BOX M GSM DOMO / DOMO+
innovative in electronics
INSTRUCTION MANUAL
DESCRIPTION
C
GSM RECEIVER
The SMINN GSM receivers are designed with next generation
electronic components. They support up to 35 users.
User addition is easy and simple whether it is done via GSM
or via the receiver's push button.
They allow activation and deactivation of home automation
and control devices like:
Heating, Air conditioning
Irrigation
Alarms, security and surveillance systems
Pools, spas and tanks
Blinds, awnings, doors and access
Each device is built with high quality components and materials
and the latest technology, complying with current regulations
for use in residential, commercial and light industry installations.
ERROR
SIM card not inserted.
Modem does not respond
No MASTER
PASWORD 0000
Memory error
Led RUN
ON
OFF
ON
Slow blinking
Fast blinking
Led GSM ON
OFF
ON
ON
ON
ON
BUZZ
OFF
OFF
Beep when booting up
Beep when booting up
Beep when booting up
OPERATION
When a call or SMS is received from a registered number, as long as it is not blocked, it will
activate the corresponding relay. It can operate in three modes:
-IMPULSIVE: on the K4 relay with a missed call.
-IMPULSIVE / BISTABLE: on K1, K2, K3 or K4 relays via SMS.
-CONFIGURATION: also via SMS.
USER STORAGE
Each device allows storing up to 35 phone numbers as described:
-MANUALLY: Calling from the phone number you want to register while you hold the PROG
button(see Fig. 2-5).
-SMS: Sending an SMS with a specific format from the Manager/MASTER phone. The first
number to be manually stored will be the system manager.
The manager can send SMS to REGISTER, UNREGISTER, BLOCK, UNBLOCK and REPLACE
users’ numbers, as well as send configuration messages.
IMPULSIVE OPERATION MODE
When receiving a call from a registered phone which is not blocked, the receiver activates the
K4 relay for 1 sec. and hangs up the call.
This mode is useful for garage gates, electronic locks, etc.
SMS OPERATION MODE
When receiving an SMS with a specific format from a non blocked registered phone in the
memory the receiver does the requested operation and gives a missed call.
The receiver understands the following commands:
Requesting state.
With the order #STATUS#, the system sends an SMS where it tells the state of all relays
(and inputs for the DOMO +).
Relay bistable activation (stays activated until a switch off order)
#RELAY_n#ON#B# - Activate relay 'n' in bistable mode.
#RELAY_n#ON#0# - Activate relay 'n' in bistable mode.
Relay impulsive activation (stays activated the number of seconds indicated by ‘y’,
between 1 and 99 sec).
#RELAY_n#ON#y# - Activate relay 'n' for ‘y’ seconds.
Relay deactivation.
#RELAY_n#OFF# - Deactivate relay 'n'.
Note: replace ‘n’ by the relay number you want to activate/deactivate.
For instance: #RELAY_2#ON#10# : Activate relay 2 for 10 seconds.
CONFIGURATION
Sending configuration messages from Manager/MASTER’s phone it is possible to:
-Customize RELAY_n and INP_n names
-Register and unregister users
-Block and unblock users
-Modify the password
The default system password is 0000.
The receiver will send an SMS with the result of the configuration order.
Considering 0000 the system password and XXXXXXXXX the phone number, we can carry out
the following orders:
Register a user: #0000#NEWU#XXXXXXXXX#
If we send an already registered user that is blocked, this order will unblock it.
Replace a user: #0000#REPL#XXXXXXXXX#YYYYYYYYY#
Where XXXXXXXXX is the phone number to be replaced.
Where YYYYYYYYY is the new phone number.
Unregister a user: #0000#DELU#XXXXXXXXX# (Only in HOME version)
Block a user: #0000#BLCK#XXXXXXXXX#
Unblock a user: #0000#UBCK#XXXXXXXXX#
Password modification: #0000#MODP#1234#
Where ‘0000’ is the current password of the installation and ‘1234’ the new one.
Change manager: #0000#NEWM#XXXXXXXXX#YYYYYYYYY#
Where ‘XXXXXXXXX’ is the manager/MASTER’s current phone number.
Where ‘YYYYYYYYY’ is the manager/MASTER’s new phone number.
In this case, to keep the installation working given the case the current MASTER has been
lost or stolen, an SMS sent from any current, non-blocked user is permitted.
Change relay name: #0000#CNFG#RELAY_n#XXXXX#
Where “RELAY_n” is the text we want to change and where XXXXX is the text that replaces
the previous one. Note: the maximum length of the text is 13 characters.
Change input name: #0000#CNFG#INP_n#XXXXX#
Where “INP_n” is the text we want to change and where XXXXX is the text that replaces
the previous one. Note: the maximum length of the text is 13 characters.
Only when the Manager/MASTER sends a configuration SMS, the system answers that the
order has been executed with another SMS. If the format of the SMS is not correct, the
system will indicate so.
ERROR INDICATION
The receiver has visual and acoustic signs to indicate if there is any error.
INSTALLATION
This SMINN device is designed to be easily fixed on a wall using the provided screws and wall
plugs.
Before connecting the device to a power supply make sure the power supply is powered off.
Installation shall be done by specialized personnel using adequate wiring taking into
consideration that devices that are always powered on must have a power off override near
them (like a Miniature Circuit Breaker).
Internal connections shall be done following the indications depicted in the silk screen printing
