Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Sloan Mobile Handwashing Station
MH-3050 Installation and Operation Instruction
Limited Warranty
Unless otherwise noted, Sloan Valve Company warrants its Mobile Handwashing Sink to be made of rst class materials, free from defects
of material or workmanship under normal use and to perform the service for which it is intended in a thoroughly reliable and efcient
manner when properly installed and serviced, for a period of one year from date of purchase. During this period, Sloan Valve Company
will, at its option, repair or replace any part or parts which prove to be thus defective if returned to Sloan Valve Company, at customer’s
cost, and this shall be the sole remedy available under this warranty. This warranty covers enclosure framing, panels, countertop material
and attachments. It does limit or extend individual product component warranties provided by the component manufacturer. No claims
will be allowed for labor, transportation or other incidental costs. This warranty extends only to persons or organizations who purchase
Sloan Valve Company’s products directly from Sloan Valve Company for purpose of resale. This warranty does not cover the life of the
batteries.
THERE ARE NO WARRANTIES WHICH EXTEND BEYOND THE DESCRIPTION ON THE FACE HEREOF. IN NO EVENT IS SLOAN VALVE COMPANY
RESPONSIBLE FOR ANY CONSEQUENTIAL DAMAGES OF ANY MEASURE WHATSOEVER.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 2 of 11
Installation Instructions
Code #: 0816885 Draft: 7.0 (10/20)
Parts List
Description Item Number Quantity
Panel, Lower Front 1 1
Panel, Left 2 1
1/4” Hex Key (Not Shown) 3 1
Paper Towel Key (Tool) (Not Shown) 4 1
Trash Bag Holder (Not Shown)
For standard 13 gallon draw-string trash bag, see spare parts list for details. 5 1
Figure 1
1) Panel, Lower Front
2) Panel, Left
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 3 of 11
Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Component / Description
Component Description
Soap Dispenser GoJo ES-8
Paper Towel Dispenser EnMotion Impulse Auto Paper Towel Dispenser, White
Faucet Sloan EFX Series Faucet
Access Panel - Right Hinged
Access Panel - Front Removable
Access Panel - Left Removable
Forklift Guides Guides for forklift
Waste Tank 16 Gallon Waste Tank
Pull Handle Handle for moving unit around facility
AC Power In 3 Prong Twist Lock
Water Supply In 3/4” garden hose connection
Waste Water Out 3/4” garden hose connection
AC / DC On/Off 3 way toggle switch, center off
Main Power Switch On/Off Main power switch to the Rapid Response Wash Station
Drain Pump Switch On/Off Supplies power to the drain pump
MH-3050 Mbl Hand Hyg 1 St SS w Heat Tank Component Layout
Figure 2
Fork Lift Guides
Panel, Left
(Removable)
Pull Handle
Waste Tank
Paper Towel Dispenser
Soap Dispenser
Faucet
Panel, Right
(Hinged)
Front View
Note: Front panel not shown for clarity.
A
A
Water Supply In
Waste Water Out
(Gravity Fed)
Rear View
AC Power In
Waste Water Out
(Pump)
Drain Pump
On/Off
Water Heater
On/Off
A-A
Right Side View
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 4 of 11
Installation Instructions
Code #: 0816885 Draft: 7.0 (10/20)
Initial Setup Prior to First Use
IMPORTANT
(Must be completed before initial power up and water connection)
• Use holding tank cleaner/treatment for 16 gallon waste tank.
• Sanitation of the fresh water pump (if applicable) must be completed prior to initial use.
• Batteries for the paper towel dispenser are shipped loose and must be installed prior to initial use.
• Soap bottle is shipped loose and must be installed prior to initial use.
This mobile handwashing sink has multiple options for power, water supply, and drainage. See below.
Power
• AC Power
–Select this option when power can be supplied by an external source.
• DC Power (If applicable)
–Select this option when external power is not available, and battery power is required.
Water Supply
• External Water Supply
