Electronic Distance
Measuring Tool
Pocket Reference Guide
Multi-
Measure 60
PRO
Multi-
Measure 60
PRO
®
®
- 1 -
KEYS AND THEIR FUNCTIONS:
ON/OFF Applies power to unit.
The 60 PRO will not turn on until
or is pressed.
Measures from bottom of unit
icon will appear in the lower right
corner of the display.
Measures from top of unit
icon will appear in the lower right
corner of the display.
Using either button: Press and HOLD to track
measurements - for continuous readings while
mo ing. Fastest way to measure but no reading
alidation. Useful for locating correct surfaces
when there are obstacles in the way.
Press and RELEASE to alidate measurement only
when unit is held absolutely still. Most accurate
mode. Useful in en ironments when obtaining a
stable reading can be difficult. Validates all
measurement before displaying. Filters out noise
from machinery and other sources.
Turns on Memory. Cycles through memory
registers.
Stores data displayed into blinking memory
registers.
Recalls memory from blinking memory
registers.
Multiplies measurements for area and
olume. Stores and recalls memory.
- 2 -
Adds linear distances, areas and olumes.
Stores and recalls memory.
Subtracts linear distances, areas and
olumes.
Clear/Convert/Off Button.
Press and immediately release to clear
display. Press and hold for two seconds to
change display units. Press twice to turn
unit off.
Press and Hold key for more than 2 seconds
to change display units. The display will cycle
between m, ft:in, ft:ft and yd. Release key to
select desired mode.
TAKING A MEASUREMENT /
GETTING STARTED:
1) Install a fresh 9V alkaline battery in rear of
unit. Push contacts firmly in place.
2) Aim cone at a hard, flat, unobstructed surface
such as a wall or mirror.
3) Make certain you ha e a clear path to the
surface (wall). (See FIG.1)
4) Hold Recei er perpendicular to the surface.
(See FIG. 2)
- 3 -
5) Press or until a consistent measure-
ment appears (about 2 seconds). The unit will
continue to take and display rapid measure-
ments as long as the button is held. Release
button to freeze the measurement.
Press and release or to alidate
measurement.
6) Your unit is factory preset to display metric. To
set your display to desired mode (m, ft:in,ft:ft
or yds) Press and hold button until desired
mode displays, then release.
NOTE: Unit will now default to your preset
mode e en after unit is turned off.
HELPFUL MEASURING HINTS:
1) Measurements cannot be taken through glass
or off of soft or padded surfaces.
2) The SONIN 60 PRO's range and ability to
measure in tight spaces can be increased.
Stand in the middle of the distance to be
measured and add measurements taken in
opposite directions.
3) When measuring in confined spaces (hallways),
try to measure down the center line and midway
between the floor and ceiling.
FIG. 1 - The sound waves emitted from this unit
spread 1 ft (30 cm) for every 10 ft (3m) measured.
SONIN INC.
Phone: 800-223-7511  Website: www.sonin.com
© 2003 Sonin Inc. ll Rights Reserved
Printed in China 054-1400-0070 Rev.2
#10065
YES NO YES NO
(FIG. 2)
- 4 -
4) To find a specific distance from a wall, walk
toward or away from the wall while holding
down or .
5) When the surface being measured to has
protrusions and recesses, you can determine
where the beam is hitting. Mo e sideways,
parallel to the target, while holding down
or . You will see the distance increase
for recesses and decrease for protrusions.
6) Be sure the surface you are measuring to is
hard, flat and uniform. Some surfaces such as
stucco or clapboard may scatter signals.
7) When tracking, the unit may lock on to a
stronger (usually closer) measurement. If this
happens, release and try again.
8) Remember:
Measures from bottom of unit.
Measures from top of unit.
READING THE DISPLAY:
The SONIN 60 PRO can display measurements
in 4 modes.
- 5 -
To change the display units or con ert a displayed
alue from one set of units to another, press and
hold . The displayed alue will change with
the units. Release when the desired units are
displayed. If you release before the reading changes
units, the display will clear and the reading will be
erased.
1) If the unit is unable to take a "good" measure-
ment the display will show one of the following:
BLANK SCREEN Make certain
the ON/OFF switch is in the ON
position. Check/replace battery.
If unit still doesn't work, call
your SONIN Dealer.
When the BATT symbol appears
on the display, replace the battery.
Out of Range or No Return Signal.
No Valid Reading.
Possible causes for Error 1 and Error 2 include:
a) Measurement out of range
