TL-2100SER1 Safety Auto-Reset™ Fall/Mobility Monitor
Seat Belt
SEAT BELT PLACEMENT
• Unscrew the one screw on either side of the wheelchair that holds the seat
in place.
• Attach the seat belt to the wheelchair by lining up the grommet holes on
the seat belt with the screw hole and re-insert screws through both the
seat belt and the wheelchair to hold the seat belt in place. Make sure the
screws are tightened.
• Adjust the seat belt to the desired length using the black buckle that holds
the adjustment strap in place.
• Place the monitor out of the reach of the resident. The suitable mounting
location is the back of the wheelchair, so that the resident cannot tamper
with the monitor.
TEST THE SYSTEM
• Buckle and unbuckle the seat belt to set o the alert. The monitor is now
active. The alert will sound whenever the seat belt is unbuckled.
• When the system is activated, press the “Reset” button on front of the
monitor to silence the alert.
Bed Sensor Pads
BED PLACEMENT.
• Place the pad under the resident’s shoulders to be
alerted when the resident sits up in the bed.
• Place the pad under the resident’s lower back/buttocks to
be alerted when the resident vacates the bed.
• Place the monitor out of reach of the resident. Suitable
mounting locations include: the back of headboard, the wall
or under the bed. Make sure the resident cannot tamper with
the monitor.
TEST THE SYSTEM
• Plug the pad into the monitor and apply pressure
to the pad to activate the system. The monitor will beep
twice when active.
• The alert will sound when pressure is released
from the pad. Press the “Reset” button on the front of the
monitor to silence the alert.
Chair Sensor Pads
WHEELCHAIR/CHAIR PLACEMENT
• Center the pad on the chair seat.
• Place the monitor out of reach of the resident. Suitable mounting locations
include: the back or handle of the wheelchair. Make sure the resident
cannot tamper with the monitor.
TEST THE SYSTEM
• Plug the pad into the monitor and apply pressure to the pad to activate
the system. The monitor will beep twice when active.
• The alert will sound when pressure is released from the pad.
Press the “Reset” button on front of the monitor to silence the alert.
Floor Mats
FLOOR MAT PLACEMENT
• Place the Floor Mat in the desired location such as a critical doorway or
next to a bed.
• Place the monitor out of the reach of the resident.
TEST THE SYSTEM
• Step on the Floor Mat to set o the alert. The monitor is now active.
The system will sound any time weight is on the Floor Mat.
• When the system is activated, press the “Reset” button on front of the
monitor to silence the alert.
SMART CAREGIVER CORPORATION
1229 North McDowell Blvd., Petaluma, CA. 94954 | Tel: 800-650-3637
sales@smartcaregivercorp.com | www.smartcaregivercorp.com
Need Set-up Help? (800) 650-3637
Change Pad Indicator
Reset
Status
Check Pad
Low Battery
Pad & Monitor
Active when Blinking
Bed Pad
Change Pad Indicator™
Reset
Status
Check Pad
Low Battery
Pad & Monitor
Active when Blinking
Bed Pad
Change Pad Indicator™
Reset
Status
Check Pad
Low Battery
Pad & Monitor
Active when Blinking
Change Pad Indicator
Reset
Status
Check Pad
Low Battery
Pad & Monitor
Active when Blinking
Change Pad Indicator
Reset
Status
Check Pad
Low Battery
Pad & Monitor
Active when Blinking
Floor Mat
Change Pad Indicator
Reset
Status
Pad Lost
Low Battery
Pad & Monitor
Active when Blinking
Floor Mat
Change Pad Indicator
Reset
Status
Pad Lost
Low Battery
Pad & Monitor
Active when Blinking
CAUTION: If using this monitor with the Change Pad Indicator™ Timed Sensor Pads, this monitor will not indicate when pad life has expired. The
pads will still function normally. Call (800) 650-3637 for more information.
WARNING: Failure to comply with the warning may result in injury or death. This device is not suitable for all individuals. Other devices may be
required. This device is not a substitute for visual monitoring by a caregiver. The manufacturer does not claim that this device will stop elopement
and/or stop falls. This device is designed to augment caregivers’ comprehensive resident mobility management program. Test this device before each
use. Read the instructions and Legal Disclaimer.
The Smart Caregiver Corporation TL-2100SER1 Monitor is designed to be installed by the end user. As such, it is the entire responsibility of the
buyer to insure that the system is properly installed and tested. Further, the system is not designed to replace good caregiving practices including,
but not limited to:
A.) Direct patient supervision
B.) Adequate training for sta personnel for fall prevention and elopement
