SITUATION
FEATURES
DESCRIPTION
APPLICATION NOTES
S
IT
U
ATI
ON
FEATURE
S
DE
SC
RIPTI
O
N
APPLI
C
ATI
O
N N
O
TE
S
Contact: Sonora Design Associates t805.644.8913 twww.sonoradesign.com t[email protected]
Revised Nov 13 2013
POWER SUPPLIES
SOLUTION
RELATED CONSIDERATIONS
4SATPL-T POLARITY LOCKER
The DIRECTV® (4) polarity SlimLine® dish with SL5
LNB to receiver distance exceeds 100 feet. (Reference
SlimLine® installation manual)
Model 4SATPL-T powers a DIRECTV® SlimLine® dish
with strong DC levels and polarity locks the four dish
outputs relieving the receivers from powering the LNB.
Power from the PS242000A included with the
4SATPL-T may be looped to power a model LA144R
amplifier.
Color coded jumpers are suggested to be
sure the polarities are maintained to the switch.
• DBS Compatibility . . . . . . . 4 Polarity DIRECTV®SlimLine®
• 2 Amp Power Supply . . . . . powers LNBs & line amplifiers
• Locks LNBs . . . . . . . . . . . . one polarity on each of (4) coax
• Blocks 22 kHz . . . . . . . . . . . . . . . . . from multiple switches
• Indoor / Outdoor case. . . . . . . . . . . . . . Die cast Aluminum
DIRECTV® 4 polarity SlimLine® Ku/Ka polarity
locker and power booster.
DC
DC
4SATPL
PS24
2000A
DC
DC
LA144R
IN 1
OUT 1 OUT 2 OUT 3 OUT 4
IN 2 IN 3 IN 4
101
99
SL5
103
110 119
DIRECTV®
16 Channel SWM
SWM2
Legacy 1 Legacy 2 Legacy 3 Legacy 4 Flex1Out Flex2Out
DCPWR SWM1PWR
Sat 99º / 101º
18V 13V
Port1
Flex
Port2
Flex
Sat 103º/110º/119º
18V/22kHz 13V/22kHz
PS24
2000A
Blocks
Locks
Powers
DIRECTV® recommends that the distance between
receiver and dish be less than 150 feet of solid
copper RG-6. At distances greater than 150 feet they
recommend a DC voltage booster and a line amplier.
Model 4SATPL-T provides LNB powering and strong
control signal to lock the dish. Without the locker, the
SWM16 which must power the LNB.
Model LA144R ampliers may be powered by the
polarity locker for installations with long switch to
dish or receiver to switch installations.
SPECIFICATIONS
S
P
E
C
I
F
I
C
A
T
I
O
N
S
Contact: Sonora Design Associates t805.644.8913 twww.sonoradesign.com t[email protected]
Revised Nov 13 2013
Specications .......................Typical ..................QC Limit
Inputs / Outputs ........................................... (4) @ 5 to 2400 MHz
Insertion Loss.................................. 0.5 dB............................... 1 dB
Return Loss 54-2400 MHz.......... 12 dB..............................10 dB
Power Specications
Input Transformer ................................................24 VDC, 2 Amp
100 to 240 VAC input, switching, short circuit protected
Output Voltages and tones
101º& 99º (Odd) RHCP .....................................................14 Vdc
101º & 99º (Even) LHCP....................................................20 Vdc
119º & 103º (Odd) RHCP ...............................22 kHz & 14 Vdc
110º/119º & 103º (Even) LHCP.....................22 kHz & 20 Vdc
Mechanical Specications
Dimensions ..................................................... 6”L x 3.5”W x 7/8”H
Weight ...................................................................... 1.75 lb (0.8 kg)
Master Carton (18 units) ........................................20” x 10” x 10”
Master Carton Weight........................................... 34 lb. (15.5 kg)
Environmental Specications
Operating Environment: .................Indoor/Outdoor Lock box
Ambient Temperature..........................................-30º C to +70ºC
POWER SUPPLIES
4SATPL-T POLARITY LOCKER
A common problem for installers is maintaining the
correct trunk to switch polarity. Use the test channels
to verify trunk polarity.
Cables from the Polarity locker outputs must
match switch input voltages:
20V to 18V,
14V to 13V,
20V/22k to 18V/22k
14V/22k to 13V 22k.
13 13
22k
18
22k
18 FLEX
1FLEX
2
WB68
Switch
Blocks
Locks
Powers
DC
DC
4SATPL
PS24
2000A
250.MHz..........................750..950............................................1450...1680.............................2150
DISH
9506 99ºc 99ºs
DIRECTV® SL5 LNB Ka / Ku Frequency Plan Updated:
MAR 30, 2013
101º9501
11
1
753 3
1
2
9
2
7
2
5
2
3
2
1
1
9
1
7
1
5
1
3
9
11
1
753 1 53
1
3
1
5
1
7
1
9
2
1
2
3
9
13V
9507 99ºc 101º9502
21
2
864 3
2
3
0
2
8
2
6
2
4
2
2
2
0
1
8
1
6
1
4
1
0
21
2
864 2 6 8
1
0
1
2
1
4
1
6
1
8
2
0
2
2
2
4
4
1
4
1
6
1
8
2
0
2
2
2
4
1
0
18V
103ºca 9508103ºcb9510
13V &
22kHz
1 9753
7
1
3
1
5
1
7
1
9
2
1
2
3
1
1
119º 9513
1 9753 1
1
1
3
1
5
1
7
1
9
2
1
2
3
2
5
2
7
2
9
3
1
1
9
1
7
9
1
1
1
3
1
5
2
1
2
3
103ºca9511 103ºca 9509
110º 9512 119º 9514
21
2
864 3
2
3
0
2
8
2
6
2
4
2
2
2
0
1
8
1