–Select this option when external water connection is available, this option can be connected via a 3/4”
garden hose.
• 5 Gallon Water Supply (If applicable)
–Select this option when external water connection is not available, two 5 gallon water bottles (not supplied)
are required.
Drainage
• Manual (Gravity fed)
–Select this option if no power is available to the unit. This option is controlled by a ball valve.
• Electric Pump
–Select this option select this option if AC or DC power has been select, this option is controlled by a switch.
–Select this option if waste needs to be pumped up hill or over a long distance.
Faucet:
• Refer to detailed EFX-150 instructions available via Sloan.com for the following:
–Sensor calibration (If required)
Note: Failure to properly calibrate the faucet sensor may lead to unexpected activation and increase
maintenance intervals.
–Priming
–Battery battery replacement
–Care and cleaning
Soap Dispenser:
• Refer to detailed CS-8 instructions available via GOJO.com for the following:
–Installation of replacement soap bottle and battery (Shipped together)
–Care and cleaning
Paper Towel Dispenser:
• Refer to EnMotion manufacturer instructions for the following:
–Installation of batteries (Included, shipped loose)
–Paper towel installation
–Paper length setting
–Care and cleaning
Fresh Water Pump:
• Refer to detailed instructions available via Xylem.com for the following:
–Sanitize unit prior to rst use.
–Routine sanitation must occur as required, minimum 6 times per year.
16 Gallon Waste Tank
• Sanitation of Grey Water Tank
–The 16 Gallon grey water tank must be treated to break down waste and eliminate odors. Using a liquid
holding tank cleaner/treatment, follow the holding tank cleaner instructions for cleaning or treatment of grey
water holding tank. For best results, clean and ush the tank weekly regardless of the water level or usage.
Recommend using a formaldehyde-free formulation that is safe for all pipes including PVC. Routine treatment
is an important step to ensure reliable service.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 5 of 11
Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Setting Up for External Water Supply In and Waste Water Out
Figure 3
Water Supply in
Waste Water Out
(Gravity Fed)
Waste Water Out
(Pump)
1. Connect to water supply in.
a. Make sure that the external water is OFF
b. Using a standard 3/4” yard hose or equivalent, connect to an external water supply.
c. Connect the opposite end of the hose to the Water Supply In on the middle, rear panel of the Rapid
Response Wash Station.
d. Make sure that connection is tight and does not leak.
2. Connect to waste line out (Gravity Fed).
a. Using a standard 3/4” yard hose or equivalent, connect to the Waste Line Out on the bottom, rear
panel of the Rapid Response Wash Station.
b. Make sure that connection is tight and does not leak.
c. Place the opposite end of the hose in an appropriate area for draining waste water tank.
3. Connect to waste line out (Pump).
a. Make sure that the gravity fed ball valve is in the closed position.
b. Using a standard 3/4” yard hose or equivalent, connect to the Waste Line Out on the bottom, rear
panel of the Rapid Response Wash Station.
c. Make sure that connection is tight and does not leak.
d. Place the opposite end of the hose in an appropriate area for draining waste water tank.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 6 of 11
Installation Instructions
Code #: 0816885 Draft: 7.0 (10/20)
Connect the AC Power In
Figure 4
AC Power In
WARNING - Risk of Electric Shock. Connect Only to a Supply Protected by a Ground-Fault Circuit-Interrupter (GFCI).
1. Plug a 12/3-Prong NEMA L5-20 AMP 125V Power cord (Not supplied) into twist lock AC Power In receptacle
on the rear panel of the Mobile Handwashing Sink, and connect the opposite end to a matching NEMA L5-
20R twist-lock receptacle (120V/20A).
Note:
Strain Relief - UL 1951, Clause 10.4 and C22.2 No. 68, Clause 5.6 - A exible cord shall be provided with a means
