SL150 ANALOG INTERFACE—
JB4 25 PIN MALE D CONNECTOR
PAGE 2 OF 2
DIMENSIONS: in.[mm]
PIN SIGNAL PARAMETERS
1 Power Supply Common Signal Ground
2 External Inhibit Ground Inhibit, Open HV ON
3 External Interlock +15Vdc @ open, ≤5mA @ closed
4 External Interlock Return Connect to pin 3 to enable supply
5 Current Monitor 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
6 Voltage Monitor 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
7 +10Vdc Reference +10Vdc @ 1mA, maximum
8 Remote Current Program Input 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
9 Local Current Program Output Multi-turn front panel pot for local control capability
10 Remote Voltage Program Input 0 to 10Vdc 0 to 100% rated voltage, Zout 10kΩ
11 Local Voltage Program Output Multi-turn front panel pot for local control capability
12 EFR (Common) External Fault Relay (Optional)
13
EFR (Normally Open) External Fault Relay (Optional)
14 Local HV OFF OUT +15Vdc @ open, <25mA @ closed, connect to
HV OFF for front panel operation
15 HV OFF Connect to HV OFF OUT for front panel operation
16 Remote HV ON +15Vdc @ 10mA maximum HV OFF
17 Remote HV OFF Indicator 0 HV ON, +15Vdc @ 10mA maximum HV OFF
18 Remote HV ON Indicator 0 HV OFF, +15Vdc @ 10mA maximum HV ON
19 Remote Voltage Mode Open collector 50Vdc @ 10mA maximum, ON Active
20 Remote Current Mode Open collector 50Vdc @ 10mA maximum, ON Active
21 Remote Power Mode Open collector 50Vdc @ 10mA maximum, ON Active
22 Power Supply Fault Open collector, 50Vdc @ 10mA maximum
23 +15Vdc Output +15Vdc @ 100mA, maximum
24 Power Supply Ground Signal Ground
25 Shield Return Chassis Ground
Operating Temperature:
0 to 40°C operating
Storage Temperature:
-40 to +85°C storage
Humidity:
20% to 85%, non-condensing
Input Line Connector:
3 conductor 12 AWG 6 ft (1.83m) cable, permanently attached
Output Connector:
A detachable 10 ft (3.05m) shielded HV cable is provided
Cooling:
Forced Air
Dimensions:
8.75”H x 19”W x 22”D rack mount.
(22.23cm x 48.26cm x 55.88cm)
Weight:
89 pounds (40.4kg)
Regulatory Approvals:
Compliant to 2004/108/EC, the EMC Directive
and 2006/95/EC, the Low Voltage Directive.
Specify “P” for positive polarity or “N” for negative polarity, and PN = reversible as
illustrated below.
Sample Model Number: SL150P1200/BFP/LL(20)
Where SL = power supply series, 150 = maximum output voltage in kV,
P = positive output polarity, 1200 = maximum output power (watts), BFP = Blank
Front Panel, LL(20) = 20 foot HV cable.
SPELLMAN HIGH VOLTAGE ELECT ONICS CO PO ATION
SL150kV
1200W
POWER SUPPLY
Corporate Headquarters
Hauppauge, New York USA
+1-631-630-3000 FAX: +1-631-435-1620
e-ma l: sales@spellmanhv.com
www.spellmanhv.com 128062-001 EV. F
Spellman H gh Voltage s an ISO 9001:2008 and ISO 14001:2004 reg stered company
For locat ons worldw de