Shihlin electric EC207 User manual

Easy use Easy read
To prevent a EC207 unit malfunction due to excessive noise, isolate all EC207
input/output signal lines from all power wiring or power cables via a separate
wiring duct.
Be sure all cable connectors are securely attached to the EC207 unit.A loose
connection may cause incorrect input or output signals.
Be sure to ground the EC207 unit’s FG wire separately from other equipment
FG lines. Also, be sure to use a grounding resistance of 100. or less and a
2mm2or thicker wire, or your country’s applicable standard. Otherwise, electric
shock or malfunctions may result.
Be sure to use only the designated torque to tighten the EC207 unit’s terminal
block screws. If these screws are not tightened firmly, it may cause a
short-circuit, fire or incorrect unit operation.
Be sure that metal particles and wiring debris do not fall inside the EC207 unit.
They can cause a fire, malfunction or incorrect unit operation.
Be sure to read the EC207 unit’s manual carefully before performing program
changes, entering forced output, or using the RUN, STOP, or PAUSE
commands while the EC207 is operating. Mistakes made when usingthese
items can cause machine accidents or damage.
Warning
To prevent electrical shock or equipment damage, unplug the EC207 unit’s
power cord from the power supply prior to installing or wiring the EC207.
After completing any EC207 wiring work, be sure the terminal block’s
protective plastic cover is reattached. If this cover is not reattached, an
electrical shock could easily occur.
To prevent an electric shock be sure to disconnect your EC207 unit’s power
cord from the power supply before wiring the EC207.
Do not use voltage beyond the EC207 unit’s specified range. Doing so may
cause a fire or an electric shock.
The cables connected to the EC207 should be secured by cable clamps to
prevent weight or tension of the cables added to the connectors or terminals.
The EC207 unit’s wiring should be checked to confirm that both the operating
voltage and wiring terminal locations are correct. If either the voltage or the
wiring terminal location is incorrect, it can cause a fire or accident.
Do not connect or disconnect Host and EC207 unit communication cables
while the EC207 is turned ON.
Do not replace the EC207 unit’s battery yourself. The EC207 uses a lithium
battery for backing up its internal clock data and the battery may explode if it is
replaced incorrectly. When replacement is required, please contact your local
EC207 distributor.

I. Specifications
General Specifications
Item EC207-CT-00 EC207-CT-11
Display color 64K colors
Screen type TFT LCD
Screen size 7
Resolution W x H
(dots) 800× 480
Display angle (Vertical) - 70° to + 50°
Display
angle(Horizontal) - 70° to + 70°
Intensity of LCD only
(cd/m2) 300
Back light off
automatically Always ON, Random Setting
Display section
Backlight LED (Life approx. 30000h / 25℃)
Touch Control Panel 4-wire resistive
Type Analog Resistance Film Type
Touch Resolution 2mm and above
Life 1 million times Min
Hardness of surface 4H
Touch panel
The Number of Switch
Can Be Set
(Number/Screen)
960(40X24)
Text
TrueType Font
Support Unicode
Interface Specifications
Serial COM Port
COM1/COM2 (RS-232C / RS422/RS485),COM3(RS-232C),
Ethernet
1. COM1、COM2 and COM3 port Baud Rate、Data
Length、Parity and Stop Bit can be set on the HMI.
2. COM1、COM2 及COM3 three types of communication
ports that can be used simultaneously.
3. Supporting various brands’PLC models as well as
Shihlin inverters、Shihlin thermostats and Shihlin
SERVO.
4. RS-485 When selecting MODBUS communication, as
many as 31 sets can be connected by setting the station
number from 1 to 31.
5. Communicated with PLC via Ethernet. ※(1)
6. COM1(RS-232C) can be connected with the Barcode
Scanner.
Data transfer
(PC - HMI)
USB, Ethernet:Project data upload/download ,OS
installation. ※(2)
Interface
Several HMI
connection Ethernet. ※(2)
Memory Expansion ※(3) SD Card and USB
(1)『Ethernet Multifunctional』support for Mitsubishi FX3U-ENET and QJ71E71-100
module.
(2)『Ethernet Multifunctional』support for Ethernet port.
(3) SD Card Maximum 16G SDHC Support.
USB Maximum 16G Support.