(1.5 to 60 ft or 0.46 to 18.2 m).
See Specification Section on Range.
b) Unit is not perpendicular to the surface.
c) Surface is not hard and flat.
- 6 -
d) Interference from external noise sources
(see section on Environmental
Conditions).
e) Unit was mo ed during the measurement.
When using the alidate mode, the unit
must be held stationary.
Math error - square or cube result
o erflow.
2) If you get readings which are excessi ely long
or short, the likely causes are:
a) The unit is not being held parallel to the
floor. Hold the unit parallel to the floor
and at 90° to the surface being measured
to.
b) Measuring path is not clear of obstructions
or it is not wide enough. (See FIG. 1.)
c) The surface you are measuring to not
sufficiently flat and the sound wa es are
continuing to rebound. Place a flat object,
such as a board or mirror against the
surface and measure to the object.
d) En ironmental factors such as noise from
machinery or close proximity to an air
conditioner or computer screen.
3) If you get readings that are too short for the
distance being measured, make sure there is
a clear and sufficiently wide path to the surface.
Remo e any objects in the way or select a
different surface to measure to. (See HINT #2
for help.)
4) Range and accuracy can be affected by
en ironmental factors such as wind, tempera-
- 7 -
ture, humidity and altitude (see section on
Environmental Conditions).
COMPUTATION FUNCTIONS:
To make the computations in the descriptions
below, the button symbol indicates taking an
actual measurement (length, width or height) with
either the or the button.
Multiplying: The unit multiplies linear
measurements to compute areas and
olumes. The symbol will appear in
the upper left corner of the display.
Adding: The unit adds linear measure-
ments, areas or olumes. The symbol
will appear in the upper left corner of
display.
Subtracting: The unit subtracts linear
measurements, areas or olumes. The
symbol will appear in upper left corner of
display.
Adding distances:
Press
(Display shows , , or )
(Continue until you are done adding distances.)
Subtracting distances:
Press
(Display shows , , or )
(Continue until you are done subtracting
distances.)
Multiplying to compute areas:
Press
(Display shows , or )
meter decimal feet
yard foot:inch
Battery Low
Indicator
Bottom & Top
Measuring Icon
Units / Sq / Cu
Icon
Memories
Register
Six Digits & raction
Data Display Line
Multiply & Add
Memory Register
- 8 -
Multiplying to compute volumes:
Press
(Display shows , or )
To add areas:
Press
(Display shows total area)
(Continue until you are done adding areas.)
To add Volumes:
Press
(Display shows total olume)
(Continue until you are done adding olumes.)
Note: The SONIN 60 PRO can only add like units
of measure.
MEMORIES:
Your SONIN 60 PRO has SEVEN Memories total.
5 Memory Registers - M1, M2, M3, M4 and M5
and two mathematical memories in and .
To Access M1 M5 Memory Registers:
Press Key Once to Turn On Memory. If any
memory is already stored, the icon will appear
on the LCD showing where there is stored data,
otherwise it remains blank indicating all memory
registers are empty.
Continue to press and release the key to
access the memory registers. The icons will blink
when accessible. (i.e. , , , and/or
blinking)
NOTE:
1) When M1 - M5 icons are blinking and the
key is pressed, it will clear the memory
in that register.
- 9 -
2) If you plan to store a new measurement, you
must first take the measurement before entering
into memory.
3) To exit Memory, continuously press the
key until Memory Registers no longer appear
on the LCD. NOTE: the unit will automatically
exit memoy mode when you clear the memory,
store to memory or recall the memory.
To Store Memory:
Take a measurement. Press and release the
key until you reach the desired memory register.
Then, while blinking, press the key once to
store the displayed reading. The memory symbol
will now turn off to indicate that it has data stored.
to that register and back to measuring mode.
Example: To store in M3
Press once, and press 4 times -
(the icon will blink) then press .
Your measurement will be stored in M3.
To Recall Memory:
Press and release the key until you reach the
desired memory register. Then, while blinking,
press the key. This will recall the data stored
in that memory register.
Example: To recall from M3
Press until is blinking.
While blinking press key.
Memory stored in M3 will display on LCD.
To Clear All Stored Memory:
Press key until all 5 Memory icons are blinking.
Then press key. All memory stored will be
