STORM 33A / SWITCH 22A
ASSEMBLY MANUAL
Control button
Rose
Lift rod
Blocking clip
Plug
Plug nut
Cistern seal
Plug seal
Seal
Overflow
Stirrup
Réf. 5539 - Imprimerie PONS s.a.
a
b
c
d
e
f
g
h
i
j
k
GB
I - PREPARATION OF THE MECHANISM
II - INSTALLATION
 Check the positioning of the stirrup
if the stirrup (k) is positioned correctly
with reference to the table below, move
on to step ➑; otherwise, go through all
the following steps in order:
➊ Unclip the lift rod (c)
➋ Remove the 2 grey blocking clips (d)
➌ Remove the stirrup (k)
➍ If necessary, cut the overflow (j) as shown
in the table
➎ Set the stirrup (k) in the suitable
notch - see table
➏ Clip the 2 grey blocking clips (d) back in
place
➐ Clip on the lift rod (c)
➑ Unscrew the plug nut (f)
Measure the cistern:
- H (from top of lid to inside bottom of cistern)
- D (diameter of hole in lid)
Height of cistern H
Diameter D Diameter D
of hole of hole
in lid from in lid from
16 to 36 mm &
37 to 42 mm
43 to 50 mm
1* 307 to 325 325 to 343
2* 326 to 340 344 to 358
3 341 to 355 359 to 373
4 356 to 370 374 to 388
5 371 to 385 389 to 403
6 386 to 400 404 to 418
Stirrup adjusting notch
H
D
➌
➊
➍
Stirrup notch Overflow
1 Cut between e and f
2 Cut between b and c
Position the mechanism
in the cistern and attach
it with the nut (f).
➎
➐
➏
Blocking clips
➋
Bottom of tank
Cistern wall
Screw M6x78
Tapered joint
Hexagonal nut
Washer
Wing nut
Washer
IV - ADJUSTMENT OF WATER LEVEL
III - ASSEMBLY OF CISTERN TANK
V - INSTALLING THE BUTTON
VI - MAINTENANCE
➊ Attach the screws to the
bottom of the cistern (see
stack of parts indicated
below
➋ Position the foam seal on
the nut (f)
➌ Position the cistern
on the toilet bowl and
attach it with the wing
nuts
Replacement of the seal
➊ Open the cistern and turn the mechanism a
quarter turn to separate it from the plug
➋ Remove the seal attaching clip
➌ Replace the seal
➍ Fit the clip then relocate the mechanism,
locking it on the plug
➎ Close the cistern making sure that the control
button is correctly assembled (see § V)
Seal
Clip
Plug
First connect your float valve to the water system, open
the stop valve and adjust the Full flush level using the
float valve (see on back).
NB: the maximum water level should be 20 mm below
the overflow (j).
➊ Fit the lid
➋ If the lid hole (D) is < 37 mm or > 42, remove the
rose (b)
➌ Position the button on the lid and screw down
(without pushing the central part) until it locks.
N.B. :
For mechanism Switch
(Ref. 22A)
Push once to flush.
Push again to interrupt.
Overflow
maximum
water level
20 mm
INSTALLING THE FLOAT VALVE
ROBECO 06 and STANDARD 15EL
COMPACT 95L
MAINTENANCE (95L & 99B)
COMPACT 99B and HANDY 93B
4, quai Antoine 1er - BP 219 - MC 98007 MONACO Cedex
Tél. 00 377 93 15 53 75 - Fax : 00 377 92 05 71 04 - E-mail: contact@siamp.com
➊ Position valve
➋ Fasten with nut
➌ Connect to water supply
➍ Adjust water level with the adjustment screw
➊ Position valve
➋ Fasten with nut
➌ Connect to water supply
➍ Adjust water level with the adjustment screw
(15 EL) or by bending the rod (06)
Adjustment screw Adjustment screw
Insert rod
as far as
possible Locking
nut
Locking
nut
Fiber gasket
Fiber gasket
Adjustment screw
Locking nut
Fiber
gasket
Locking
nut
Gasket/filter
Filter
Membrane
Membrane
N.B. Ensure tightness of
connection to cistern with fiber
gasket, without the use of any
corrosive joint compound N.B. Ensure tightness of connection to cistern with
fiber gasket, without the use of any corrosive joint
compound
N.B. Ensure
tightness of
connection to
cistern with filter
gasket, without the
use of any corrosive
joint compound
Adjustment screw

This manual suits for next models

1

Other Siamp Control Unit manuals

Siamp Optima 50 User manual

Siamp

Siamp Optima 50 User manual

Siamp 99T series User manual

Siamp

Siamp 99T series User manual

Siamp STORM 33A User manual

Siamp

Siamp STORM 33A User manual

Popular Control Unit manuals by other brands

getAir LED Installation & user guide

getAir

getAir LED Installation & user guide

Cisco T1 Configuration guide

Cisco

Cisco T1 Configuration guide

Maruson MBS-610RM quick guide

Maruson

Maruson MBS-610RM quick guide

Zeta FYREYE MKII ZASC-MI installation guide

Zeta

Zeta FYREYE MKII ZASC-MI installation guide

PA VB 16 Technical manual

PA

PA VB 16 Technical manual

ADLINK Technology NuIPC cPCI-6760D Series manual

ADLINK Technology

ADLINK Technology NuIPC cPCI-6760D Series manual

ProSoft Technology PLX51-HART-4I quick start guide

ProSoft Technology

ProSoft Technology PLX51-HART-4I quick start guide

Texas Instruments TPA721 user guide

Texas Instruments

Texas Instruments TPA721 user guide

Samson 33-7 Mounting and operating instructions

Samson

Samson 33-7 Mounting and operating instructions

Digi XBee-PRO XSC manual

Digi

Digi XBee-PRO XSC manual

Newland NLS-EM2096 Integration guide

Newland

Newland NLS-EM2096 Integration guide

Nautel NxLink Technical instruction manual

Nautel

Nautel NxLink Technical instruction manual

Siemens SINAMICS G120 Compact operating instructions

Siemens

Siemens SINAMICS G120 Compact operating instructions

M-system EtherCAT R30GECT1 instruction manual

M-system

M-system EtherCAT R30GECT1 instruction manual

Dynojet Power Commander III USB EX installation instructions

Dynojet

Dynojet Power Commander III USB EX installation instructions

IOtech DBK41 user manual

IOtech

IOtech DBK41 user manual

Autel ATS100 user manual

Autel

Autel ATS100 user manual

Graco EM5 Series Instructions-parts list

Graco

Graco EM5 Series Instructions-parts list

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.