General Specifications
Input Voltage DC 24V
Rated Voltage DC 24V ± 10%
Range for
Instantaneous Stop Within 10ms
Power
Power Consumption 15W(Max)
Operating Ambient
Temp. 0℃~ 45℃
Storage Ambient
Temp. -20℃~ 60℃
Operating Ambient
Humidity 10%~85%RH (An Environment without Condensation)
Environmental
Tolerance Non-corrosive Environment; Non-conductive Environmen
Vibration
Resistance
IEC 61131-2 Compliant,Vibration frequency:5~150Hz,
Acceleration:9.8m/s2(1.0G),X,Y,Z directions for 12
times
Physical
Noise Resistance Compliant with IEC61000-6-2:2001
Grounding D Class Grounding
Water Resistance Front: IP65 (Dust-proof/Anti-drop Design); Back: IP20
Cooling Method Natural Cooling
Weight 0.85kg
Exterior Dimensions
W×H×D(mm) 200x146x42.5
Installation
Hole-cutting Size
(mm) 192x138

II、Part Names
(1)
(3)
(2)
Front:
No Name Description
1 Display
screen
Displays the Utility and the user creation
screen.
Bottom:
Power LED:When power is turned on.
Run LED:Screen run.
2 LED
Alarm LED:Communication Error.
No Name Description
3 SD card interface For installing SD card

(4)
1
234
5
6
789
(5)
型號 : EC207-CT-00
額定值 : DC +24V Class 2/500mA
生產工令 :
生產序號 : SLHO000001
MADE IN TAIWAN
L10M0001
R00001
地址 : 新竹縣新豐鄉中崙村七鄰二三四號
電話 :(03)599-5111
人 機 介 面
(6)
(7)
(8)
PIN definition of serial communication:
(9) (10) (11) (12)
Back:
No Name Description
4 Battery Holder Houses the Battery
5 USB Device
interface For connecting a PC.
6 Ethernet interface The Ethernet transmission interface
7 Sound interface
Sound output,support for Sound play
8 USB Host interface For installing USB storage Device
9 Power terminal DC24V
10 COM1 RS232C / RS422 / RS485
11 COM2 RS232C / RS422 / RS485
12 COM3 RS232C
PIN NO. COM1 COM2 COM3
1 TX+ / A TX+ / A -
2 TX TX TX
3 RX RX RX
4 RX+ RX+ -
5 GND GND GND
6 RX- RX- -
7 RTS - RTS
8 CTS - CTS
9 TX- / B TX- / B -
RS-232:TX/RX/CTS/RTS/GND
RS-422:TX+/TX-/RX+/RX-
RS-485:A/B

III、External Dimensions IV、EU200 Series Model Name Indication
Depending on the type of connection cable used the dimensions
shown above will change. The dimensions given here are
representative values and are intended for reference only.
NO Description
1 EC200 series
2 7”Display Screen size
3 Colors TFT LCD
4 00:Standard Type
11:High-Performance Type

V、Installation
Make an installation hole on the control panel the dimensions shown
below.(Unit: mm)
Max torque:0.3 Nm (2.65 lb-in).

、VI Connecting the Power Cord
型號 : EC207-CT-00
額定值 : DC +24V Class 2/500mA
生產工令 :
生產序號 : SLHO000001
MADE IN TAIWAN
L10M0001
R00001
地址 : 新竹縣新豐鄉中崙村七鄰二三四號
電話 :(03)599-5111
人 機 介 面
T
design of the system/connection does not produce a shorting loop.
o avoid an electric shock, prior to connecting the EC207 unit’s power
cord terminals to the power terminal block, confirm that the EC207
unit’s power supply is completely turned OFF, via a breaker, or similar
unit.
Supplying a power voltage other than that specified will damage the
power source and the EC207 unit.
Since there is no power switch on theEC207 unit, be sure to attach
breaker-type switch to its power cord. a
When the FG terminal is connected, be sure the wire is grounded.
Not grounding the EC207 unit will result in excess noise and vibration.
The SG and FG terminals are connected internally in the EC207 unit.
When connecting the SG wire to another device, be sure that the
Bt
ctric communication
components of the human machine interface.
It is recomm
efore plugging or unplugging the power terminal, make sure to cu
off the power supply or it may damage the ele
ended that the user add a core to the input terminal of the
power line.
This manual suits for next models
1
Table of contents
Other Shihlin electric Control Panel manuals
Popular Control Panel manuals by other brands

Amplicon
Amplicon EX213 instruction manual

Autronica
Autronica AutroSafe BS-60 Operator's handbook

ALCO
ALCO 4000 Series user manual

Siemens
Siemens Synco RMZ792 installation instructions

elsner elektronik
elsner elektronik KNX eTR 208 Technical specifications and installation instructions

Kampmann
Kampmann KaController 3210001 quick guide