to reduce the transmittal of tensional or rotational force from the cord to the wiring connections. A detachable
exible power supply cord will be permitted for the 120 VAC powered Hand Washing Stations if the appliance
inlet is a twist-lock design.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 7 of 11
Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Operation Instructions AC Power
Figure 5
Fork Lift Guides
Panel, Left
(Removable)
Pull Handle
Waste Tank
Paper Towel Dispenser
Soap Dispenser
Faucet
Panel, Right
(Hinged)
Front View
Note: Front panel not shown for clarity.
A
A
Water Heater
Drain Pump
On/Off
Water Heater
On/Off
A-A
Right Side View
1. Position the Mobile Handwashing Sink where needed.
2. Lock each caster in place to secure the Mobile Handwashing Sink in place.
a. Press down on the lock lever for each caster until the lever locks into place and the caster no longer
rotates freely.
b. To release the lock lever, press up on each lock lever until the lever locks in the open position and the
caster rotates freely.
3. Connect external water supply in and the waste line out.
4. Plug a 12/3-Prong NEMA L5-20 AMP 125V Power cord (Not supplied) into twist lock AC Power In receptacle
on the rear panel of the Mobile Handwashing Sink, and connect the opposite end to an 110 VAC power
source.
5. Using AC Power.
a. Position the AC / DC Switch to the AC position.
b. Position the Main On/Off Switch in the on position.
c. If using the electric drain pump option, position the drain pump switch in the On position.
6. When using the Mobile Handwashing Sink for the rst time, prime the sensor faucet by moving your hand in
front of the faucet sensor to prime the water lines.
The Mobile Handwashing Sink is ready for use.
7. Drain Waste Tank when above half full.
a. Periodically remove or open an access panel to check the waste tank water level. If the waste tank
water level is more than half full, drain the waste tank.
8. Set all switches to the off position when not in use
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 8 of 11
Installation Instructions
Code #: 0816885 Draft: 7.0 (10/20)
Draining the Waste Water Tank (Gravity Fed)
Figure 6
DETAIL A
Waste Line Ball Valve
(Open Position)
Waste Line Ball Valve
(Closed Position)
SEE DETAIL A Note: Water heater not shown for clarity.
1. Drain the waste tank (Gravity Fed).
a. Make sure that waste line hose is connected to waste line out (Gravity Fed Location, Figure 3. page
5) at the bottom rear panel of the Rapid Response Wash Station.
b. Make sure that the opposite end of the waste line hose is in an appropriate location to drain the waste
water tank. 16 gallons minimum drainage.
c. Open the right side access panel.
d. Locate the waste line ball valve and turn a 1/4 turn to open the valve.
e. Close the waste line ball valve when waste water tank is empty.
f. Close and latch the right access panel.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 9 of 11
Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Draining the Waste Water Tank (Electric Pump)
Figure 7
Waste Pump
On/Off
Detail B
SEE DETAIL B
Right Side
1. Drain the waste tank (Electric Pump).
a. Make sure that waste line hose is connected to waste line out (Pump Location, Figure 3. page 5) at
the bottom rear panel of the Mobile Handwashing Sink.
b. Make sure that the opposite end of the waste line hose is in an appropriate location to drain the waste
water tank. 16 gallons minimum drainage.
c. Use the 1/4” Hex Key (Included). unlock the cam latch on the right access panel. Open the right side
access panel.
d. Locate the Main On / Off Switch and toggle to the On position.
e. Locate the Waste Pump On Off Switch and toggle to the On position.
f. Toggle Waste Pump Switch to the Off position when the waste tank is empty.
Note: Failure to turn the waste water pump off when the tank is empty can damage the pump or cause
premature pump failure.
g. Close and latch the right access panel.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 10 of 11
