SICE ATRT0810 User manual

SICE LoRaWAN Gateway
Getting Started Guide
Models:
ATRT0810
ATRT0810-M

SICE LoRaWan Gateway ATRT0810/-M GETTING STARTED GUIDE
SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
2
Contents
Chapter 1 –SICE LoRaWAN Gateway .................................................................................................................... 4
Chapter 2 –Getting Started .................................................................................................................................. 5
Chapter 3 –Specifications and Related Information ........................................................................................... ..7
Chapter 4 –Safety Notices ................................................................................................................................. 10
Chapter 5 –Environmental Notices ..................................................................................................................... 13

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
3
CONTENTS
Chapter 1 –SICE LoRaWAN Gateway
The SICE LoRaWAN Gateway (ATRT0810/-M) is a LoRa IoT gateway device designed for outdoor deployments.
More information about the products and related datasheet on
https://www.sicetelecom.it/prodotto/iot/lorawan-gateway/

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
4
GETTING STARTED
Chapter 2 –Getting Started
Logging in to the device
After connecting and powering up your device, login to device:
1. Open an Internet browser. In the browser’s address field, enter the device's default address for the
device:
http://192.168.2.1
The login page appears.
2. Type the default user name: admin.
3. Type the default password: admin.
Setting the Password
Note: Note: For security reasons, we recommend you change the default password.
To set a new password:
1. Click Next on the Welcome panel.
2. In the Current Password field, enter the default password, admin.
3. In the New Password field, enter a new password.
4. Re-type the new password in the Confirm Password field.
5. Click Next.
Setting Date and Time
To set date and time:
1. Type today’s Date in the format shown or use the calendar (data picker).
2. Type the current Time (24-hour format).
3. Select the Time Zone in which the device operates.
4. Click Next.
Configuring PPP
Note: For models with cellular radios only (ATRT0810-M).
To configure the Cellular PPP:
1. To use PPP, check Enable. When enabled, your device functions as a cellular device.
2. If using two cellular antennas, check Diversity. Do not check this option if using one antenna.
3. To enable dial-on-demand, check Dial-on-Demand. This tells the device to only make a PPP connection
when there is outgoing IP traffic, and it brings the PPP connection down after a given idle timeout.
4. The default Idle timeout is 180 seconds. If desired, you can enter a different value.
5. Type the APN (Access Point Name). The APN is assigned by your wireless service provider.

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
5
GETTING STARTED
6. Click Next.
Setting Up PPP Authentication
To setup cellular PPP authentication:
1. Select an authentication protocol Type used to negotiate with the remote peer: pap, chap, or pap-chap.
The default is None.
2. Type the Username for the remote peer to use for authentication. Optional. Username is limited to 60
characters.
3. Type the Password for the remote peer to use for authentication. Optional. Password is limited to 60
characters.
4. Click Next to exit the wizard.
Enter IP Address and Network Information
Set the IP address and network information for the Ethernet port:
Note: Leave the interface static unless using a DHCP server on the network that the device is connecting to. If
you select DHCP client, you need to know which address is assigned to the device.
1. Type the device's IP Address
2. Enter the network Mask.
3. Enter the Gateway address (optional and not displayed when Cellular is enabled).
4. Enter the Primary DNS server address (optional and not displayed when Cellular is enabled).
5. Enter the Secondary DNS server address (optional and not displayed when Cellular is enabled).
6. Click Next.
Configuring Access
When Cellular is disabled, the default settings enable HTTPRedirect to HTTPs via LAN.
Note: Enabling HTTPs via WAN can increase security risk including allowing web users to access the WAN
interface.
1. Under HTTP Redirect to HTTPs, check Enabled to turn on or uncheck to turn off.
2. Enter Port or use default value.
3. Check either Via LAN or Via WAN.
4. Under HTTPs, enter Port or use default value.
5. Click Finish.
Finish Configuration
When you finish entering basic settings:
1. To save and apply the settings, click Save and Restart near the top of the left sidebar. The device restarts.
2. After restart, log back into the web interface. On the Dashboard under Cellular, the PPP state displays
Link is Up. You may have to wait for short time.

