4.6.6 Humidity (RDG2..KN)................................................................. 60
4.6.7 Scheduler .................................................................................. 64
4.6.8 M/S, manager/subordinate (RDG2..KN) ..................................... 65
4.6.9 Preventive operation.................................................................. 69
4.6.10 NFC communication................................................................... 69
4.6.11 IAQ - CO2 monitoring and control (RDG2..KN)........................... 69
4.6.12 Power reserve clock (RDG2..T).................................................. 76
4.7 Control sequences.................................................................................... 77
4.7.1 Sequence overview (setting via P001)........................................ 77
4.7.2 Application mode ....................................................................... 78
4.7.3 2-pipe fan coil unit...................................................................... 80
4.7.4 2-pipe fan coil unit with electric heater........................................ 81
4.7.5 2-pipe fan coil unit with radiator or floor heating.......................... 83
4.7.6 2-stage on 2-pipe/4-pipe heating and cooling ............................. 85
4.7.7 4-pipe fan coil unit...................................................................... 90
4.7.8 4-pipe fan coil unit with electric heater........................................ 95
4.7.9 Chilled/heated ceiling and radiator applications .......................... 97
4.7.10 Compressor applications............................................................ 98
4.7.11 Applications with external AQR sensor or QMX room operator unit
(RDG2..KN) ............................................................................... 99
4.7.12 Setpoints and sequences........................................................... 99
4.8 Control outputs........................................................................................101
4.8.1 Overview...................................................................................101
4.8.2 Control output configuration for 6-port valve (P201)...................105
4.8.3 Control output configuration (setting via DIP switches 7/8 or tool,
and P201/P203/P204/P205)......................................................106
4.9 Fan control ..............................................................................................108
4.10 Multifunctional input, digital input..............................................................115
4.11 Handling system faults.............................................................................117
4.12 KNX communications (RDG2..KN)...........................................................118
4.12.1 S-Mode.....................................................................................118
4.12.2 M/S, Manager/subordinate configuration in KNX S-Mode ..........118
4.12.3 LTE-Mode.................................................................................121
4.12.4 Zone addressing in LTE-Mode (with Synco)..............................122
4.12.5 M/S, Manager/subordinate configuration in LTE-Mode ..............123
4.12.6 Example of heating and cooling demand zones.........................126
4.12.7 Send heartbeat and receive timeout..........................................126
4.12.8 Startup......................................................................................127
4.12.9 Heating and cooling demand.....................................................127
4.12.10 Fault and alarms function on KNX.............................................128
4.13 Communication objects (RDG2..KN)........................................................129
4.13.1 Overview...................................................................................129
4.13.2 Description of communication objects........................................131
4.14 Communication objects (LTE-Mode) (RDG2..KN).....................................137
4.15 Control parameters..................................................................................138
4.15.1 Parameter setting via local HMI.................................................138
4.15.2 Setting/downloading parameter via tool (RDG2..KN) .................139
4.15.3 Service level parameters...........................................................140