ΔForeword
Thanks for choosing SHOWVEN PyroSlave X16, we wish it will bring you lots of exciting moments. Please
read the following manual carefully before operating this product. Operate according to instructions is
very important for safety, and can elongate the service life of the machine
Strictly follow the instruction in the manual when operate PyroSlave X16. If you have any doubts, please
We assume the person who use or come in contact with the device are familiar with how the device and
fireworks should be handled. This includes proper use, maintenance and repair of the machine as defined
in this user manual.
ΔWarning
\This product can only be operated by persons of legal age. And is only suitable for qualified operators.
Operators should obtain the corresponding local professional technical certificates or qualifications
before operate this system.
\Make sure all legal requirements for the performance of display fireworks, stage fireworks and special
effects are met in the respective country of use.
\Make sure that the required safety distance to persons or flammable objects are maintained according
to the related firing objects.
\If there are flame head or fireworks have been connected to the salve, before we check the salve status
on FXcommander all personnel should be cleared from the danger area. For fireworks the safety
distance is according to local laws and regulations.
\It is recommended to use at least 1.5mm double-core stranded wire for the bus. It is required to
distinguish between positive and negative.
\It is recommended to use fireproof and frost-resistant cables for the bus. The flame-retardant material
will prevent the cable from igniting in an open flame, thereby greatly reducing the probability of bus
short-circuit due to fire. The antifreeze property of the bus can ensure that the bus is still soft in a low
temperature environment.
\If the bus is close to fire-prone areas (such as next to cakes), in order to avoid the bus being ignited and
causing a short circuit, it is recommended to wrap the bus in these areas with tin foil.
\No matter wireless or wired mode, please always install battery for slaves.
\The device shall not be altered and applied to other use purpose.
ΔProduct Description
PyroSlave X16 is a 16-channel firework igniter specially designed for pyro technician and stage special
effects professionals. In order to adapt to extreme outdoor applications, PyroSlave X16 equipped with
robust aluminum housing, touch keys, metal connection terminals. PyroSlave X16 can be operated both
wired and wireless. Wireless mode with dual band antennas communicate simultaneously, preventing
signal interference on a single frequency band. The 2-wire PBUS technology used in wired communication
can realize power supply while communicating.
ΔFunctional Characteristics
\Robust aluminum housing and metal connection terminals, waterproof and dustproof as well as
prevent the impact of sparks drop from fireworks.
\Can be operated both wired and wirelessly
\Wired mode with 2-wire PBUS technology can realize power supply while communicating, ensure
continuous working
\Wireless mode with dual band antennas communicate simultaneously, preventing signal interference
on a single frequency band.