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
6
SPECIFICATIONS AND RELATED INFORMATION
Chapter 3 –Specifications and Related Information
SICE LoRaWan Gateway ATRT0810/-M Specifications
SICE LoRaWan Gateway ATRT0810/-M specifications depend on the hardware configuration for your model.
All Models
Category Description
General
SIM
Micro-SIM Holder (ATRT0810-M model)
Physical Description
Weight
4,4 kg
Dimensions
190mm x 280mm
Environment
Operating Temperature
-40° C to +70° C
Humidity
20%-90% RH, non-condensing
Power Requirements
Input Power
Power over Ethernet 802.3af
LoRa Specifications
The radio works @868MHz for the European region.
Category Description
General
Standards
LoRaWAN 1.0.2 specifications
Radio Frequency
868 MHz for Europe

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
7
SPECIFICATIONS AND RELATED INFORMATION
LTE Model (ATRT0810-M)
Category Description
General
Standards
LTE 3GPP Release 9
HSPA+ 21/GPRS fallback
Frequency Bands
4G
3G
2G
Speed
Data Speed
LTE: 100 Mbps downlink/50 Mbps uplink
HSPA+: 21 Mbps downlink/5.76 Mbps uplink
SMS
SMS
Point-to-Point messaging
Mobile-Terminated SMS
Mobile-Originated SMS

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
8
SPECIFICATIONS AND RELATED INFORMATION
LoRa Transmission Output Power
868 Models
Max output 25 dBm
Power Frequency On Power-up (dBm) 18 Hours After Bandwidth
Power-up (dBm)
27
869.525 MHz
24.18
25
125 kHz
27
869.525 MHz
24.18
24.83
250 kHz

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
9
SAFETY NOTICES
Chapter 4 –Safety Notices
EMC, Safety, and R&TTE Directive (RED) Compliance
The CE mark is affixed to this product to confirm compliance with the following European Community Directives:
Council Directive 2011/65/EU on the restriction of the use of certain hazardous substances in electrical
and electronic equipment;
and
Council Directive 2014/53/EU on radio equipment and telecommunications terminal equipment and the
mutual recognition of their conformity.
and
Council Directive 2014/35/EU on the harmonization of the laws of Member States relating to Electrical
Equipment designed for use within certain voltage limits.
SICE declares that this device is in compliance with the essential requirements and other relevant provisions of
Directive 2014/53/EU. The declaration of conformity may be requested, please write to [email protected]
Installation Safety
Warnings and Cautions
Warning and Caution symbols mean potential danger. You are in a situation that could cause bodily injury. Before
working on any equipment, be aware of hazards in the installation area and be knowledgeable about electrical
circuitry. Be familiar with standard practices for preventing accidents.
For translations of key cautions and warnings, refer Appendix A.
Warning: Only trained and qualified personnel should install, replace, or service this equipment. Installation
must comply with local and national electrical codes.
When installing or replacing the unit, the ground connection must always be made first and
disconnected last.
Disconnect POE power (Ethernet POE port) before servicing IP67 Base Station.
Do not work on the system or connect or disconnect cables during periods of lightning activity.
This device is not designed or approved to be used in any Hazardous Locations. Do not install or
operate device if area is known to be an explosive environment.
Externally ground this equipment using a customer-supplied ground wire before applying power.
Contact an electrician if you are uncertain that suitable grounding is available. Refer to Installing
the Ground Wire instructions. < All wall mounting installations are subject to the acceptance of
local jurisdiction.
Do not locate antenna near overhead power lines or other electric light or power circuits, or
where it can come into contact with such circuits. When installing the antenna, take extreme