6
1
4
1
0
21
2
864 1
6
1
8
2
0
2
2
1
0
1
6
1
4
1
2
1
8
2
0
2
2
2
4
18V &
22kHz
1
0
8
2
4
6
4
2
13 5
DIRECTV® receivers and the AIM meter are programed
to measure the transponders targeted for specic zip
codes. The signal meter in the receivers can be used to
verify the transponders for your region.
DIRECTV® provides test channels to verify the reception
of specic transponder on each polarity. The test channel
numbers associated with transponders is provided.
TEST CH VOLTS MHz SAT XPNDR
9506 13 274 99º c1
9501 13 974 101º 1
9507 18 274 99º c2
9502 18 989 101º 1
9510 13 / 22k 274 103º cb1
9513 13 / 22k 1353 119º 27
9508 13 / 22k 2120 103º ca23
9511 18 / 22k 274 103º cb2
9512 18 / 22k 1105 110º 10
9514 18 / 22k 1426 119º 32
9509 18 / 22k 2120 103º ca24
Contact: Sonora Design Associates t805.644.8913 twww.sonoradesign.com t[email protected]
Revised Nov 13 2013
3
4SATPL-T TRUNK POWER INSERTER
SL5 ODU Power Inserter and Tone Generator Unit
Features: Simplies MDU installations by providing
an integrated module for locking LNB polarizations
and satellite selection
Parameter UNIT 4SATPL-T
Operating Frequency Range MHz 250 - 2150
Insertion Loss dB 1.5 (max.)
Flatness in operating frequency range dB ± 0.5
Number of Input Ports Each (4) F
Number of Output Ports Each (4) F
Isolation between ports dB > 35 dB
Input / Output Return Loss dB > 12 (min)
DC Power provided to inputs VDC
Port #1 (20 V 101º & 99º) VDC 20 ± 0.5
Port #2 (13 V 101º & 99º) VDC 13.5 ± 0.5
Port #3 (22 kHz & 20 V 119º & 103º) VDC 20 ± 0.5 (+ 22 kHz)
Port #4 (22 kHz & 13 V 119/110º & 103º) VDC 13.5 ± 1 (+ 22 kHz)
Number of LEDs Each 5 (1 per input & 1 for adaptor input)
22 kHz Tone to ODU kHz
Frequency kHz 22.0 ± 0.5
Duty Cycle % 50
Amplitude mVpp 800 (min)
DC Power Path mA 1000 (max.) From DC Input to each
Input
DC Power Connector Type Each (1) F
Switching Mode Power Supply 24 V, 1.2A (min)
Short Circuit Protection Yes, Multi fuse
Lightning Surge Protection 32V p-p, max shunt current 200A; 8
msec, 1.5kW max dissipation
Ground Screws Each (1) Ground Screw.
Dimensions L x W x H mm 58 x 188 x 23
Environmental Requirements Indoor use only
Operating Temperature range ºC -34 to + 60 Indoor housing
Humidity Shall survive exposure to 95% relative
humidity over operating temperature
4SATPL-T Trunk Power Inserter
• Powers SL5 ODUs
• Regulated DC Voltages
• F-Connector Power Input
• Power LED Indicators
Contact: Sonora Design Associates t805.644.8913 twww.sonoradesign.com t[email protected]
Revised Nov 13 2013
4
POWER SUPPLIES
4SATPL-T POLARITY LOCKER
DIRECTV® recommends that the distance between
receiver and dish be less than 150 feet of solid copper
RG-6. Here is why.
Model SL5 LNBs employ current management to
minimize the current carried per coax. (540 mA total)
18 V = 220 mA, 18V 22kHz = 220 mA, 13V = 50 mA,
13V 22kHz = 50 mA.
The 18 volts originating at the SWM8 must arrive
at the SL5 above 16 volts for the SL5 to operate
correctly. Up to (2) volts can be lost in the coax.
Resistance = Voltage loss / Current
18 V - 16 V = 2 volts / 0.22A = 9 ohms
Solid copper cable has a DC loop resistance of 4
ohms per 100 feet. Copper covered steel has a DC
loop resistance of 8 ohms.
Copper Covered steel = 9 ohm / 8 = 112 feet
Solid Copper = 9 ohm / 4 ohm = 225 feet
Model 4SATPL-T starts with 19.7 Volts to provided
extended dish to home distances.
The extra 1.7 volts buys extra RG-6 distance. The
extra coax distance increases the signal loss which
model LA144R osets.
Ampliers near the dish increase the current draw
and increase the voltage loss to the dish. Model
LA144R draws 3.2 Watts. (200 mA @ 16V). The total
current on the 19.7 volt coax is (220 mA for the LNB
+ 200 mA for the LA144R) = 400 mA
What is the maximum distance that a 19.7 Volt supply
can power an SL5 LNB + LA144R with RG-6 cable?
(19.7 V - 16 V) / 0.4 AMP = 9 OHMS
Copper Covered steel = 8 ohm / 8 = 112 feet
Solid Copper = 8 ohm / 4 ohm = 225 feet
If the dish is greater than 225 feet (RG-6), model
LA144R cannot be placed at the dish.
16 V minimum
19.7 V
225 feet RG-6
DC
DC
4SATPL
PS24
2000A
DC
DC
LA144R
IN 1
OUT 1 OUT 2 OUT 3 OUT 4
IN 2 IN 3 IN 4
DC
DC
LA144R
IN 1
OUT 1 OUT 2 OUT 3 OUT 4
IN 2 IN 3 IN 4
101
99
SL5
103
110 119
-27/-38 dBm
-28/-39 dBm
-20/-16 dBm
-30/-30 dBm
-38/-40 dBm
-28/-26 dBm
SEQ409
18 Vdc, 0.22 Amp
16 Vdc Minimum
SWM8 Powering of SL5
24 Vdc
200 ft RG-6
4 ohms / 100 ft
worldDIRECT
10195
DIRECTV®
8 Channel SWM
OFF-AIR
Legacy 1 Legacy 2 Legacy 3
SWM2 SWM1PWR
Sat 99º / 101º
18V 13V
Port1
Flex
Port2
Flex
Sat 103º/110º/119º
18V/22kHz 13V/22kHz
PS24
2000A
101
99
SL5
103
110 119