C.) Testing of the system before each use
WHERE PERMISSIBLE, IT IS THE SELLER’S INTENT TO LIMIT ANY LIABILITY FOR SPECIAL, CONSEQUENTIAL OR INCIDENTAL ECONOMIC DAMAGES TO
REFUND OF THE PURCHASE PRICE OR REPLACEMENT OF THE GOODS. SELLER DISCLAIMS ANY LIABILITY FOR COMPENSATORY OR OTHER DAMAGES
ARISING OUT OF THE USE OF THE GOODS.
WARNING: The manufacturer does not claim that this device will stop elopement and/or stop falls. This device is designed to augment caregivers’
comprehensive resident mobility management program. This product is to be used by a licensed caregiver only.
Limited Warranty: Seller warrants that the goods sold will be free from defects of workmanship and manufacturing, for a period of one year from
the date of sale. Other than this limited warranty, seller makes no express or implied warranties. Except for this limited warranty, NO EXPRESS OR
IMPLIED WARRANTIES ARE GIVEN AND NO AFFIRMATION OF SELLER, BY WORDS OR ACTION, WILL CONSTITUTE A WARRANTY. THE GOODS BEING
PURCHASED ARE BEING SOLD ON A “WITH ALL FAULTS” BASIS. THE ENTIRE RISK AS TO THE QUALITY AND PERFORMANCE OF THE GOODS IS WITH THE
BUYER. SHOULD THE GOODS PROVE DEFECTIVE FOLLOWING THEIR PURCHASE, THE BUYER, AND NOT THE MANUFACTURER, DISTRIBUTOR OR RETAILER,
ASSUMES THE ENTIRE COST OF ALL NECESSARY INSTALLATION, SERVICING OR REPAIRS.
21
Installation and Use Instructions
PATENT PENDING
TL-2100S
Safety Auto-Reset™
Fall Monitor
SMART CAREGIVER CORPORATION
• Pad Lost (Patent Pending) light alerts
caregivers when a pad is disconnected
PATENTED TECHNOLOGY
with included Caregiver KeyTM
Install Battery, Adjust Settings
1 2 3
5
4
Mounting the TL-2100S
Mounting screw
in headboard
or wall.
The monitor may mounted to a bed or a chair with the included locking mounting strap.
Hang the monitor
on the screw using
the mounting hole
on back of the
monitor.
1 2
Safety Auto-Reset™
Reset
Status
Pad LostLow Battery
Pad & Monitor
Active when Blinking
Bed Pad
Bed Pad
Test the system. (A) Put pressure on the sensor pad to activate the pad and
the fall monitor. The fall monitor will beep two times to indicate that the
sensor pad and the fall monitor are in use. The “Status” light will blink when
pressure is on the pad. (B) When pressure is removed, the fall monitor will
sound the alert tone. Press the reset button to silence the alert .
Test the System - Pressure Pads
A.
B.
Reset
Button
Connect the Pressure Pad
A.
B.
To Set Alarm position the
switches as desired using
chart shown above. Use a
pen point to move switches.
Delay
2 Sec.
1 Sec.
0 Sec.
Melody
3
2
1
Volume
Decrease Increase
/
Insert battery as shown.
The black ribbon should be under
the battery for easy removal.
TL-2100S settings: Volume, Tone
and Alert Delay.
Close the battery door and secure
it with the small Phillips-head
screw.
Place the TL-2100S in its
protective plastic boot.
Quick Start Instructions TL-2100S
Need Set-up Help? (800) 650-3637
SMART CAREGIVER CORPORATION
Tel: 800-650-3637 | www.smartcaregivercorp.com
FLOOR MAT
Safety Auto-Reset™
Reset
Status
Pad LostLow Battery
Pad & Monitor
Active when Blinking
TL-2100SER1
Refer to instructions
before changing this setting
Bottom of monitor
Test the System -
Floor Mats Reset
Button
Step on the oor mat.
The alert will sound. Press the Reset button to silence and reset the monitor.
Pinch the cord together
and route it through the
strain relief recess.
Plug the cord
into the monitor.
Alert Delay Adjustment
Default Setting: 0 Seconds
Alert Tone/Melody Adjustment
Default Setting: Tone 1
Volume Adjustment
Default Setting: Full Volume
Reset
Status
Pad
Lost
Low
Battery
Safety Auto-Reset™
Pad & Monitor
Active when Blinking
Resetting the Monitor/Tamper Proof ™ Mode with Caregiver Key™ (Optional)
Caregivers can choose to reset the
TL-2100S in either of two ways:
1. Pressing the Reset/Status button on
the front of the monitor (“Reset Button
ON” mode).
2. Placing the optional Caregiver Key™
over the red dot on the front of the
monitor. (“Caregiver Key™ ON” mode).
This mode allows only the caregiver to
reset the monitor.
Select either “Reset Button ON” or
“Caregiver Key™ ON” with the switch on
the side of the TL-2100S Fall Monitor.
“Reset Button ON” Mode
Press the Reset/Status button to
reset the monitor.
“Caregiver Key™ ON” Mode
Place the Caregiver Key™ over the red dot to reset the monitor.
For more information about the
Caregiver Key™ and how it can be used in
your facility’s Fall Assessment Program
call 800-650-3637
Reset
Status
Pad
Lost
Low
Battery
Safety Auto-Reset™
Pad & Monitor
Active when Blinking