erased and your unit will automatically go back
to measuring mode.
- 10 -
To store in :
Press or , then (the " " symbol
will appear in the upper left corner of the
display)
To store in :
Press or , then (the " " symbol
will appear in the upper left corner of the
display)
NOTES:
1) Turning the unit off will erase both and
memories.
2) If memory is empty (no symbol in upper
left corner of display) a measurement can be
stored by pressing .
3) If memory is empty (no symbol in upper
left corner of display) a measurement can be
stored by pressing .
4) Subsequent measurements can be added to
or subtracted from measurement in by
pressing or botton, respecti ely. The
resulting alue (sum or difference) is displayed.
5) Subsequent measurements can be multiplied
by the stored alue (measurement or area) in
by pressing . The resulting alue (area
or olume) is diaplayed.
6) Other operations such as computing the area
formed by the sum of two distances multiplied
by a third distance are also possible.
For example:
- 11 -
7) The SONIN 60 PRO can only add like units
of measure. If contains a distance and the
display shows an area, pressing the
button will cause the area to be stored in
and the pre iously stored distance to be lost.
To retrieve a stored value in
and :
1) Clear the display by pressing and immediately
releasing the button.
2) Once you ha e cleared the display, press the
or button to retrie e the reading
stored in that memory.
- 15 -- 14 -
the unit's internal temperature to equal the air
temperature or, add 1% of the measured distance
for each 10°F (5.5°C) that the measured tempera-
ture is below the actual temperature; subtract 1%
of the measured distance for each 10°F (5.5°C)
that the internal temperature is abo e the air
temperature. (See section on DISPLAYING
TEMPERATURE for instructions on how to obtain
a temperature measurement from your SONIN 60
PRO.)
Altitude/Barometric Pressure - Altitude and
barometric pressure can affect the range and
accuracy of all ultrasonic distance measuring tools.
As the altitude increases (barometric pressure
decreases), the range is reduced. As altitude
decreases (barometric pressure increases), the
range is increased. To correct for altitude (pressure)
effects on accuracy, subtract 0.4% of the measured
distance for each 1000 ft/ - 0.6" Hg (0.3 km/-
15mm Hg) you are abo e sea le el. Add 0.4% of
the measured distance for each 1000 ft/ +0.6"
Hg (0.3km/+15mm Hg) you are below sea le el
(sea le el = 760mm Hg).
Noise - High frequency noise from machinery,
engines, computers, stereos, TV sets, etc. can affect
the reading and you may get random readings.
Stand away from or shut off this type of equipment
when measuring.
Outdoor Measurements - Your SONIN 60
PRO is designed for indoor use.
ENVIRONMENTAL CONDITIONS
THAT COULD AFFECT PERFORMANCE:
IMPORTANT: Ultrasonic Distance Measuring,
Tools work best for quick and easy measuring and
estimating. They are not intended for precision
work, although they can be ery accurate under
optimal conditions.
Humidity - Humidity and temperature can affect
the range and accuracy of all ultrasonic distance
measuring tools. They may gi e measurements
that are longer or shorter than their specifications
(depending on atmospheric conditions). The range
is longest in high temperature/high humidity and
low temperature/low humidity and range is shortest
in high temperature/low humidity and low
temperature/high humidity.
Humidity effects on accuracy are greatest at high
temperatures and negligible at low temperatures.
At 100°F (38°C) and 99% R.H., the distance
measurement will be short by 0.6%. At 100°F
(38°C) and 0% Relati e Humidity, the distance
measurement will be long by 0.6%. At 32°F (0°C)
the distance measurement will essentially not be
affected.
Temperature - Your SONIN 60 PRO has unique
automatic temperature compensation to ensure
consistency of measurements between 32°F and
100°F (0°C to 38°C). The response rate of this
circuitry enables you to mo e between warm and
cold areas and measure with reasonable accuracy.
Howe er, we recommend that you do not lea e
your SONIN unit in ery cold or ery hot conditions
(e.g. sunlight in a car), as the unit will then require
more time to adjust to air temperature.
As long as the internal temperature is equal to the
air temperature, accuracy is unaffected. Wait for
- 13 -
SPECIFICATIONS:
Range:
Min: 1.5 ft (0.46 m)
Max: 60 ft (18.2 m)
Actual: Will ary depending on en ironmental
conditions.
Accuracy:
99.5% ±1/4 in (or 99.5% ±1 cm)
When en ironmental conditions are as follows:
