Seuic X4-1EF User manual

Introduction
CE,FCC and RoHS Certificate
Fixed Scanner
X4-1EF
Quick Start Guide V1.0
Read this instruction manual before using the product in order to achieve maximum performance.
After reading it, keep the manual always at hand for future reference.
The following symbols alert you to important messages. Be sure to read these
messages carefully
Safety Information for X4
WARNING
This product is not intended for use as explosion-proof product. Do not use this product in hazardous location and/or potentially explosion
atmosphere.
CAUTION
You must verify that the X4 Series are operating correctly in terms of functionality and performance before the start and the operation of the X4.
We recommend that you take substantial safety measures to avoid any damage in the event of a problem occurring.
NOTICE
SEUIC never warrant the function or performance of the X4 Series if it is used in a manner that differs from the X4 Series specifications
contained in this instruction manual of if the X4 Series are modified by yourself.
When the X4 Series is used in combination with other instruments, functions and performance maybe degraded, depending on operating
conditions and the surrounding environment.
Safety Precautions on LED Product
WARNING
Use of controls or adjustments or performance of procedures other than those specified herein may result in hazardous radiation exposure.
Do not stare into the beam.
Do not disassemble this product.
Precautions on Proper Use+
NOTICE
Do not use a voltage other than that described in the specifications with the X4 Series. Doing so may cause damage to the unit.
Be sure to turn off the power to devices attached to the X4 Series when you plug in or unplug the cables. Failure to do so may cause damage
to the X4 Series.
Do not disassemble or modify the X4 Series. Doing so may cause damage to the unit.
Place cables as far away as possible from high-voltage lines and power lines. Otherwise, electrical noise can be generated that may cause a
product failure or malfunction.
The X4 Series is a precision instrument. Do not impact or drop the instrument. Pay particular attention when transporting or installing the unit.
Do not allow water, oil, dust, or other foreign substances to stick to the scanner. This may cause read errors. Use a soft, dry cloth to wipe any
substance from the scanner. (Do not use a cloth dipped in alcohol or other cleaning agent.)
Do not turn off the power of the X4 Series while accessing files. The internal data may be corrupted.
This product complies with the following CE,FCC and RoHS andhasbeen certified by CE,FCC and RoHS.
WARNING
Indicates a hazardous situation which, if not avoided, could result in death or serious injury.
CAUTION
Indicates a hazardous situation which, if not avoided, could result in minor or moderate injury.
NOTICE
Indicates a situation which, if not avoided, could result in product damage as well as property damage.

Step
Package Contents
Model
Name
Package
content
Qty.
Appearance
X4
Fixed Scanner
Reader unit
1
Quick Start
Guide
1
Mounting
bracket
1
Option
Model
Name
Package
content
Qty.
Appearance
X4Pro-RS232&R48
5&IO_CBL
RS232
Cable
Cable
(2m/5m/10m)
1
X4Pro-RJ45PLUG_
CBL
Eth Cable
Cable
(2m/5m/10m)
1
X4Pro-USB_CBL
USB Cable
Cable
(2m/5m)
1
X4Pro-24V_CBL
Power
Adapter
Power
Adapter
1
X4-Polarizer
Attachment
Reflector
Attachment
1
X4-Window
Standard
Attachment
1
No.
Name
Description
(1)
Scanner
Section that reads codes
(2)
RS232/IO port
Port for connecting the RS232 Cable
(3)
USB/ Ethernet
port
Port for connecting the USB cable or Eth
Cable
(4)
Power LED: It turns on when the X4 is
connected to the external power supply.
Learn LED: Enter the Learn function by
pressing and holding the TUNE button
about 3s until the Learn LED is on,
Release the button and press it again to
enter the Learn function. The Learn LED
start blinking until the Image Processing
and Decoding parameters for a single
code are successfully saved in the
reader memory.
If the autolearning cannot be reached
after a few minutes, you can exit the
function by pressing the Tune button
once.
OK/NG LED
Indicates whether the reading is
possible or not.
OK: Green, ERROR: Red.
COM LED: Green LED indicates active
communication on the main port
Test Mode: Enter the Test Mode by
pressing and holding the TRIG button
about 10s until the Test LED is on, then
release the button and press it once.
When the scanner entered Test Mode,
the Bar Graph on the four LEDs is
activated and if the imager starts
reading codes the Bar-Graph shows the
Good Read Rate:
Exit the Test Mode by pressing the TRIG
button once.
(5)
TUNE
Enter the Learn function button
(6)
TRIG
Press once to read the barcode
Enter the Test Mode button(10s)
Part Names
(1)
19
(2)
19
(3)
19
(5)
(4)
19

