EnglishDeutsch
 logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Spirax Sarco
  6. •
  7. Measuring Instrument
  8. •
  9. Spirax Sarco Flowin 2 User manual

Spirax Sarco Flowin 2 User manual

Other Spirax Sarco Measuring Instrument manuals

Spirax Sarco MTI10 Insertion User manual

Spirax Sarco

Spirax Sarco MTI10 Insertion User manual

Spirax Sarco R1C User manual

Spirax Sarco

Spirax Sarco R1C User manual

Spirax Sarco CP32 User manual

Spirax Sarco

Spirax Sarco CP32 User manual

Spirax Sarco IFTGS14 User manual

Spirax Sarco

Spirax Sarco IFTGS14 User manual

Spirax Sarco STAPs User manual

Spirax Sarco

Spirax Sarco STAPs User manual

Spirax Sarco ILVA20 User manual

Spirax Sarco

Spirax Sarco ILVA20 User manual

Spirax Sarco Colima Visco User manual

Spirax Sarco

Spirax Sarco Colima Visco User manual

Spirax Sarco TVA Series User manual

Spirax Sarco

Spirax Sarco TVA Series User manual

Spirax Sarco VLM30 User manual

Spirax Sarco

Spirax Sarco VLM30 User manual

Spirax Sarco STAPs User manual

Spirax Sarco

Spirax Sarco STAPs User manual

Spirax Sarco B850-W User manual

Spirax Sarco

Spirax Sarco B850-W User manual

Spirax Sarco MTL10 Inline User manual

Spirax Sarco

Spirax Sarco MTL10 Inline User manual

Spirax Sarco CP42 Technical specifications

Spirax Sarco

Spirax Sarco CP42 Technical specifications

Spirax Sarco ILVA20 User manual

Spirax Sarco

Spirax Sarco ILVA20 User manual

Spirax Sarco RIM20 User manual

Spirax Sarco

Spirax Sarco RIM20 User manual

Spirax Sarco DIVA User manual

Spirax Sarco

Spirax Sarco DIVA User manual

Spirax Sarco ELM Assembly instructions

Spirax Sarco

Spirax Sarco ELM Assembly instructions

Spirax Sarco UTM20 Series User manual

Spirax Sarco

Spirax Sarco UTM20 Series User manual

Spirax Sarco 2000 Series User manual

Spirax Sarco

Spirax Sarco 2000 Series User manual

Spirax Sarco RIM10 Series User manual

Spirax Sarco

Spirax Sarco RIM10 Series User manual

Spirax Sarco Colima Visco User manual

Spirax Sarco

Spirax Sarco Colima Visco User manual

Popular Measuring Instrument manuals by other brands

Suaoki D40 user manual

Suaoki

Suaoki D40 user manual

Elster BK-G1.6 operating instructions

Elster

Elster BK-G1.6 operating instructions

Endress+Hauser Deltabar FMD71 technical information

Endress+Hauser

Endress+Hauser Deltabar FMD71 technical information

Duratool D03128 manual

Duratool

Duratool D03128 manual

Vega VEGAPULS 65 Quick setup guide

Vega

Vega VEGAPULS 65 Quick setup guide

Tonghui TH2618B Operation manual

Tonghui

Tonghui TH2618B Operation manual

Tenmars TM-801 user manual

Tenmars

Tenmars TM-801 user manual

MSR 145 user manual

MSR

MSR 145 user manual

TPS WP-82 manual

TPS

TPS WP-82 manual

PCB Piezotronics 003C30 Installation and operating manual

PCB Piezotronics

PCB Piezotronics 003C30 Installation and operating manual

Tenma 72-10465 manual

Tenma

Tenma 72-10465 manual

Endress+Hauser Proline Promag 50 Brief operating instructions

Endress+Hauser

Endress+Hauser Proline Promag 50 Brief operating instructions

Siemens SITRANS F Coriolis FCT030 Function manual

Siemens

Siemens SITRANS F Coriolis FCT030 Function manual

KLINGER CMF V Series instruction manual

KLINGER

KLINGER CMF V Series instruction manual

Keysight M8290A Getting started guide

Keysight

Keysight M8290A Getting started guide

Acterna MS1400 Operation manual

Acterna

Acterna MS1400 Operation manual