of the board.
Once the device is programmed and verified, close it using the supplied lid and screws.
SMINN RECEIVERS HAVE AN EXTERNAL LIGHT TO INDICATE WHETHER THE DEVICE IS POWERED ON OR OFF
Note: Reinforced concrete, metallic parts and other radiofrequency devices can substantially
CE DECLARATION OF CONFORMITY
The company ELSON SISTEMAS, S. L.
Pol. Torrelarragoiti, P6 –A3 – 1ª
48170 Zamudio – Vizcaya (SPAIN)
Declares the following:
The product DOMO / DOMO+ GSM RECEIVER
Manufactured by ELSON ELECTRÓNICA, S.A.
Under the trademark
SMINN
For use in Residential, Commercial or light industry environments
Telecommunications: R&TTE, CE, FCC
Electromagnetic
compatibility:
EN 301489-1 v1.3.1 (2001-09)
EN 301489-3 v1.3.1 (2001-11)
Low voltage: N 60730-1: 2000
2010-03-30 - Zamudio
José Miguel Blanco Pérez
CTO of Elson Sistemas S.L.
innovative in electronics
T. 00 34 944 525 120
www. sminn.com
info@sminn.com
Pol. Torrelarragoiti, P6 - A3 - 1º
48170 Zamudio Bizkaia
GSM Module Dual Band 900/1800 Mhz
SMS Text mode
SIM
Integrated slot in board
Power 230VAC
Antenna 1/4 - 1/8 lambda MMCX Incluided
Temperature range -20ºC - +65º C
Dimensions
182 mm x 145 mm x 65 mm
(antenna not included)
Index of Protection
IP54 – IP65 with packing glands
SPECIFICATION LIST
BOX M GSM DOMO / DOMO+
Relays
User memory
Expansion socket (DOMO+ only)
For home automation and control. Includes
4 of 16 Amp. relays
Internal memory for up to 35 users
4 digital input card
1. ON Led
2. RUN/Status/Error led
3. SIM card
4. GSM module
5. Programming push button (PROG)
6. Buzzer
7.
Relays
8. Terminal Blocks
9. 230V AC power input
10. Protection fuse
11.
Expansion socket (DOMO+ only)
Fig.2
Housing ABS
COMPONENTS
ATTENTION
GSM SIM CARD´S PIN REQUEST MUST BE DISABLED FOR THE SYSTEM TO WORK
DOMO+ ONLY
Digital input card
COMPONENTS
1. Board connector
2. Input indicator led
3. Connection strip
3
2
1
Fig.1
DIGITAL INPUT CARD (DOMO+ ONLY)
The digital input add-on card allows the GSM DOMO+ to accept up to 4 connections from
normally closed (NC) sensors or alarm devices (temperature, water, gas, etc.) making possible
SMS alerts for those devices. (Fig.1)
Once a SMS alert has been sent the input must remain deactivated for at least 5 minutes to
originate a new alert.
NOTE: Each unused input must be connected to the COM Signal.
Input LEDs are normally powered on; An alert will be fired when the input circuit is open
and the input LED is off.
ALARM ALERTS (DOMO+ ONLY)
Alarm alerts can be configured for any registered user via the following messages:
Alert registration: #PPPP#SUBSCRIBE#XXXXXXXXX#
Alert unregistration: #PPPP#UNSUBSCRIBE#XXXXXXXXX#
Where PPPP is the administrative password and XXXXXXXXX is the phone number to register.
ERASE MEMORY
The phone numbers stored in the memory, as well as system configuration, can only be erased
deleting completely the memory. To do so, follow these steps:
- Disconnect the power supply.
- Press and hold the PROG button.
- Connect the power supply while holding PROG.
- Wait 8 secs until the RUN LED is switched on.
- Release the PROG button for 2 seconds.
- Press and hold again the PROG button.
- RUN LED will switch off.
- Wait 8 secs until the RUN LED blinks.
- Release the PROG button.
- Wait for a validation beep.
This procedure completely erases the system memory and leaves it in a checked factory state.
NOTE: In the PRO version, this procedure is only possible when the removable memory is
empty. To manage the external memory of the PRO version a CP100 programming console is
needed.
USE LIMITATIONS
Functionality is not guaranteed if used in different applications than the specified ones.
THE USAGE INSTRUCTIONS OF THIS EQUIPMENT SHALL BE HANDED TO THE USER, WHO WILLHAVE THEM
IN THEIR POSSESSION. IF THEY ARE MISLAID, THE USER CAN ASK FOR A COPY OR DOWNLOAD IT DIRECTLY
FROM THE WEBSITE WWW.SMINN.COM
The manufacturer reserves the right to change the specifications of these systems as well as
this manual without prior warning. The equipment must be manipulated only by specialized
and/or skilled personnel.
WARRANTY
This product has undergone a complete TEST during its manufacturing process that guarantees
its reliability and proper operation. The manufacturer provides 24 months of warranty to the
product from the date printed in the product and against any anomaly that it may present in its
appearance or operation. Any damage caused by third parties, natural causes (flooding, fire,
lightning, etc), arising from improper handling or installation, vandalism or any other cause non
attributable to the manufacturer will void the warranty.
The warranty only covers repairs or replacement of the damaged device. Any expenses derived
from assembling, travelling, transport, natural wear of parts, etc., and, in general, any expenses
that are not part of the repairs or replacement of the damaged element of the system are
excluded. The installer/provider will ask the manufacturer for an RMA number or authorization
for transport of the system in warranty. Without this previous requisite, the manufacturer will
not be able neither to process nor provide warranty service.
WARNING
This equipment meets the provisions contained in the article 3 of the R&TTE 1999/05/CE
Regulation, as long as its usage is compliant to what was envisaged, having applied the
following regulations:

