
If control by DMX, follow below steps:
a) Connect a power cable to the POWER IN socket of CIRCLE FLAMER X-F1800. Connect the other end
of power cable to the power source. Make sure power supply in consistent with the rated voltage of
the equipment, and the socket must well grounded.
b) Each unit of CIRCLE FLAMER X-F1800 can be connected to power supply directly. If connect
machine in sequence, please connect a power link cable to the POWER OUT of previous machine,
connect the other end of the power link cable to POWER IN of the next machine. Do not connect
exceed units to a single electrical circuit.
c) Power on CIRCLE FLAMER X-F1800
d) Assign a DMX address for each unit of machine. If use SHOWVEN host controller or FXcommander
to control the machine please allocate a unique DMX address for each unit of machine.
e) Connect a DMX cable to the DMX IN socket of first unit of X-F1800, another head of this DMX cable
connect to DMX console (such as FXcommander). Make sure the DMX console is powered off.
f) Connect a DMX cable to the DMX OUT socket of previous X-F1800, and the other end to the DMX
IN of next machine. Connect all devices in series in this way.
g) Suggest to plug in a DMX terminator into the DMX OUT in last unit of machine to improve signal
reliability. Signal amplifier is required for long distance (>200m) DMX signal transmission.
If control by 9-60V pyro signal, follow below steps:
a) Connect a power cable to the POWER IN socket of CIRCLE FLAMER X-F1800. Connect the other end
of power cable to the power source. Make sure power supply in consistent with the rated voltage of
the equipment, and the socket must well grounded.
b) Each unit of CIRCLE FLAMER X-F1800 can be connected to power supply directly. If connect
machine in sequence, please connect a power link cable to the POWER OUT of previous machine,
connect the other end of the power link cable to POWER IN of the next machine. Do not connect
exceed units to a single electrical circuit.
c) Connect the power control cables to the 9-60V pyro signal connector on CIRCLE FLAMER X-F1800.
d) Connect the other end of power control cables to the pyro controller (9-60V external trigger source).
Make sure the pyro controller is powered off
e) Power on all CIRCLE FLAMER X-F1800
f) Set the Ext Ignite to ON status in advanced interface, set the firing sequence by choose a sequence
No. at Set Ext Sequence.
4. Power ON the DMX console or pyro controller
5. Programming
Program the CIRCLE FLAMER X-F1800 with DMX console.
6. Test the ignition function of CIRCLE FLAMER X-F1800
Test the ignition function of CIRCLE FLAMER X-F1800, we can check whether the igniters of each unit
of X-F1800 is working fine. Due to the safety switch is stay at TEST MODE the pump won’t work, there
will be only ignition while no fuel spray out, so no flames generated.
7. Fill the CIRCLE FLAMER X-F1800
Please fill the machine with qualified fuel. The fuels suggested on CIRCLE FLAMER are ISOPAR,
ISOPROPANOL, please make sure water content in fuel should less than 0.5%.
8. Firing
a) Double confirm the prescribed safety isolation zone is clear, no person, animal or other property
within this region.
b) Switch the safety switch of CIRCLE FLAMER X-F1800 to USER MODE.
c) Pressurize CIRCLE FLAMER X-F1800.