This manual suits for next models

1

Other SMART Medical Equipment manuals

SMART S20A User manual

SMART

SMART S20A User manual

SMART TL-2020 Product manual

SMART

SMART TL-2020 Product manual

SMART ICE S30B User manual

SMART

SMART ICE S30B User manual

Popular Medical Equipment manuals by other brands

Culligan Aqua-Cleer MFP 4-44-MD 400 User's & technical manual

Culligan

Culligan Aqua-Cleer MFP 4-44-MD 400 User's & technical manual

FIOR & GENTZ NEURO HiTRONIC Instructions for Use for Patients

FIOR & GENTZ

FIOR & GENTZ NEURO HiTRONIC Instructions for Use for Patients

AtriCure cryoICE BOX1 user manual

AtriCure

AtriCure cryoICE BOX1 user manual

Sper scientific 840034 instruction manual

Sper scientific

Sper scientific 840034 instruction manual

iReliev iRecover et-1313 instruction manual

iReliev

iReliev iRecover et-1313 instruction manual

Mettler Electronics TENS 212 instruction manual

Mettler Electronics

Mettler Electronics TENS 212 instruction manual

iCR iCR 3600 Service manual

iCR

iCR iCR 3600 Service manual

ulrich medical ADDplus anterior distraction device plus Instructions for use

ulrich medical

ulrich medical ADDplus anterior distraction device plus Instructions for use

Moretti LOGIKO VISUAL DM325 instruction manual

Moretti

Moretti LOGIKO VISUAL DM325 instruction manual

Whitehall Thermalator T-12-M Instructions for operation and care

Whitehall

Whitehall Thermalator T-12-M Instructions for operation and care

Dräger HP Instructions for use

Dräger

Dräger HP Instructions for use

3B Medical RESmart BPAP Quick reference sheet

3B Medical

3B Medical RESmart BPAP Quick reference sheet

Synthes TRS Automated Cleaning Instructions

Synthes

Synthes TRS Automated Cleaning Instructions

Hologic Omni 4K Quick setup guide

Hologic

Hologic Omni 4K Quick setup guide

globex Standard Evacuation Chair manual

globex

globex Standard Evacuation Chair manual

Enraf Nonius Curapuls 670 Service manual

Enraf Nonius

Enraf Nonius Curapuls 670 Service manual

Otto Bock 502 manual

Otto Bock

Otto Bock 502 manual

Breas Clearway 2 Service manual

Breas

Breas Clearway 2 Service manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.