This manual suits for next models

1

Other Sminn Receiver manuals

Sminn BOX M GSM B User manual

Sminn

Sminn BOX M GSM B User manual

Sminn BOX M 640 User manual

Sminn

Sminn BOX M 640 User manual

Sminn BOX M 440 User manual

Sminn

Sminn BOX M 440 User manual

Sminn BOX S 130 B User manual

Sminn

Sminn BOX S 130 B User manual

Sminn BOX M GSM B User manual

Sminn

Sminn BOX M GSM B User manual

Sminn BOX S 140 User manual

Sminn

Sminn BOX S 140 User manual

Sminn BOX M 240 User manual

Sminn

Sminn BOX M 240 User manual

Sminn BOX S GSM A User manual

Sminn

Sminn BOX S GSM A User manual

Popular Receiver manuals by other brands

Sirius Satellite Radio Streamer GT SIR-SL1C user guide

Sirius Satellite Radio

Sirius Satellite Radio Streamer GT SIR-SL1C user guide

Clarion UDB275MP owner's manual

Clarion

Clarion UDB275MP owner's manual

Cambridge Audio Azur 640R Technical specifications

Cambridge Audio

Cambridge Audio Azur 640R Technical specifications

SoundMax SM-CMD3008 instruction manual

SoundMax

SoundMax SM-CMD3008 instruction manual

Fortec Star PASSION+ user guide

Fortec Star

Fortec Star PASSION+ user guide

Motorola DCT1800 user guide

Motorola

Motorola DCT1800 user guide

Megasat HD 910 PREMIUM user manual

Megasat

Megasat HD 910 PREMIUM user manual

PCB Piezotronics 080A57 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 080A57 Installation and operating manual

Sony HCD-DZ7T Service manual

Sony

Sony HCD-DZ7T Service manual

Team Electronic RX-EP-U manual

Team Electronic

Team Electronic RX-EP-U manual

General Instrument DSR 922 Operator's guide

General Instrument

General Instrument DSR 922 Operator's guide

EDOBE XDOM CL85 - PRODUCTSHEET Dimensions

EDOBE

EDOBE XDOM CL85 - PRODUCTSHEET Dimensions

FSR HD-HAUD-SP-RX user manual

FSR

FSR HD-HAUD-SP-RX user manual

Favero 265-10 Installation and service manual

Favero

Favero 265-10 Installation and service manual

Softel SR1002 Mini FTTH manual

Softel

Softel SR1002 Mini FTTH manual

Universal Remote Control RFX-250i installation manual

Universal Remote Control

Universal Remote Control RFX-250i installation manual

Harman Kardon AVR 245 Reference manual

Harman Kardon

Harman Kardon AVR 245 Reference manual

ABB 3299-20408 quick start guide

ABB

ABB 3299-20408 quick start guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.