CONNECT AN EXPANSION UNIT (TR1310)
CONNECT THE AUXILIARY OUTPUT
It is possible to connect up to 10 expansion units to the
same device. (EXP function)
Second heating stage (15 sec / 15 min functions)
For more information, visit our Website:
660-0735-0022-E
CONNECT YOUR THERMOSTAT TO THE GT130 GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM DISCONNECT YOUR THERMOSTAT FROM THE GT130
GATEWAY OR A COMPATIBLE ZIGBEE SYSTEM
12
Connect all your
thermostats the same way,
by going to the next
closest thermostat.
34
GROUND FAULT PROTECTION
The thermostat is equipped with a ground fault protection that can detect a
current leakage of 5 mA. When a current leakage is detected, the ground fault
protection is triggered and quickly interrupts the power supply to prevent any
serious injuries.
Resetting the ground fault protection
The RESET button warning light turns ON (red) when the ground fault protection is
triggered. If the RESET button warning light turns ON during normal operation of
the thermostat, simply press the RESET button to reset the ground fault protection.
The light will turn OFF. If for any reason this situation occurs again, cut the power
to the heating system from the main electrical panel and ask a qualified
electrician to verify the installation.
Testing the ground fault protection
This thermostat has an Auto Test which
periodically verifies the correct operation of
the protection circuit. You can also do this
manually:
1) Press the TEST button. If the RESET button's
red warning light does not turn ON, the test
has failed. Cut the power to the heating
system from the main electrical panel and
ask a qualified electrician to verify the
installation.
2) Press the RESET button to restart the
thermostat's base.
TROUBLESHOOTING GUIDE
What should I do if the E1F code appears on my thermostat display?
The E1F code means that the thermostat is in “Floor” mode and there is no
connected sensor. If your thermostat is not intended to control a heated floor,
change the thermostat’s control mode for the “A mode”.
TECHNICAL SPECIFICATIONS
Operating voltage: 120/208/240 Vac, 50/60 Hz
Maximum load:
1800 W @ 120 V / 15 A
3120 W @ 208 V / 15 A
3600 W @ 240 V / 15 A
Setpoint range: 5 °C to 36 °C (41 °F to 97 °F)
Display range: 0 °C to 50 °C (32 °F to 99 °F)
Resolution: ±0.5 °C (±1 °F)
Storage: -20 °C to 50 °C (-4 °F to 122 °F)
Auxiliary output: 24 Vac / Vdc / 0.1 A
GFCI protection: Class A (5mA)
Protocol:
Zigbee 3.0
Frequency: 2.4 GHz
Transmission power: +20 dBm
Receiver sensitivity: -108 dBm
TR1310 TR1310
To others
TR1310
TH1300ZB
24 VCA
Baseboard
Convector
Transformer
Hub
2nd
1st
3rd
Transmitter Module IC : 22394-ZBM1501 / FCC ID:2AK2T-ZBM1501
This device complies with Industry Canada license exempt RSS standard(s). Operation is subject to
the following two conditions:
(1) this device does not cause interference, and (2) this device must accept any interference,
including interference that may cause undesired operation of the device.
This equipment has been tested and found to comply with the limits for a Class B digital device,
pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection
against harmful interference in a residential installation. This equipment generates, uses and can
radiate radio frequency energy, and if not installed and used in accordance with the instructions,
may cause harmful interference to radio communications. However, there is no guarantee that
interference will not occur in a particular installation. If this equipment does cause harmful
interference to radio or television reception, which can be determined by turning the equipment
OFF and ON, the user is encouraged to try to correct the interference by one or more of the
following measures:
Reorient or relocate the receiving antenna.
Increase the separation between the equipment and receiver.
Connect the equipment into an outlet on a circuit
different from that to which the receiver is connected.
Consult the dealer or an experienced radio/TV technician for help.
3-year limited warranty
SINOPE TECHNOLOGIES INC. warrants the components of their products against
defects in material and workmanship for a 3-year period from the date of purchase,
under normal use and service, when proof of purchase of such is provided to the
manufacturer. This warranty does not cover any transportation costs that may be
incurred by the consumer. Nor does it cover a product that has been improperly
installed, misused or accidentally damaged.
The obligation of SINOPÉ TECHNOLOGIES INC., under the terms of this warranty, will
be to supply a new unit and this releases the manufacturer from paying the
installation costs or other secondary charges linked to replacing the unit or the
components.
ADD YOUR THERMOSTAT TO THE GT130 GATEWAY
AND NEVIWEB
Tap the , then select "Add Device".
2
1If you do not have an account yet,
download the Neviweb app for iOS or
Android to create an account and add
your device.
Follow the steps of the Installation Wizard.
3
Initiate the connectivity session
by pressing the RF signal button
on the GT130 gateway. The
indicator light will start flashing.
Compatible Zigbee gateway:
refer to the installation guide for
the latter.
Connect your thermostat to the network
by pressing briefly and simultaneously
on the and buttons.
On the thermostat display:
Blinks: Connecting
Remains lit: Connected
If the connectivity fails, the
symbol will disappear from the
display. Refer to our Website to
troubleshoot the unit.
When all your devices are connected, close the
connectivity session of your GT130 gateway or
your compatible Zigbee gateway.
To disconnect your thermostat from the GT130 gateway or a
compatible Zigbee hub, press the and buttons
simultaneously for 10 seconds. The symbol will disappear
from the display.
10 sec.