R&S ZPH manual

R&S

R&S ZPH manual

Datacolor ColorReader DC10-2 user guide

Datacolor

Datacolor ColorReader DC10-2 user guide

https://manuals.online logo
https://manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2026 Manuals.Online. All Rights Reserved.

IM-P330-74 MI Issue 1 1
© Copyright 2009
Printed in the UK
Flowin 2
Natural Gas Flowmeter
Essential Installation Guide
IM-P330-74
MI Issue 1
3309851/1
This document must be read in conjunction with IM-P330-73.
Warning
To avoid the risk of injury to personnel or damage to plant or equipment, the safety
information and technical data in the Installation and Maintenance Instructions
(IM-P330-73) should be read and assessed before attempting any installation work.
Caution
To avoid the risk of damage or loss of accuracy, the installation and commissioning
guidelines in the IM-P330-73 should be read and understood.
Essential installation guidelines
The flowmeter may be installed in a horizontal or vertical pipeline, with flow in any direction.
The preferred orientation for a Flowin 2 natural gas flowmeter is in a horizontal pipeline, with
the flowmeter display facing either upwards or downwards as illustrated in Figure 1.
Before powering up the Flowin 2 for the first time, complete the following checklist:
1. Are all required connections made?
(a) Loop?
(b) Pulse? (if required)
(c) Grounding to earth of RF braiding at the Flowin end (only) of the loop and pulse cables?
(d) Flange earth connections?
2. Are all the connections secure?
3. Is the polarity of all connections correct?
4. Check that the earth resistance is in accordance with the technical data in IM-P330-73.
5. Ensure there is no possibility of a short circuit occurring when the PCB housing is refitted.
6. Refit the PCB housing to the flowmeter body in the orientation desired before ‘powering
up’ the flowmeter.
Fig. 1
Caution: Maximum permissible flange bolt tightening torque is 160 N m
Filter 250 micron
Downstream distance
Check valve
3'D'
Location of
flowmeter data label
Upstream distance
6'D'
D = Nominal bore of the pipe
Location of cast flow
arrow
IM-P330-74 MI Issue 1
2
Please note: This document must be read in conjunction with IM-P330-73
Caution – The Flowin end of all shielded cables must be grounded to the earth points provided,
as described in Section 3 of the Information and Maintenance Instructions (IM-P330-73),
otherwise the EMC performance of the Flowin 2 will be impaired, possibly resulting in flowmeter
damage or loss of accuracy.
The Flowin 2 must be earthed to the installation pipework, using the braided cables, shake-
proof washers, and the hexagon screws supplied.
Recommended specification of loop power supply and pulse output cables
The loop power supply and pulse output cables must be: 7-strand, screened, twisted pair
with a cross sectional area of 0.5 mm2. The screen must be earthed at the Flowin end of the
cable only. The maximum cable length must not be greater than 300 m, but in practice is
governed by the number of loop devices, cable capacitance and total network resistance.
EIA 232 (RS232)
Communication port
(RJ11 socket)
Remote NPN input
(maximum 28 V)
Fig. 2
Remote PNP input
(maximum 28 V)
OR
Loop
powered
4 – 20 mA
display unit
or chart
recorder
9 - 28 Vdc
+
-
R
R
230 V
50 Hz
+
-
1
2
3
4
5
Power
0 Volts
Fuse
1 A
Power
0 Volts
R  10 K 
OR
M750 display
unit with
4 - 20 mA active
input (supplying
current loop)
N
L
Pulse Loop
+ - +-