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
10
SAFETY NOTICES
care not to come into contact with such circuits, because they may cause serious injury or death.
For proper installation and grounding of the antenna, please refer to national and local codes.
CAUTION:
Power over Ethernet (PoE) Certification does not apply or extend to voltages outside of standard
PoE range. Any PoE voltages beyond 0vdc to 60Vdc have not been evaluated by SICE. Nominal
PoE voltage is 48Vdc. The end user supplies the PoE cable. This cable must be suitable for
outdoor location. This is an 802.3at Type 2 device. Power input is 25W from standard 802.3at
PoE input.
Ethernet port is not designed to be connected to a public Telecommunication (PSTN) or any
other connection other than IEEE 802.3-2012 power over Ethernet devices.
Do not remove product labels.
Warning:
HOT SURFACE DO NOT TOUCH
Note: This symbol is included on the serial label. UL evaluated this device to a safety and outdoor
certification temperature of -30c to +85c.
Operating temperature is –40c to +70c.
User Responsibility
Respect all local regulations for operating your wireless device. Use the security features to block unauthorized use
and theft.

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
11
SAFETY NOTICES
Device Maintenance
When maintaining your device:
Do not attempt to disassemble the device. There are no user serviceable parts inside.
Do not misuse the device. Follow instructions on proper operation and only use as intended. Misuse could
make the device inoperable, damage the device and/or other equipment, or harm users.
Do not apply excessive pressure or place unnecessary weight on the device. This could result in damage to
the device or harm to users .
Do not use this device in explosive or hazardous environments unless the model is specifically approved for
such use. The device may cause sparks. Sparks in explosive areas could cause explosion or fire and may
result in property damage, severe injury, and/or death.
Do not expose your device to any extreme environment where the temperature or humidity is high. Such
exposure could result in damage to the device or fire.
Do not expose the device to water, rain, or spilled beverages. It is not waterproof. Exposure to liquids could
result in damage to the device.
Do not place the device alongside computer discs, credit or travel cards, or other magnetic media. The
information contained on discs or cards may be affected by the device.
Using accessories, such as antennas, that SICE has not authorized or that are not compliant with SICE's
accessory specifications may invalidate the warranty.
If the device is not working properly, contact SICE Technical Support via email: support@sicetelecom.it
Vehicle Safety
When using your device in a vehicle:
Do not use this device while driving.
Respect national regulations on the use of cellular devices in vehicles.
If incorrectly installed in a vehicle, operating the wireless device could interfere with the vehicle’s
electronics. To avoid such problems, use qualified personnel to install the device. The installer should verify
the vehicle electronics are protected from interference.
Using an alert device to operate a vehicle’s lights or horn is not permitted on public roads.

SICE LoRaWAN Gateway ATRT0810/-M | www.sicetelecom.it
12
ENVIRONMENTAL NOTICES
Chapter 5: –Environmental Notices
Waste Electrical and Electronic Equipment Statement
Note: This statement may be used in documentation for your final product applications.
WEEE Directive
The WEEE Directive places an obligation on EU-based manufacturers, distributors, retailers, and importers to take-
back electronics products at the end of their useful life. A sister directive, ROHS (Restriction of Hazardous
Substances) complements the WEEE Directive by banning the presence of specific hazardous substances in the
products at the design phase.
Instructions for Disposal of WEEE by Users in the European Union
The symbol shown below is on the product or on its packaging, which indicates that this product must not be
disposed of with other waste. Instead, it is the user's responsibility to dispose of their waste equipment by handing
it over to a designated collection point for the recycling of waste electrical and electronic equipment. The separate
collection and recycling of your waste equipment at the time of disposal will help to conserve natural resources
and ensure that it is recycled in a manner that protects human health and the environment. For more information
about where you can drop off your waste equipment for recycling, please contact your local city office, your
household waste disposal service or where you purchased the product.
Jan, 2018
This manual suits for next models
1
Table of contents
Popular Gateway manuals by other brands

Portech
Portech 372 Configuring and Installing

Interface Masters
Interface Masters TAHOE 8724 user guide

DEUTSCHMANN AUTOMATION
DEUTSCHMANN AUTOMATION UNIGATE CL ProfibusDP instruction manual

AudioCodes
AudioCodes MP-252 quick guide

MCK
MCK PBXgateway Quick installation guide

Proolin VoIP Tech
Proolin VoIP Tech FWT-8848 user manual