Connecting the Serial port and control cable and wiring
1. Align the protrusion in the cable connector with the notch in the control port.
2. Tighten the connector screw by turning it clockwise.
3. Connect the wires according to usage.
(1)NPN wiring
Serial port and I/O cable

NOTICE
Be sure to turn power off before attempting to connect or disconnect the control cable.
Insert the connector straight so that it is not tilted and then tighten it securely. Under-tightening can lead
to a loose connector due to vibrations, resulting in poor contact.
Insulate unused wires individually
(2)PNP wiring
(3)Output wiring (signal tower light)

2. Tighten the connector screw by turning it clockwise.
Connecting the Ethernet cable or USB cable
1. Align the protrusion in the cable connector with the notch in the Ethernet(USB) port and
connect the cable to the main unit.

Distance(mm)
2D
Distance
(mm)
1D
50 - 83
2mil
50-230
3.3mil
50-125
3.3mil
45-400
5mil
50-230
5mil
45-560
7.5mil
45-450
10 mil
40-600
10mil
40-600
20 mil
Mounting Methods
1. Secure the X4 unit with screws.
(Mounting screws are included in the package)
2. When using the mounting bracket
Field of View and Installation Distance
Distance(mm)
Field of View(mm)
50
21
50
100
47
100
180
77
180
310
132
310
350
149
350
450
192
450
ETH or USB cable

Model
X4-1EF
Receiver
Sensor
CMOS Image Sensor with global shutter
Number of pixels
1.3M,1280 x 1080
Light emitter
Light source
High-intensity red LED and blue LED
Aimer
Laser dual-point positioning aimer Class II
Focus adjustment
Automatic
Reading
specifications
Supported
symbol
1D
Code128,GS1 128,Code39,Code93,codabar,2of5 (Industrial 2of5),EAN/UPC
2D
QR、DataMatrix(ECC200)、PDF417、Micro PDF417
Minimum
resolution
1D
3.3mil
2D
2.0mil
Reading distance
50mm to 450mm
I/O
specifications
Control
input
Points
2
Input type
Bidirectional voltage input
Maximum rating
30V
Minimum ON voltage
<4V
Maximum OFF current
0.001A
Control
output
Points
3
Output type
3 optocoupler output
Maximum rating
30V
Maximum load current
1 output: 50 mA or less, 3-output total: 100 mA or less
Leakage current when OFF
0.1 mA or less
Residual voltage when ON
1 V or less
Ethernet
Supported protocol
TCP/UDP
Serial
communication
Communication speed
115200/57600/38400/19200/9600 bps
Supported protocol
RS232/RS485
USB
Communication
standard
USB 2.0 Full Speed compliant
Environmental
Resistance
Enclosure rating
IP65
Ambient temperature
0° to 50°C
Ambient storage temperature
-20°C to 70°C
Relative humidity
5 to 95% RH (No condensation)
Storage ambient humidity
5 to 95% RH (No condensation)
Ambient light
0 to 10000 lux
Operating environment
No dust or corrosive gas present
Rating
Power supply voltage
10 to 30V DC
Current consumption
0.5 to 1.5 A
Weight
Approx.215 g
Dimensions(L x W x H)
61.2 mm x 48.7 mm x 43.8 mm
Specifications

Dimensions

Interface Settings
TCP-Server TCP-Client
RS-232 RS-485
USB COM USB HID
Product Quick Configuration Codes

You can download technical documents useful for product introduction and operation.
2023 SEUIC Company. All Rights Received.
SEUIC Technologies Co., Ltd.
Company address: NO.15 Xinghuo Road, Nanjing New High Technology Industry
Development Zone, 210061, Nanjing City, Jiangsu Province, China.
Company official website:www.seuic.com
Product website:www.chinaautoid.net
Mailbox:AUTOID@seuic.com
Postocde:210061
Service Hotline:0086-400-677-0876
Technical Support
Table of contents
Other Seuic Scanner manuals