Shark 100B User manual

Doc# E145752 V.1.04 QS - 1
Shark® 100B Quickstart
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Shark® 100B Meter Quickstart Guide
Mechanical Installation
Electrical Installation: Select diagram for your application.
NOTE: Other wiring configurations are available. See the full Manual on the enclosed CD.
DIN mounting
bracket
Top mounting
bracket groove
Bottom
#8 screw
Remove (unscrew)
ANSI studs for
DIN installation
Meter in
NEMA12
mounting
gasket
DIN Mounting brackets
92mm Square
form
Remove (unscrew) ANSI studs
for DIN installation
DIN Installation
4.0” Round form
ANSI Studs
ANSI Installation
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
3 x 0.1A
FUSE
3A
C
C
B
B
A
A
N
N
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
3 x 0.1A
FUSE
3A
C
C
B
B
A
A
N
N
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
2 x 0.1A
FUSE
3A
C
C
B
B
A
A
WYE direct, 3
phase, 4 wire
Delta direct, 3
phase, 3 wire
lc
HI
LO
lb
HI
LO
la
HI
LO
Earth Ground
L(+)
Power
Supply
Connection
N(-)
L(+)
GND
N(-)
Vref
Va
Vb
Vc
LINE
LOAD
CT
Shorting
Block
FUSES
3 x 0.1A
FUSE
3A
C
C
B
B
A
A
NOTE: Do not overtighten nuts. The maximum installation torque is 0.4 Newton-Meter.
WYE with PTs,
3 phase, 4 wire
Delta with PTs, 3
phase, 3 wire
Doc# E145752 V.1.04 QS - 2
Shark® 100B Quickstart
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Program Settings Using the Faceplate Buttons:
(MENU, ENTER, DOWN ARROW, RIGHT ARROW)
See the figure on the right for the location of the
faceplate buttons.
Access Configuration Mode:
1.Push the MENU button - you will see
the display on the right; rSt will be
blinking.
2.Press the DOWN ARROW once.
CFG (Configuration) moves to the
top of the display.
3.Press the ENTER button. You will
see the Configuration menu, shown
on the right.
4.Press the DOWN ARROW and then press the ENTER button. You will see the CT
numerator setting screen (Ct-n). The current CT numerator is shown in the second
line. To change the setting, press the DOWN ARROW until the value you want is
displayed. Then press the RIGHT ARROW to move to the next digit. Repeat until
the setting is done.
5.Press the ENTER button to go to the CT denominator screen (CT-d). This setting is
display only - it can’t be changed.
6.Press the ENTER button to go to the CT Scaling setting screen (CT-S). The current
Scaling is shown in the second line. Press the DOWN ARROW to choose another
value. You can choose 1, 10, or 100.
7.Press the ENTER button to go to the PT numerator setting screen (Pt-n).The current
PT numerator is shown in the second line. To change the setting, press the DOWN
ARROW until the value you want is displayed. Then press the RIGHT ARROW to
move to the next digit. Repeat until the setting is done.
8.Press the ENTER button to go to the PT-denominator screen (Pt-d). The current
PT denominator is shown in the second line. To change the setting, press the DOWN
ARROW until the value you want is displayed. Then press the RIGHT ARROW to
move to the next digit. Repeat until the setting is done.
9.Press the ENTER button to go to the PT Scaling setting screen (PT-S). The current
Scaling is shown in the second line. Press the DOWN ARROW to choose another
value. You can choose 1, 10, 100, or 1000.
NOTE: See example CT and PT Settings beginning on the next page.
0.659
0000
-
-
-
A
B
C
MENU ENTER
MAX
MIN
LM1
LM2
%THD
PRG
VOLTS L-N
VOLTS L-L
AMPS
W/VAR/PF
VA/H z
lrDA
Wh
VARh
VAh
120%-
90%-
60%-
30%-
%LOAD
MEGA
KILO
Wh Pulse
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
Doc# E145752 V.1.04 QS - 3
Shark® 100B Quickstart
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
10.Press the ENTER button to go to the Connection setting screen (Cnct). The current
setting is shown in the second line. Press the DOWN ARROW to choose another
value. You can choose 3 EL (element) WYE, 2 Ct del (Delta), or 2.5 EL WYE.
11.Press the ENTER button four times. (You will pass through the Address, Baud Rate,
and Protocol screens. You DO NOT change any of the settings on these
screens.**You will see the Scroll setting screen (SCrL). The current setting is
shown in the second line. Press the DOWN ARROW to choose another setting.
You can choose YES (the meter readings will scroll on the display) or no (the meter
readings will not scroll on the display).
12.Press the MENU button twice. You will see the Store Settings screen (Stor ALL?).
The default setting is YES. To save the settings you’ve made, press the ENTER
button. You will see the confirmation screen (Stor ALL done) and then the meter
resets.
NOTE: If you do not want to save your settings, press the RIGHT ARROW. YES
changes to no. Press the ENTER button.
Example CT Settings:
200/5 Amps: set the Ct-n value as 200, Ct-S value as 1.
800/5Amps: set the Ct-n value as 800, Ct-S value as 1.
2000/5 Amps: set the Ct-n value as 2000, Ct-S value as 1
10,000/5 Amps: set the Ct-n value as 1000, Ct-S value as 10.
Example PT Settings:
14400/120 Volts: set the Pt-n value as 1440, Pt-d value as 120, Pt-S value as 10.
138000/69 Volts: set the Pt-n value as 1380, Pt-d value as 69, Pt-S value as 100.
345000/115 Volts: set the Pt-n value as 3450, Pt-d value as 115, Pt-S value as 100.
345000/69 Volts: set the Pt-n value as 345, Pt-d value as 69, Pt-S value as 1000.
**The default communication settings are Address 001, Baud Rate 57.6, and Protocol Mod rtU
(Modbus RTU). In the event that the communication settings are accidentally changed, change them
back to these default values.
NOTE: For additional wiring options, programming screens, and instructions on using the Shark®
100B’s BACnet®*, refer to the Shark® 100/100T/100B Meter Installation and Operation Manual and
the CommunicatorPQATM, MeterManagerPQATM, and EnergyPQA.comTM Software User Manual on the
enclosed CD.
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
A
B
C
-
-
-
MENU ENTER
Shark® is a registered trademark of Electro Industries/GaugeTech. The distinctive shape, style, and overall appearance of the Shark®
meter is a trademark of Electro Industries/GaugeTech.
*BACnet is a registered trademark of ASHRAE.
Doc# E145752 V.1.04 QS - 4
Shark® 100B Quickstart
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
Electro Industries/GaugeTech
The Leader In Power Monitoring and Smart Grid Solutions
This page intentionally left blank.

