– 15 –
TAPE OUT L-CH : CN05 pin
2
(MAIN board) R-CH : CN05 pin
4
TAPE OUT L-CH : CN05 pin
2
(MAIN board) R-CH : CN05 pin
4
Record Bias Adjustment
Setting : Set to the TEST mode. (See page 5.)
Procedure :
1. Connection for recording :
speed checker
or
frequency counter
47 k
Ω
set
test tape
WS-48A
(3 kHz, 0 dB)
Tape Speed Adjustment
Procedure :
1. Connect the speed checker or frequency counter as shown below
and set FWD playback mode.
2. Adjust the capstan motor (M1) volume so that the reading on the
speed checker or frequency counter falls within the following
adjustment value.
Adjustment Value : normal speed
Speed checker Frequency counter
– 3 to + 3 % 2,910 to 3,090 Hz
Confirm that the deviation between tape top and tape end is within
3%.
Adjustment Location : Capstanmotor (M1)volume(Seepage16.)
Sample Value ofWow and flutter
W. RMS (JIS) within 0.3%
(test tape : WS-48A)
Playback Level Adjustment
Procedure :
1. Connect the speed checker of frequency counter as shown below
and set FWD playback mode.
2. AdjustSFR03(L-CH)andSFR04 (R-CH)onAMPLIFIERboard
so that the reading on the level meter falls within the following
adjustment value.
Adjustment Value :
TAPE OUT level Level difference
between channels
– 4 ±2 dB (0.39 to 0.62 V) within 2 dB
Confirm that the TAPE OUT level does not change even if Playback
and Stop operation is repeated several times.
Adjustment Location : AMPLIFIER board (See page 16.)
level meter
47 k
Ω
set
test tape
P-4-L300
(315 Hz, 0 dB)
2. Connection for playback :
3. In the connection of item 2, playback the signal recorded in the
connection of item 1, confirm that the reading on the level meter
falls within the following adjustment value.
4. If these levels do not adjustment value, adjust SFR01 (L-CH)
and SFR02 (R-CH) on AMPLIFIER board to repeat items 1
and 2.
AdjustmentValue :Difference of playback output of 10 kHz to
playback output of 315 Hz : 0 ±0.5 dB
Adjustment Location : AMPLIFIER board (See page 16.)
Record Level Adjustment
Setting : Set to the TEST mode. (See page 5.)
Procedure :
1. Connection for recording :
2. Connection for playback :
3. In the connection of item 2, playback the signal recorded in the
connection of item 1, confirm that the reading on the level meter
falls within the following adjustment value.
4. If these levels do not adjustment value, adjust SFR11 (L-CH)
and SFR12 (R-CH) on MAIN board to repeat items 1 and 2.
AdjustmentValue :Playback output level of 315 Hz :
– 4 ±2 dB (0.39 to 0.62 V)
Adjustment Location : MAIN board (See page 16.)
level meter
47 k
Ω
set
recorded portion
AF OSC
attenuator 10 k
Ω
set
600
Ω
blank tape
CS-123
AF OSC
attenuator 10 k
Ω
set
600
Ω
blank tape
CS-123
level meter
47 k
Ω
set
recorded portion
TAPE IN L-CH : CN05 pin
1
(MAIN board) R-CH : CN05 pin
5
1) 315 Hz
2) 10 kHz 43.6 mV (– 25 dB)
TAPE OUT L-CH : CN05 pin
2
(MAIN board) R-CH : CN05 pin
4
TAPE IN L-CH : CN05 pin
1
(MAIN board) R-CH : CN05 pin
5
315 Hz, 0.49 V (– 4 dB)
TAPE OUT L-CH : CN05 pin
2
(MAIN board) R-CH : CN05 pin
4
w
w
w
.
x
i
a
o
y
u
1
6
3
.
c
o
m
Q
Q
3
7
6
3
1
5
1
5
0
9
9
2
8
9
4
2
9
8
T
E
L
1
3
9
4
2
2
9
6
5
1
3
9
9
2
8
9
4
2
9
8
0
5
1
5
1
3
6
7
3
Q
Q
TEL 13942296513 QQ 376315150 892498299
TEL 13942296513 QQ 376315150 892498299
http://www.xiaoyu163.com
http://www.xiaoyu163.com