1 Go/No Go Testing
This Go/No Go testing has to be carried out with an:
Antenna Coupler.
For more information on Antenna Coupler and Cable in shield box testing, refer to
1220-1336: Generic Repair Manual –electrical, section ‘Setup Go/NoGo Test’!
For part no’s on the equipment below, refer to the ‘Tools Catalogue/Matrix’!
1.1 Antenna Coupler D6603 and
D6653 no LTE
The following equipment has to be used:
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box CMU-Z11
- Rohde & Schwartz RF Coupler
- Grid Positioning Holder
RF Test Cable Flexible 1M
RF Adapter for RF Shield Box
Micro USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
Put the grid positioning holder with its reference point in
position F11 and place the phone as shown in the adjacent
picture.
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
A FEDB C G H I NMLJ K O P Q R
25
15
16
17
18
19
20
21
22
23
24
14
4
5
6
7
8
9
10
11
12
13
1
2
3
1.2 Antenna Coupler D6603
and D6653 all bands
The following equipment has to be used:
Rohde & Schwartz RF Shield Package
- Rohde & Schwartz RF Shield Box
- Rohde & Schwartz RF Coupler CMW-Z11
- Grid Positioning Holder
RF Test Cable Flexible 1M
RF Adapter for RF Shield Box
Nano USIM Card, instrument specific
GSM-850/900/1800/1900
WCDMA-850/900/1700/1900/2100
LTE-BAND 1/2/3/4/5/7/8/13/17/20/28/40
Put the grid positioning holder with its reference point in
position K13 and place the phone as shown in the adjacent
picture.