Other Shark Measuring Instrument manuals

Shark MP200 User manual

Shark

Shark MP200 User manual

Shark 100BT User manual

Shark

Shark 100BT User manual

Shark 200 User manual

Shark

Shark 200 User manual

Shark 50 User manual

Shark

Shark 50 User manual

Shark 200 User manual

Shark

Shark 200 User manual

Shark 250 User manual

Shark

Shark 250 User manual

Shark 200T User manual

Shark

Shark 200T User manual

Popular Measuring Instrument manuals by other brands

Scott Protege SG user guide

Scott

Scott Protege SG user guide

APG PG-7 Operator's manual

APG

APG PG-7 Operator's manual

Sierra InnovaMass 240 series instruction manual

Sierra

Sierra InnovaMass 240 series instruction manual

Benning CM 9-2 operating manual

Benning

Benning CM 9-2 operating manual

Monarch PLT200 instruction manual

Monarch

Monarch PLT200 instruction manual

TESA TESATRONIC TT20 instruction manual

TESA

TESA TESATRONIC TT20 instruction manual

Agilent Technologies 16517A User reference

Agilent Technologies

Agilent Technologies 16517A User reference

Bender RCMB330 quick start guide

Bender

Bender RCMB330 quick start guide

Eclipse EGA4 user manual

Eclipse

Eclipse EGA4 user manual

Tektronix RSA5103 Service manual

Tektronix

Tektronix RSA5103 Service manual

sparklike Laser Portable 2.1 Setup guide

sparklike

sparklike Laser Portable 2.1 Setup guide

Chauvin Arnoux C.A847 user manual

Chauvin Arnoux

Chauvin Arnoux C.A847 user manual

janitza UMG 103 Installation and putting into service

janitza

janitza UMG 103 Installation and putting into service

KAEL Muhendislik Elektronik ENERGY 11-DIN instruction manual

KAEL Muhendislik Elektronik

KAEL Muhendislik Elektronik ENERGY 11-DIN instruction manual

Simrad FX80 Harbour Acceptance Test

Simrad

Simrad FX80 Harbour Acceptance Test

Ulvac MBD-D instruction manual

Ulvac

Ulvac MBD-D instruction manual

SICK MAIHAK MaihakMBA 200 operating instructions

SICK MAIHAK

SICK MAIHAK MaihakMBA 200 operating instructions

Prismatibro Prisma DI-5C manual

Prismatibro

Prismatibro Prisma DI-5C manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.