Installation Instructions
Code #: 0816885 Draft: 7.0 (10/20)
Notes:
1. Frequency may vary per actual daily use.
2. Recharge battery daily, regardless of use. Make sure that battery is fully charged prior to each use.
3. Empty and treat waste water tank weekly, regardless of use.
Suggested Usage Schedule
Description Unit of Measure Frequency
Fresh Water 5gal Bottle 3 per Day
Waste Water 16 gal Tank Drain Daily
Battery Charge Full Charge Weekly
Soap Rell Rell 2 per Day
Paper Towel Rell Roll Daily
Additional guidance for surface care and maintenance can be found at:
https://www.corian.com/IMG/pdf/k-29810_corian_solid_surface_care_and_maintenance_for_facility_
managers.pdf
Stainless Steel Care
Stainless steel has a bright surface that is easy to clean and is free from oxides. Therefore, cleaning of stainless
steel is relatively simple and easy if done on a regular basis.
Frequency of cleaning should depend on the rate at which the xture becomes dirty. Remember that fresh
(soft) deposits of all kinds are relatively easy to remove, while removing older are much more difcult. Establish
a cleaning SCHEDULE. Routine cleaning should involve ordinary soap or detergent and water, applied with a
sponge, brush or cloth. Rinse THOROUGHLY and wipe dry.
DO NOT use common steel wool, scouring pads, scrapers, wire brushes, les or other steel tools to clean stainless
steel. Certain chemical compounds, if used on stainless steel can give the appearance of rust and if allowed
to stand for long periods of time can pit the surface of stainless steel. Products containing hydrochloric acid,
muriatic acid or potassium hydrochloride should never be used.
Tips to Keep Stainless Steel Clean and Corrosion Free
1. Utilize the proper tools.
2. Wipe with the grain of the stainless steel.
3. Utilize alkaline, alkaline chlorinated, or non-chloride containing cleansers.
4. Soften hard water with lters to reduce mineral deposits.
5. Clean your equipment frequently to prevent food particles from causing pits and cracks.
6. If a chlorinated cleanser is used, rinse and dry immediately.
7. Absolutely, never under any circumstances use hydrochloric acid (muriatic acid) on stainless steel.
8. Periodically restore or passivate your stainless steel.
Lubrication
Periodically apply silicone or oil lubricant to moving parts such as casters and hinges for smooth operation and
protection.
Care and Maintenance
DuPont Corian®Surface Care
Most Dirt & Residue
Use soapy water or ammonia-based cleaner (not window cleaner), rinse
and wipe completely dry. Commercially available solid surface cleaners
such as Clean EnCounters® also works well.
Preventing Hard Water Marks Rinse and wipe completely dry after cleaning. Clean spills before they dry.
Removing Hard Water Marks Use cleaner formulated for removing hard water such as CLR® or Lime-A-
Way®
Disinfecting
Occasionally wipe surface with diluted household bleach – 1:100 (5 Tbsp.
of bleach to 1 gallon of water, as recommended by the CDC for disinfec-
tion of surfaces.
10500 Seymour Ave Franklin Park, IL 60131 | Phone: +1.847.671.4300 / +1.800.982.5839 | Fax: +1.800.447.8329 | Sloan.com
Copyright © 2020 Sloan. All rights reserved.
Page: 11 of 11
Installation Instructions
Code #: 0816884 Draft: 7.0 (10/20)
Spare Parts List
Item No. Code No. Description
1A 3324026 Sloan® BASYS® EXF-150 Sensor Faucet
2A 0383300 PURELL® CS8 Soap Dispenser
2B 0383301 PURELL® CS8 1200 mL HEALTHY SOAP® rell, 2pk.
3 0383332 Georgia Pacic® enMotion® Impulse® Automatic Paper Towel Dispenser, White
4 0383505 Pull Handle
5 0383390 Trash bag Holder
6 0383518 Graphic Label Kit
7 0386057 McGuire® ProDrain® with 1 1/4" Tailpiece
8 0383323 Rain Hood
9 0383333 Eemax® MiniTank™ EMT1 1.5 Gallon Electric Water Heater
10 3830010 MH PANEL ASM-UPPER FRONT NO DISPLAY
11 3830008 MH PANEL ASM-LOWER FRONT
12 3830006 MH PANEL ASM-LEFT
13 3830007 MH PANEL ASM-RIGHT
12A, 2B
3A
4
5
78
6
9
10
11 12 13
Illustrated Parts List