Temperature: 32 to 86°F (0 to 30°C)
Relati e Humidity: 30 to 70%
Altitude: -328 to +328 ft (-0.1 to +0.1 km)
Wind Speed: Still Air
Example:
At 15 ft (4.57 m) your reading will be within
1 1/4 ins (3 cm). And at 60 ft (18.2 m) your
reading will be within 3 3/4 inches (10 cm).
Resolution:
1/4 in (0.01 ft, 0.01 m or 0.01 yd)
Ultrasonic Frequency:
40 kHz
Battery:
9 olt (alkaline recommended)
Current Consumption:
8 - 13 mA (Approximately 50 hours continuous
use with a new 9 olt alkaline battery)
Operating Temperature:
32 to 100°F (0 to 38°C)
Auto Shut off:
Approximately 7 minutes after last key press.
Size:
5 7/8 x 2 7/8 x 1 3/4 ins
(147 x 75 x 45 mm)
Weight:
6.2 oz (175 g) without battery
- 12 -
TEMPERATURE COMPENSATION:
Because temperature affects the speed of sound,
the SONIN 60 PRO has automatic temperature
compensation for greater accuracy. In order to
make the most of this feature, wait 1 minute for
each 1°F (2 minutes for each 1°C) of temperature
difference between cool and warm locations.
DISPLAYING TEMPERATURE TO IMPROVE
ACCURACY: Since temperature affects accuracy,
the SONIN 60 PRO is most accurate when its
internal temperature matches the air temperature.
To display temperature:
press and hold key, then press key, the
internal temperature will appear on the display
immediately (in °C when m display units are selected
or in °F if selected display units are ft:in, ft:ft, yds).
To go back to measurement mode, press and
release key or press the measure key directly.
HINT: To speed equalization of the SONIN 60
PROs internal temperature ersus air tempera-
ture, wa e the unit back and forth in the air to
circulate room temperature air through the unit.
For additional information, see "Temperature" in
the section on Environmental Conditions.
LOW BATTERY INDICATOR:
Replace the battery when the BATT symbol appears
on the LCD.
or
- 17 -- 16 -
FIELD CALIBRATION
This unit was calibrated under the circumstance
of 760 mmHg atmosphere and 50% relati e
humidity, if the unit is not used under such en iron-
mental conditions, it may produce an error. The
built in users calibration mode is designed for the
user working under other than standard conditions
such as high altitudes. After the unit is calibrated
all en ironmental errors are compensated and the
accuracy is impro ed.
To Field Calibrate unit
1) Turn the On/Off switch to the ON position.
2) Place unit 10 feet (or 3 meter) from the bottom
of the unit to a flat ertical surface.
3) Press and hold both and keys then
press key, the unit will turn on and process
calibration immediately.
4) When calibration is completed 10.00 ft.ft
(or 3.00 m) will displayed on the LCD.
5) Then turn off the unit and turn on again, the
new calibrated data will now used in all
measures.
NOTE BEFORE CALIBRATING UNIT:
1) It is imperati e that the unit be exactly 10 feet
(imperial) or 3 meter (metric) from the bottom
of the unit to a flat ertical surface.
2) Verify the temperature of the unit is within
± 1°C of the ambient temperature.
TO RESET BACK TO FACTORY DEFAULT
SETTING:
1) Turn OFF unit and turn in ON again.
2) Press and hold key then press . The
LCD will display (RESET). the
factory default setting now restored to the unit.
3) Then turn OFF unit and turn ON again to
resume measuring.
FCC NOTE:
This device has been tested and found to
comply with the limits for a Class B device,
pursuant to part 15 of the FCC Rules These
limits are designed to provide reasonable
protection against harmful interference in a
residential installation This device generates,
uses and can radiate radio frequency energy
and, if not used in accordance with the
instructions, may cause harmful interference to
radio communications However, there is no
guarantee that interference will not occur in a
particular installation If this equipment does
cause harmful interference to radio or television
reception, which can be determined by turning
the device off and on, the user is encouraged
to try to correct the interference by one or more
of the following measures:
- Reorient or relocate the receiving antenna
- Increase separation between the device
and receiver
This Class B Digital Apparatus meets all
requirements of the Canadian Interference-
Causing Equipment Regulations
TECHNICAL ASSISTANCE
If you have any questions or need technical
assistance, e-mail to:
[email protected]
CUSTOMER SERVICE
SONIN takes pride in offering unmatched
customer service to owners of SONIN
products If you have any questions or would
like additional information, please call:
1 - 800 - 223 - 7511 (USA)
or e-mail to:
[email protected]

