LK-1201B SETTING
1. Operation Delay time
You could set up “Operation Delay time” by the Switch Device at the
bottom of LK-1201B directly. For example, if you set time to be 3 seconds,
when lock sensor dedicated the door status is close, it will auto re-lock in 3
seconds.
2. Wiring
Operation Delay time setting
0 Sec. 3 Sec. 6 Sec. 9 Sec.
Color Red Black Yellow Blue White Gray Purple Brown
Function
DC 12V+ GND Push
Button
(connect
Black)
COM N.O. N.C. COM N.O.
3. LED Indicators
Normal Status Indicator Unusual Status Indicator
LED status Description LED status Description
Red Door opened. Red light
flashing Door closed but lock not be
locked.
Green Door closed.
Green light
flashing Door closed but lock core not
yet. (equal to DIP switch
delay time)
Orange
light
flashing
If someone moves lock core
after door closed, alarm will
occur.
www.soyal.hu