Sonoma WB SHW 1240 User manual

August 2022
INSTALLATION GUIDE
800.330.5553 [email protected]
Page 1 of 5
WaterBridge Floor-Mounted Exposed
Thermostatic Showers
WaterBridge Exposed Showers are available in four standard oor-mounted congurations:
WB SHW 1240 Rain head only
WB SHW 1250 Rain head and hand shower
WB SHW 1270 Rain head and foot wash
WB SHW 1280 Rain head, hand shower, and foot wash
Model 1240 Model 1250 Model 1270 Model 1280
It is strongly recommended that this, and all xtures,
be installed by a licensed professional plumber.

August 2022
INSTALLATION GUIDE
800.330.5553 [email protected]
Page 2 of 5
WaterBridge Floor-Mounted Exposed
Thermostatic Showers
These Waterbridge Exposed Showers are plumbed to
3/4” straight nipples, which are included with the
system. The Shower employs compression ttings to
attach to nipples that have been stubbed out. The
hot and cold lines should be plumbed 10” on center,
trimmed exactly 5/8” exposed from the nished oor.
Note: Do not use Tapered Pipe only provided Straight
Thread Nipples.
(See Fig. A)
Leg Riser
Swivel Nut
Rubber Washer
Fiber Washer
Flange
3/4” Straight Nipple
10” C to C
5/8” from
Finished
Floor or
Deck Cover Sleeve
Fig. A
Apply
O-rings
Swivel Escutcheon
Optional
Wall Plate
Mounting
Bracket
Mounting
Screws
Tape
Threads
or use
Joint
Compound
Pipe Stop (Sliding Bracket Only)
Locking Bushing (Sliding Bracket Only)
Outer Tube
Inner All-thread
Fixed or
Sliding
Bracket
Apply Glue
Sliding Bracket
Installed onto
Upper Riser
Fully thread
into Valve Body
so Riser
is oriented in
correct position
Trim Installation
1) This shower is provided with adjustable wall brackets
for uneven walls. These consist of an Inner
All-thread and a loose Outer Tube. These can be
adjusted to 2-1/2” – 7-1/2” from the wall to the
center of the shower’s vertical riser. Additionally, the
Brackets on the Foot Wash and Upper Risers can
be adjusted to dierent heights by sliding the bracket
up or down the pipe and locked into place using the
Pipe Stop and Locking Bushing. Use 7mm Hex
Wrench to tighten Locking Bushing.
THESE SHOULD BE INSTALLED AND ADJUSTED
BEFORE INSTALLATION OF THE SHOWER.
(See Fig. B)
2) Install Sliding Bracket onto Upper Riser and secure
into place at desired height. Be Careful not to
damage nish when installing bracket. Install the
Top Riser by applying the provided glue and
threading the male pipe into the Cross or Tee Body.
(See Fig. C)
Note: Make sure glue dries so the Top Riser and/
or Foot Wash are oriented in the correct position. The
threads should be pre-clocked from the factory so this
orientation is correct when fully threaded into the
body. The Pipes are sealed with 2 internal o-rings.
Be careful not to damage when installing the
pipes. Lubricate the inside of the pipes to help.
3) Use Thread Compound or Tape threads for the
Shower Arm and fully thread Shower Arm Into the
Elbow.
(See Fig. D)
Note: Make sure the Shower Arm is oriented in the
correct position. The threads should be pre-clocked
from the factory so this orientation is correct when
fully threaded into the Elbow.
Fig. B
Fig. C
Fig. D

August 2022
INSTALLATION GUIDE
800.330.5553 [email protected]
Page 3 of 5
WaterBridge Floor-Mounted Exposed
Thermostatic Showers
Rubber Washer
Ball Joint
Collar
8mm Hex Wrench
Shower Head
Shower
Arm
Trim Installation
4) Install the Rain Head:
a) Unscrew the Collar from the top of the Rain Head.
b) Thread the Ball Joint into the Shower Arm using
a 8mm Hex Wrench.
c) Tighten the Collar back onto the top of the Head.
(See Fig. E)
Note: The Shower Head is shipped with a Flow
Restrictor installed into the Ball Joint. This can be
removed for replacement.
Fig. E
Dry Wall
Anchors
1”
C to C
Mounting
Bracket
Mounting
Screws
Swivel
Escutcheon
Hand Shower Bracket Installation
1) For Shower Models (850 & 880) with Hand Shower;
a) For Drywall installation, drill holes for the Dry Wall
Anchors and Install. For Stud Installation, Drive in
the screws through the round holes in the
Mounting Bracket. Make sure the Mounting
Bracket is level and 1” center to center.
b) Using Mounting Screws, screw Mounting Bracket
to the wall and into the Anchors.
c) Thread the Swivel Escutcheon onto the Mounting
Bracket until tight. It is factory suggested to use a
Belt Wrench to tighten completely.
(See Fig. F)
Note: For added stability, it is factory recommended to
install Wall Bracket into a stud.
Fig. F
Final Check
1) Turn on Water Supply at source and check for leaks.
2) Check Thermostatic Controls, Volume Controls, Shut-os and/or Diverter for proper function.

