STORM 33A / SWITCH 22A
ASSEMBLY MANUAL
Control button
Rose
Lift rod
Blocking clip
Plug
Plug nut
Cistern seal
Plug seal
Seal
Overflow
Stirrup
Réf. 5539 - Imprimerie PONS s.a.
a
b
c
d
e
f
g
h
i
j
k
GB
I - PREPARATION OF THE MECHANISM
II - INSTALLATION
 Check the positioning of the stirrup
if the stirrup (k) is positioned correctly
with reference to the table below, move
on to step ➑; otherwise, go through all
the following steps in order:
➊ Unclip the lift rod (c)
➋ Remove the 2 grey blocking clips (d)
➌ Remove the stirrup (k)
➍ If necessary, cut the overflow (j) as shown
in the table
➎ Set the stirrup (k) in the suitable
notch - see table
➏ Clip the 2 grey blocking clips (d) back in
place
➐ Clip on the lift rod (c)
➑ Unscrew the plug nut (f)
Measure the cistern:
- H (from top of lid to inside bottom of cistern)
- D (diameter of hole in lid)
Height of cistern H
Diameter D Diameter D
of hole of hole
in lid from in lid from
16 to 36 mm &
37 to 42 mm
43 to 50 mm
1* 307 to 325 325 to 343
2* 326 to 340 344 to 358
3 341 to 355 359 to 373
4 356 to 370 374 to 388
5 371 to 385 389 to 403
6 386 to 400 404 to 418
Stirrup adjusting notch
H
D
➌
➊
➍
Stirrup notch Overflow
1 Cut between e and f
2 Cut between b and c
Position the mechanism
in the cistern and attach
it with the nut (f).
➎
➐
➏
Blocking clips
➋
Bottom of tank
Cistern wall
Screw M6x78
Tapered joint
Hexagonal nut
Washer
Wing nut
Washer
IV - ADJUSTMENT OF WATER LEVEL
III - ASSEMBLY OF CISTERN TANK
V - INSTALLING THE BUTTON
VI - MAINTENANCE
➊ Attach the screws to the
bottom of the cistern (see
stack of parts indicated
below
➋ Position the foam seal on
the nut (f)
➌ Position the cistern
on the toilet bowl and
attach it with the wing
nuts
Replacement of the seal
➊ Open the cistern and turn the mechanism a
quarter turn to separate it from the plug
➋ Remove the seal attaching clip
➌ Replace the seal
➍ Fit the clip then relocate the mechanism,
locking it on the plug
➎ Close the cistern making sure that the control
button is correctly assembled (see § V)
Seal
Clip
Plug
First connect your float valve to the water system, open
the stop valve and adjust the Full flush level using the
float valve (see on back).
NB: the maximum water level should be 20 mm below
the overflow (j).
➊ Fit the lid
➋ If the lid hole (D) is < 37 mm or > 42, remove the
rose (b)
➌ Position the button on the lid and screw down
(without pushing the central part) until it locks.
N.B. :
For mechanism Switch
(Ref. 22A)
Push once to flush.
Push again to interrupt.
Overflow
maximum
water level
20 mm
INSTALLING THE FLOAT VALVE
ROBECO 06 and STANDARD 15EL
COMPACT 95L
MAINTENANCE (95L & 99B)
COMPACT 99B and HANDY 93B
4, quai Antoine 1er - BP 219 - MC 98007 MONACO Cedex
Tél. 00 377 93 15 53 75 - Fax : 00 377 92 05 71 04 - E-mail: contact@siamp.com
➊ Position valve
➋ Fasten with nut
➌ Connect to water supply
➍ Adjust water level with the adjustment screw
➊ Position valve
➋ Fasten with nut
➌ Connect to water supply
➍ Adjust water level with the adjustment screw
(15 EL) or by bending the rod (06)
Adjustment screw Adjustment screw
Insert rod
as far as
possible Locking
nut
Locking
nut
Fiber gasket
Fiber gasket
Adjustment screw
Locking nut
Fiber
gasket
Locking
nut
Gasket/filter
Filter
Membrane
Membrane
N.B. Ensure tightness of
connection to cistern with fiber
gasket, without the use of any
corrosive joint compound N.B. Ensure tightness of connection to cistern with
fiber gasket, without the use of any corrosive joint
compound
N.B. Ensure
tightness of
connection to
cistern with filter
gasket, without the
use of any corrosive
joint compound
Adjustment screw

This manual suits for next models

1

Other Siamp Control Unit manuals

Siamp Optima 50 User manual

Siamp

Siamp Optima 50 User manual

Siamp 99T series User manual

Siamp

Siamp 99T series User manual

Siamp STORM 33A User manual

Siamp

Siamp STORM 33A User manual

Popular Control Unit manuals by other brands

COBHAM C-5000D P-25 quick reference

COBHAM

COBHAM C-5000D P-25 quick reference

National Instruments NI TB-4340 user guide

National Instruments

National Instruments NI TB-4340 user guide

Zte AD3812 Command manual

Zte

Zte AD3812 Command manual

Neol ePowerSwitch 8G user guide

Neol

Neol ePowerSwitch 8G user guide

BENDIX E-5 BRAKE VALVE manual

BENDIX

BENDIX E-5 BRAKE VALVE manual

Taoglas EDGE Locate quick start guide

Taoglas

Taoglas EDGE Locate quick start guide

ABB FEPL-02 Ethernet POWERLINK Quick installation and start-up guide

ABB

ABB FEPL-02 Ethernet POWERLINK Quick installation and start-up guide

SPI Lasers redPOWER quick start guide

SPI Lasers

SPI Lasers redPOWER quick start guide

ZIEHL-ABEGG UNIcon MODBUS Master operating instructions

ZIEHL-ABEGG

ZIEHL-ABEGG UNIcon MODBUS Master operating instructions

CTC Union Expansion EnergyFlex Installation and maintenance manual

CTC Union

CTC Union Expansion EnergyFlex Installation and maintenance manual

Watts LFUSG-B-M1 installation instructions

Watts

Watts LFUSG-B-M1 installation instructions

M-system M6DXF1 manual

M-system

M-system M6DXF1 manual

Flowserve GESTRA GAV 54F Installation & operating instructions

Flowserve GESTRA

Flowserve GESTRA GAV 54F Installation & operating instructions

Sony PDBK-L1500 installation manual

Sony

Sony PDBK-L1500 installation manual

ICP DAS USA I-7063 quick start guide

ICP DAS USA

ICP DAS USA I-7063 quick start guide

Doepke Dupline DRO 4 operating instructions

Doepke

Doepke Dupline DRO 4 operating instructions

Numato Lab Galatea IP4776CZ38 user guide

Numato Lab

Numato Lab Galatea IP4776CZ38 user guide

ABB Relion 670 series Commissioning manual

ABB

ABB Relion 670 series Commissioning manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.