Installing the inverters and connecting the
module strings to the inverters
Caution!
Make sure that the inverter ON/OFF switch and the AC circuit breaker are both set to OFF
while installing the inverter.
Mount the installation bracket on the wall with the U-shaped notches facing upwards.
Make sure that there is sucient free cooling space around the inverter: 20 cm above and
below, 10 cm at both sides.
Connect the DC output cables from the SOLON SOLraise module strings to the DC inputs on
the underside of the inverter.
Check for correct polarity before connecting!
Unscrew the six retaining screws from the cover and open the inverter.
Connect the AC cable. Make sure that the inverter is correctly grounded.
Connect the Ethernet cable (internet connection) or RS485 cable (inverter coupling) if required.
Caution!
When the PV system is connected to the Internet, the IP address and the serial numbers of the
modules, power optimizers and inverters are transferred to the monitoring server. If this is not
desired, do not connect the PV system to the Internet.
The "mySOLON Monitoring Portal Terms and Conditions" are available at
www.solon.com/global/solraise.
Details for the setup of the communication between the inverter and the SolarEdge Monitoring
Server are available in the "Communication Setup Application Note" on the SolarEdge homepage:
www.solaredge.com/files/pdfs/solaredge-communication-setup-application-note.pdf
DC input
ON / OFF switch
RS232
LCD switch
AC output
Communication cable screw connections
DC input
Alignment of the mounting bracket