August 2022
INSTALLATION GUIDE
800.330.5553 [email protected]
Page 4 of 5
WaterBridge Floor-Mounted Exposed
Thermostatic Showers
Shut-off
Limit Stop
Hot
Limit Stop
2) Setting Temperature Limit Stops:
There are two Limit Stops included with the cartridge.
The Shut-o Limit Stop does not need to be removed
and should remain in the position supplied from the
factory. The cartridge should not supply any water
when in this position.
The Hot Limit Stop will need to be adjusted so the max-
imum temperature of the mixed water is in accordance
with your local plumbing codes and standards.
a) Using a thermometer to measure the mixed water
temperature, adjust the Hot Limit Stop to desired
maximum hot water temperature.
Increase water temperature: Rotate Hot Limit Stop
clockwise on the stem.
Decrease water temperature: Rotate Hot Limit Stop
counter-clockwise on the stem.
(See Fig. H)
WARNING: Temperatures exceeding 110 degrees are
dangerous and may cause scalding, server injury
or death. This valve is NOT factory preset. Installer
must make the proper adjustments.
Fig. H
Set Screw
Friction
Washers
Trim Plate
Thermostatic
Cartridge
Control
Handle Valve
Body
Cartridge Calibration
Due to dierences in Pressures and Temperatures in
your system the Thermostatic Cartridge will need to be
Calibrated in accordance with your Local Plumbing
Codes and Standards.
1) Removing Trim
a) Remove the Control Handle by un-threading the
Set Screw. Remove the 2 Friction Washers.
b) Remove the Trim Plate by un-threading it from the
Valve Body.
(See Fig. G)
Fig. G

August 2022
INSTALLATION GUIDE
800.330.5553 [email protected]
Page 5 of 5
WaterBridge Floor-Mounted Exposed
Thermostatic Showers
Care & Maintenance
No abrasives should be used to clean Sonoma Forge products.
Mild soap and water can be used, and 100% carnauba wax can be applied to protect the nish.
All exterior plumbing should be winterized if freezing temperatures are expected..
Check
Valves
Removable Cap
Check Valve
Stops
Valve Plugs
Screen Filter
Thermostatic
Cartridge
Wrench
Flats
1) Replacing Check Valves:
Do not remove Check Valves unless you have replace-
ments. Any Check Valves Removed from the Valve Body
must be replaced.
The water supply to the Shower must be turned o before
replacing Check Valves or Cartridge.
a) Using a 1/4” Hex Wrench, Remove the Valve Plugs.
b) Remove Check Valve Stops and Screen Filters.
Note: Do not Remove the Valve Plugs Above and
Below the Cartridge. These are permanent Plugs.
c) Using a hook or pick remove Check Valves and
discard.
d) Replace Check Valves orienting them so water ows
in the direction as shown in Fig. I
e) Reassemble Plugs and Trim in reverse order.
f) Turn on water supply and check for leaks and
ensure valve is functioning correctly.
Note: The Shower Systems can be drained, above
the Valve Body, using the Removable Cap for
models 1240 & 1250 or opening the Shut-os on the
Foot Wash for models 1270 & 1280.
Note: Water Supply to the Shower must be turned o
before draining.
(See Fig. I)
2) Replacing Cartridge:
a) Un-thread the Cartridge counter clockwise from the
Body Using the ats on the Cartridge.
b) Replace the Cartridge and Trim
c) Turn on water supply and check for leaks and
ensure valve is functioning correctly.
(See Fig. J)
Fig. I
Fig. J
This manual suits for next models
3
Table of contents
Popular Bathroom Fixture manuals by other brands

Gessi
Gessi VENTI20 65012 manual

Aqualisa
Aqualisa Quartz Electric installation guide

Fleurco
Fleurco Cordoba Plus CKU4832-11-40 installation manual

Porcelanosa
Porcelanosa noken 100165529 N899999770 instructions

Salvatori
Salvatori ANIMA BASIN manual

Fantini Rubinetti
Fantini Rubinetti ACQUADOLCE L001B instructions