Save energy
Communication
• BACnet/IP
• BACnet MS/TP
• Modbus TCP
• Modbus RTU
Visit
www.setra.com\power-meter
for full user guide and
installation manual or
call +1 978.263.1400 for
technical support or email
[email protected]
400
Navigating the meter
SS-SPM QuickStart Rev. B 2 /2020

Other Setra Systems Measuring Instrument manuals

Setra Systems MRMS User manual

Setra Systems

Setra Systems MRMS User manual

Setra Systems SRIMV Operating instructions

Setra Systems

Setra Systems SRIMV Operating instructions

Setra Systems 370 User manual

Setra Systems

Setra Systems 370 User manual

Setra Systems DATUM 2000 User manual

Setra Systems

Setra Systems DATUM 2000 User manual

Setra Systems SRIM1 User manual

Setra Systems

Setra Systems SRIM1 User manual

Setra Systems Power Patrol Manual

Setra Systems

Setra Systems Power Patrol Manual

Setra Systems 761 User manual

Setra Systems

Setra Systems 761 User manual

Setra Systems Model 730 User manual

Setra Systems

Setra Systems Model 730 User manual

Setra Systems 760 User manual

Setra Systems

Setra Systems 760 User manual

Setra Systems SRCM Installation manual

Setra Systems

Setra Systems SRCM Installation manual

Popular Measuring Instrument manuals by other brands

Mark-10 Plug & Test R01 Series user guide

Mark-10

Mark-10 Plug & Test R01 Series user guide

Mastech MS6580 user manual

Mastech

Mastech MS6580 user manual

Alentec & Orion 24720 user manual

Alentec & Orion

Alentec & Orion 24720 user manual

AEG LMG 50 Original instructions

AEG

AEG LMG 50 Original instructions

Solare Datensysteme Solar-Log 1000 manual

Solare Datensysteme

Solare Datensysteme Solar-Log 1000 manual

Schmidt DHT-3 instruction manual

Schmidt

Schmidt DHT-3 instruction manual

HT HT2236 user manual

HT

HT HT2236 user manual

sauermann DBM 620 user manual

sauermann

sauermann DBM 620 user manual

mru DELTAsmart user manual

mru

mru DELTAsmart user manual

CASTLE SONIK S operating manual

CASTLE

CASTLE SONIK S operating manual

Detecto 750EU owner's manual

Detecto

Detecto 750EU owner's manual

SatisGeo PMG-2 user manual

SatisGeo

SatisGeo PMG-2 user manual

ROOTECH ACCURA 3550 Quick setup guide

ROOTECH

ROOTECH ACCURA 3550 Quick setup guide

palintest Micro 600 manual

palintest

palintest Micro 600 manual

Fluidwell F110-A manual

Fluidwell

Fluidwell F110-A manual

Burkert Flowave 8098 quick start guide

Burkert

Burkert Flowave 8098 quick start guide

Milwaukee CD97 user manual

Milwaukee

Milwaukee CD97 user manual

Televes H30 Evolution quick guide

Televes

Televes H30 Evolution quick guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.