Other Sloan Bathroom Fixture manuals

Sloan TruFlush TRF 156-1.6 User manual

Sloan

Sloan TruFlush TRF 156-1.6 User manual

Sloan Optima EBF-750-S Use and care manual

Sloan

Sloan Optima EBF-750-S Use and care manual

Sloan Solis EAF-275 Series User manual

Sloan

Sloan Solis EAF-275 Series User manual

Sloan TruFlush TRF 156-1.28 User manual

Sloan

Sloan TruFlush TRF 156-1.28 User manual

Sloan Optima EBF-85 Use and care manual

Sloan

Sloan Optima EBF-85 Use and care manual

Sloan Optima EBF-650 Use and care manual

Sloan

Sloan Optima EBF-650 Use and care manual

Sloan OPTIMA I.Q. EAF-150 Series User manual

Sloan

Sloan OPTIMA I.Q. EAF-150 Series User manual

Sloan TRUFLUSH Series User manual

Sloan

Sloan TRUFLUSH Series User manual

Sloan BASYS EFX-8 User manual

Sloan

Sloan BASYS EFX-8 User manual

Sloan OPTIMA I.Q. EAF-100-ISM Use and care manual

Sloan

Sloan OPTIMA I.Q. EAF-100-ISM Use and care manual

Sloan EBF-825 User manual

Sloan

Sloan EBF-825 User manual

Sloan MH-1000 User manual

Sloan

Sloan MH-1000 User manual

Sloan Optima EBF-415 User manual

Sloan

Sloan Optima EBF-415 User manual

Sloan OPTIMA plus EAF 350 Series User manual

Sloan

Sloan OPTIMA plus EAF 350 Series User manual

Popular Bathroom Fixture manuals by other brands

Kohler Mira Sport Max J03G Installation and user guide

Kohler

Kohler Mira Sport Max J03G Installation and user guide

Moen 186117 Series installation guide

Moen

Moen 186117 Series installation guide

Hans Grohe Raindance Showerpipe 27235000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe Raindance Showerpipe 27235000 Instructions for use/assembly instructions

Signature Hardware ROUND SWIVEL BODY SPRAY 948942 Install

Signature Hardware

Signature Hardware ROUND SWIVEL BODY SPRAY 948942 Install

fine fixtures AC3TH installation manual

fine fixtures

fine fixtures AC3TH installation manual

LIXIL HP50 Series quick start guide

LIXIL

LIXIL HP50 Series quick start guide

KOLO ATOL PLUS installation manual

KOLO

KOLO ATOL PLUS installation manual

Hans Grohe PuraVida 15073000 Instructions for use/assembly instructions

Hans Grohe

Hans Grohe PuraVida 15073000 Instructions for use/assembly instructions

Toto TS111B8 Installation and owner's manual

Toto

Toto TS111B8 Installation and owner's manual

Kohler K-1158-H2 Homeowner's guide

Kohler

Kohler K-1158-H2 Homeowner's guide

Coram Showers OFFSET QUADRANT manual

Coram Showers

Coram Showers OFFSET QUADRANT manual

baliv DU-2010 manual

baliv

baliv DU-2010 manual

odass OD-1710 instruction manual

odass

odass OD-1710 instruction manual

Oxygenics Evolution Easy installation instructions

Oxygenics

Oxygenics Evolution Easy installation instructions

Bradley Express SS Series installation instructions

Bradley

Bradley Express SS Series installation instructions

Helvex TH-974 installation guide

Helvex

Helvex TH-974 installation guide

DURAVIT C.1 C15240 0090 Instructions for mounting and use

DURAVIT

DURAVIT C.1 C15240 0090 Instructions for mounting and use

Sunshower PURE SOLO manual

Sunshower

Sunshower PURE SOLO manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.