Soyal AR-1203P Series User manual

ELECTRIC BOLT LOCKS
AR-1203PSERIES
(Fail-Secure)(Power to open)
INSTALLATION INSTRUCTIONS
AR-1203P Ver.01-090807 Patent No. M 329084
Patent No. M 375750
RoHS

I. Order Information ....................................... 1
II. Specifications ........................................... 1
III. Wiring Diagram .......................................... 1
IV. Contents
.................................................. 1
V. Assembly materials ..................................... 1
VI. Power input setting
A. 12VDC input setting ................................. 2
B. 24VDC input setting ................................. 2
VII. Auto relocking timer setting ........................... 2
VIII. Indicators-LED and BUZZER ......................... 2
IX. System functions ........................................ 2
X. Installation Diagram
A. Electric Bolt locks body ............................ 2
B. Strike plate ........................................... 3
C. Dimension ............................................ 4
Contents

AR-1203P Installation Manual
SOYAL
Technology Co., Ltd.
www.soyal.com
I. Order Information
∨ 1. Whole alloy housing ∨ 7. Auto-detective logical
∨ 2. Dual Voltage: 12V / 24VDC(By 4-pin jumper) ∨8. Lock status sensor output (LSS)
∨ 3.Timer Setting: 0, 3, 6, 9 sec. for door locking ∨9. Door position status output (DSS)
∨ 4. Bicolor indicators: Dual LED ×10. Warning buzzer
∨ 5. Exit Switch Input: No, momentary contact × 11. Connect Bicolor
∨ 6. Latch off mode: press exit switch will hold × 12. With Mortice Lock Cylinder
Note:a. Latch off mode (If connected with latch type of exit switch, the bolt lock will be as N.O. without
activated till switch off.)
b. Connect Bicolor (Capability to extend the bicolor indicator by external indicators about 50cm)
II. Specifications
Item Contents Remarks
Power Input and Tolerance 12VDC 24VDC Stable PSU recommended
Pull in 1.20A 0.68A Changeable by power input and higher outer temp.Current
Draw Holding 0.22A 0.16A Changeable by power input and higher outer temp.
Surface Temperature < 40 ℃ Room Temp. 25 ℃
DSS Max.3W; Max.30VDC;Max.0.2A COM,NO,NC
LSS Max.30VDC;Max1A COM,NO,NC
III. Wiring diagram
Red : V
Black : V
Gray : No
Green : No
Browm : Nc
Power input
White : Nc
Blue : COM
Max
Door Closed
1.0A
Max
0.2A
()
Door Open
()
Bolt unlock
()
Bolt locked
()
Yellow : Exit switch
V+ (+12/+24VDC)
Exit Switch
V- (GND)
DSS
(Door Status Sensor)
LSS
(Lock Status Sensor)
Red (22AWG)
Black (22AWG)
One close to Black (22AWG)
One close to Yellow (26AWG)
COM-Blue (26AWG)
NO-Gray (26AWG) Door Closed
NC-White (26AWG) Door Open
COM-Blue (26AWG)
NO-Green (26AWG) Bolt unlock
NC-Brown (26AWG) Bolt locked
WIRING DIAGRAM
※ Caution:Please make sure the “+” and “-” wires are connected well and correctly before you apply a power source to
the lock; Warning, Reverse polarity will make a short circuit and void products warranty.
IV. Contents
Decorative Plate x 1
Lock body x1 Wire harness x 1
Striker plate x 1 MTG.TAB x 4M5-8L x8
MLC-U-Bracket x1 M5-30L x1
WD-Face Plate x 1
R4
R4
R3
R3
CTSK
6× 10
A
C
R4
R4
R3
R3 A
C
CTSK
M5
A : 195
×
27.4 mm B : 155
×
27.4 mm C :202
×
34 mm
B
B
6× 10
M5
R3
R3
R3
R3
ACD
A : 105 ×27.4 mm C : 19 - DEEP 20 mm
B : 102.55
×
25.4 mm
B
6× 10 M5 M5 6× 10
CTSK CTSK
D
D : 12 or 13 - DEEP 12 mm
Template-L x 1 Template-S x 1
V. Assembly materials (From Order)
MLC-Key MLC-Cover
Mortice Lock Cylinder
WD-U-BRACKET
-1 -