Popular Controllers manuals by other brands

Mitsubishi Electric MELSERVO JET Series user manual

Mitsubishi Electric

Mitsubishi Electric MELSERVO JET Series user manual

Allen-Bradley PowerFlex 525 Original instructions

Allen-Bradley

Allen-Bradley PowerFlex 525 Original instructions

Pixsys DRR244 user manual

Pixsys

Pixsys DRR244 user manual

OPTO 22 SNAP PAC S Series user guide

OPTO 22

OPTO 22 SNAP PAC S Series user guide

Siemens SIMATIC S7-1500R/H manual

Siemens

Siemens SIMATIC S7-1500R/H manual

Unitronics Vision OPLC V130-33-B1 installation guide

Unitronics

Unitronics Vision OPLC V130-33-B1 installation guide

BEKA BA550 Series manual

BEKA

BEKA BA550 Series manual

Superior Electric STABILINE WHR34 S Series instructions

Superior Electric

Superior Electric STABILINE WHR34 S Series instructions

WAREMA KNX MSE 6M230 Series Operating and installation instructions

WAREMA

WAREMA KNX MSE 6M230 Series Operating and installation instructions

Tranquil-Easy HC 7360H operating instructions

Tranquil-Easy

Tranquil-Easy HC 7360H operating instructions

Sigma Myriad LC1 Series instruction manual

Sigma

Sigma Myriad LC1 Series instruction manual

LeakSmart Snap Valve Controller System user manual

LeakSmart

LeakSmart Snap Valve Controller System user manual

IWAKI PUMPS ST-900N instruction manual

IWAKI PUMPS

IWAKI PUMPS ST-900N instruction manual

Pentair FLECK 2750 NXT2 user guide

Pentair

Pentair FLECK 2750 NXT2 user guide

Motion Access CONDOR SWING MA50777 Installation & operation manual

Motion Access

Motion Access CONDOR SWING MA50777 Installation & operation manual

Wise Controls WisePack Simple Instructions

Wise Controls

Wise Controls WisePack Simple Instructions

Aaeon AEC-6402 manual

Aaeon

Aaeon AEC-6402 manual

TECNARE DP Series Operation manual

TECNARE

TECNARE DP Series Operation manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.