This manual suits for next models

1

Other Sonin Measuring Instrument manuals

Sonin 10045 User manual

Sonin

Sonin 10045 User manual

Sonin 10075 User manual

Sonin

Sonin 10075 User manual

Sonin 10275 User manual

Sonin

Sonin 10275 User manual

Sonin 10075 User manual

Sonin

Sonin 10075 User manual

Sonin 10300 User manual

Sonin

Sonin 10300 User manual

Sonin 50211 User manual

Sonin

Sonin 50211 User manual

Sonin 10045 Multi-Measure 45 User manual

Sonin

Sonin 10045 Multi-Measure 45 User manual

Popular Measuring Instrument manuals by other brands

CBE MT214 user manual

CBE

CBE MT214 user manual

Amprobe VPC-20 instruction manual

Amprobe

Amprobe VPC-20 instruction manual

Sper scientific 850081 instruction manual

Sper scientific

Sper scientific 850081 instruction manual

Tenmars TM-730 user manual

Tenmars

Tenmars TM-730 user manual

Pyle PAH1 instruction manual

Pyle

Pyle PAH1 instruction manual

Baur TDR 500 user manual

Baur

Baur TDR 500 user manual

Endress+Hauser Levelflex M FMP40 Description of Device Functions

Endress+Hauser

Endress+Hauser Levelflex M FMP40 Description of Device Functions

Hioki MR8880-20 quick start guide

Hioki

Hioki MR8880-20 quick start guide

Fluke OptiView FiberInspector OPV-FT600 installation guide

Fluke

Fluke OptiView FiberInspector OPV-FT600 installation guide

Wonder SPA user manual

Wonder

Wonder SPA user manual

LaserLiner G40 manual

LaserLiner

LaserLiner G40 manual

Endress+Hauser Cerabar S PMP72 operating instructions

Endress+Hauser

Endress+Hauser Cerabar S PMP72 operating instructions

Neware BVIR user manual

Neware

Neware BVIR user manual

CHN Spec CS-600C Operation manual

CHN Spec

CHN Spec CS-600C Operation manual

Baylan TM-A user manual

Baylan

Baylan TM-A user manual

Amprobe THWD-2 instruction manual

Amprobe

Amprobe THWD-2 instruction manual

MRSI FoolProof user guide

MRSI

MRSI FoolProof user guide

ABB Nitrate 8236 instruction manual

ABB

ABB Nitrate 8236 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.