AR-1203P Installation Manual
SOYAL
Technology Co., Ltd.
www.soyal.com
VI. Power input setting
※ Caution:Please DO NOT connects the incorrect voltage to lock; otherwise, this will void products warranty.
VII. Auto relocking timer setting: (0/3/6/9 sec.)
VIII. Indicators-LED and BUZZER identification as following chart:
Indicators LED BUZZER
Waiting for locking Red LED lights up None
Door locking time delay Green LED flashes once per second None
Detecting lock Red LED flashes once per second None
Locked well Green LED flashes once every two seconds 2 beeps per seconds
Fail to lock Red LED flashes once per second for 10 seconds 1 beep per second for 10 seconds
Keeping locking Red LED flashes once every two seconds for 30 seconds 1 beep every 2 seconds for 30 seconds
Forced entry (Alarm) Green and Red LED's flash alternately every 0.5 sec. for 30 seconds Keeps beeping for 30 seconds
Remote Release(Exit Switch) Red LED flashes once per second for 3 seconds 1 beep per second
IX. System functions : By logical program systems to control the bolt lock; It has auto-detective functions
including bolt fixed position, door locking time delay, locked well and forced entry
(alarm)and remote release (exit switch). (*)-See “I. Order Information”
1. Standby (Power on the system when door is open): If you close the door, the system will receive an induction and the time delay (0/3/6/9 sec.) will
start to count, and then the auto-detective function will execute the following movements:-
a. However, the period of time delay, if door is opened, the bolt will automatically retract and the systems will return to standby.
b. After a time delay (0/3/6/9 sec.), if door is closed, the bolt will automatically extend into the “Detecting lock” and execute the following functions.
c. After “Detecting lock” (or system received an induction of “Locked well”-(*)), the bolt will automatically extend and the lock will be held.
(*)d. After “Detecting lock”, if the bolt is out and not in the right position-“Fail to lock”, the users can see bicolor indicators or listen to the “warning
buzzer” and push the door in the right position, the bolt will automatically extend and the lock will be held.
(*)e. After “Fail to lock”, the bolt will enter into “Keeping locking” mode and re-lock every 30 seconds, the users can see bicolor indicators or listen to
the “warning buzzer” and push the door in the right position, the bolt will automatically extend and the lock will be held.
2. Unlock (In locking, push the exit-switch) - “Remote Release”: The bolt will automatically retract, after 3 seconds, if the door is closed, the time delay
(0/3/6/9 sec.) will reset and count and then execute the following functions.
(*)3. Forced entry (Alarm): Indicates an error status or forced entry, the system can alarm bell given (30 seconds).
X. Installation Diagram:
12
34
1
3
4
5
7
6
8
2
A. Electic Bolt lock body
A. 12VDC input setting:
Jumper setting as shown on below:
PIN-1 and PIN-2 closed
PIN-3 and PIN-4 closed 1234
B. 24VDC input setting:
Jumper setting as shown on below:
PIN-2 and PIN-3 closed 1234
(Exit switch time delay)
ON
12
0 sec.
12 12 12
0 sec.
3 sec.
3 sec.
6 sec.
6 sec.
9 sec.
9 sec.
ON ON ON
(Door locking time delay)
※ Caution:You need to set power off (or power
disconnect) while setting the auto
relocking timer.
-2 -

AR-1203P Installation Manual
SOYAL
Technology Co., Ltd.
www.soyal.com
1. Template-L: Paste up on the doorframe surface before making a mortise cutout.
(Template-L: Place-D is a lock body)
2. Fig.1: The reference diagram of installation_1 (Typical-End view)
(Suitable for Door crack width > 3.0 mm)
3. Fig.2: The reference diagram of installation_2 (Decorative plate-End view)
(Suitable for Door crack width > 1.5 mm)
4. Fig.3: The reference diagram of installation_3 (Wood doorframe-Dimensions)
(Suitable for Door crack width > 1.5 mm)
3
7
8
2
6
4
5
1
1
2
3
4
B. Striker plate
Fig. 3
Tem-L
2.5
35
38.1(1-1/2")
1.5
44.45(1-3/4")
35(1-3/8")
Fig. 1
25.4
R4
R4
R3
R3
CTSK
6× 10
A
C
R4
R4
R3
R3 A
C
CTSK
M5
A : 195 ×27.4 mm B : 155 ×27.4 mm C :202 ×34 mm
B
B
6× 10
M5
D
1
38.1(1-1/2")
44.45(1-3/4")
35(1-3/8")
Fig. 2
25.4
Decorative plate
36.5
Fig. 5
Tem-F
R3
R3
R3
R3
ACD
A : 105 ×27.4 mm C : 19 - DEEP 20 mm
B : 102.55 ×25.4 mm
B
6× 10 M5 M5 6× 10
CTSK CTSK
D : 12 or 13 - DEEP 12 mm
-3 -
20
15
13
19
25.4
3
105
Fig. 4

AR-1203P Installation Manual
SOYAL
Technology Co., Ltd.
www.soyal.com
1. Tem-F: Paste up on the door-side surface before
making a mortise cutout.
(Tem-F: Place-B is a strike-plate)
2. Fig.4: The reference diagram of installation_4
(Wood door-Dimensions)
3. Fig.5: The reference diagram of installation_5
(Suitable for Metal door)
4. Fig.6: The reference diagram of installation_6
(Suitable for Wood door)
5. Fig.7: The reference diagram of installation_7
(Suitable for Heavy duty door)
C. Dimension
180
33
35
153
(9-1/4")234.95
193
29 (3-1/4")82.55
102.55
27.475 27.475
200
1.5
137.5
27.475
10 10
2.5
Bolt 16mm deep 16mm(5/8")
Cover(Eaves)
200Lx32Wx1.5T mm Face plate
193Lx25.4Wx2T mm
Strike plate
102.55Lx 25.4Wx2T mm
MTG.TAB
MTG.TAB MTG.TAB
MTG.TAB
-4 -
Bolt Ø16 mm Bolt Depth 16mm (5/8”) Lock Body 150L×25.4W×33D mm
Cover(Eaves) 200L×32W×1.5T mm Face plate 193L×25.4W×2T mm Striker plate 102.55L×25.4W×2T mm
Decorative plate 210L×44W×0.5T mm (Assembly materials)
Fig. 6
Fig. 7
Table of contents
Other Soyal Lock manuals
Popular Lock manuals by other brands

QiLocks
QiLocks PL707 Product guide

COMPX
COMPX SW20-1138MC Dimensional drawing

BEST ACCESS SYSTEMS
BEST ACCESS SYSTEMS Keypad EZ Remote Unlock installation instructions

CAMDEN
CAMDEN CX-DE1200 Maintenance manual

DS Produkte
DS Produkte VEG36035 instructions

Lock Control
Lock Control BL-200 installation instructions

Roto
Roto Safe Installation, maintenance and operation instructions

Targus
Targus Universal Security DEFCON Cable Lock user guide

Viro
Viro 4259 Installation & use

LOCKEY USA
LOCKEY USA SUMO GL2 installation instructions

Kaba
Kaba Simplex 1000 Series installation instructions

Kaba Mauer
Kaba Mauer 82021 Code-Combi K Operational instructions