Spirent Landslide EDGE E10 User manual

P/N 71-008573 REV A
Installation Guide
Spirent Landslide Test
System
October 2018
®

Spirent Communications, Inc.
27349 Agoura Road
Calabasas, CA 91301
USA
Copyright
© 2018 Spirent Communications, Inc. All Rights Reserved.
All of the company names and/or brand names and/or product names referred to in this document, in particular, the
name “Spirent” and its logo device, are either registered trademarks or trademarks of Spirent plc and its subsidiaries,
pending registration in accordance with relevant national laws. All other registered trademarks or trademarks are the
property of their respective owners. The information contained in this document is subject to change without notice
and does not represent a commitment on the part of Spirent Communications. The information in this document is
believed to be accurate and reliable, however, Spirent Communications assumes no responsibility or liability for any
errors or inaccuracies that may appear in the document.
Limited Warranty
Spirent Communications, Inc. (“Spirent”) warrants that its Products will conform to the description on the face of
order, that it will convey good title thereto, and that the Product will be delivered free from any lawful security interest
or other lien or encumbrance.
Spirent further warrants to Customer that hardware which it supplies and the tangible media on which it supplies
software will be free from significant defects in materials and workmanship for a period of twelve (12) months, except
as otherwise noted, from the date of delivery (the “Hardware Warranty Period”), under normal use and conditions.
To the extent the Product is or contains software (“Software”), Spirent also warrants that, if properly used by Customer
in accordance with the Software License Agreement, the Software which it supplies will operate in material
conformity with the specifications supplied by Spirent for such Software for a period of ninety (90) days from the date
of delivery (the “Software Warranty Period”). The “Product Warranty Period” shall mean the Hardware Warranty
Period or the Software Warranty Period, as applicable. Spirent does not warrant that the functions contained in the
Software will meet a specific requirement or that the operation will be uninterrupted or error free. Spirent shall have no
warranty obligations whatsoever with respect to any Software which has been modified in any manner by Customer or
any third party.
Defective Products and Software under warranty shall be, at Spirent's discretion, repaired or replaced or a credit issued
to Customer's account for an amount equal to the price paid for such Product provided that: (a) such Product is
returned to Spirent after first obtaining a return authorization number and shipping instructions, freight prepaid, to
Spirent's location in the United States; (b) Customer provides a written explanation of the defect or Software failure
claimed by Customer; and (c) the claimed defect actually exists and was not caused by neglect, accident, misuse,
improper installation, improper repair, fire, flood, lightning, power surges, earthquake, or alteration. Spirent will ship
repaired Products to Customer, freight prepaid, based on reasonable best efforts after the receipt of defective Products.
Except as otherwise stated, any claim on account of defective materials or for any other cause whatsoever will
conclusively be deemed waived by Customer unless written notice thereof is given to Spirent within the Warranty
Period. Spirent reserves the right to change the warranty and service policy set forth above at any time, after
reasonable notice and without liability to Customer.
TO THE EXTENT PERMITTED BY APPLICABLE LAW, ALL IMPLIED WARRANTIES, INCLUDING BUT
NOT LIMITED TO IMPLIED WARRANTIES OF MERCHANTABILITY, NONINFRINGEMENT AND FITNESS
FOR A PARTICULAR PURPOSE, ARE HEREBY EXCLUDED, AND THE LIABILITY OF SPIRENT, IF ANY,
FOR DAMAGE RELATING TO ANY ALLEGEDLY DEFECTIVE PRODUCT SHALL BE LIMITED TO THE
ACTUAL PRICE PAID BY THE CUSTOMER FOR SUCH PRODUCT. THE PROVISIONS SET FORTH ABOVE
STATE SPIRENT'S ENTIRE RESPONSIBILITY AND CUSTOMER'S SOLE AND EXCLUSIVE REMEDY WITH
RESPECT TO ANY BREACH OF ANY WARRANTY.

Spirent Communications License Agreement
BY ACCESSING OR EXECUTING THE SOFTWARE, YOU AGREE TO BE BOUND BY THE
TERMS OF THIS AGREEMENT.
Spirent Communications, Inc. (“Spirent”) and its licensors provide the software contained on the media
in the package and/or as part of the equipment supplied by Spirent and any modifications, enhancements
to and/or replacements of such Software supplied to you by Spirent including, without limitation,
firmware (collectively “Software”), together with the associated documentation (the “Documentation”)
and license their use on the terms and conditions set forth herein.
LICENSE: Spirent grants you a a limited, nontransferable and nonexclusive license, without the right to
sublicense, to use the Software, in object code form only, and Documentation only for your internal use.
Spirent retains title and ownership rights of the Software and Documentation and no rights are granted to
you other than to use the Software and Documentation on the terms expressly set forth in this Agreement.
You acknowledge that the underlying structure, sequence, organization, and source code of the Software
are valuable trade secrets of Spirent and/or licensors and you agree as follows:
You, your employees, and/or agents are required to protect the confidentiality of the Software and
Documentation. You may not (i) distribute or otherwise make the Software and Documentation available
to any third party; (ii) use the Software or Documentation to provide services to third parties without the
prior written consent of Spirent; (iii) assign, sublicense, or transfer this license; (iv) decompile, reverse
engineer, modify, or copy the Software or Documentation for any purpose, except you may make one
copy of the Software supplied electronically or on disks and/or diskettes for backup purposes in support
of your use of the Software on a single controller; (v) remove or overprint any copyright, trademark, or
confidentiality notices appearing in the Software or Documentation; or (vi) use the Software on a
timesharing or service bureau basis. You agree to reproduce all copyright, trademark, or confidentiality
notices on the backup copies of the Software.
Software applications are licensed to specific serial number controllers or modules. Upgrade versions of
the Software may be used only on controllers or modules, by serial number, for which the original
Software was purchased.
TERM: This license is effective until terminated as set forth herein. You may terminate this license at
any time by deleting the Software from your computer libraries and archives and returning all copies of
the Software and Documentation, including backup copies, to Spirent.
LIMITED WARRANTY: During the first ninety (90) days after delivery of the Software to you (the
“Warranty Period”), as evidenced by a copy of your invoice or proof of purchase, Spirent warrants that
the Software will perform substantially in accordance with the Documentation and that the media on
which the Software is furnished will be free from defects in materials and workmanship under normal
use. Spirent does not warrant that the functions contained in the Software will meet a specific
requirement or that the operation will be uninterrupted or error free.
EXCEPT AS PROVIDED HEREIN, THE SOFTWARE AND DOCUMENTATION ARE PROVIDED
WITHOUT WARRANTY OF ANY KIND, EITHER EXPRESS OR IMPLIED, INCLUDING, BUT
NOT LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY,
NONINFRINGEMENT, AND FITNESS FOR A PARTICULAR PURPOSE. SOME STATES DO NOT
ALLOW THE EXCLUSIONS OF IMPLIED WARRANTIES, SO THE ABOVE EXCLUSION MAY
NOT APPLY TO YOU.
LIMITATION OF LIABILITY: Spirent’s and its licensors’ entire liability under this Agreement is to
use commercially reasonable efforts to correct any failure of the Software, of which it is given written
notice by you during the Warranty Period, to perform substantially in accordance with the
Documentation, provided such failure can be recreated by Spirent. Spirent shall replace media not
meeting Spirent’s Limited Warranty and which is returned to Spirent with a copy of your proof of
purchase. If Spirent is unable to correct such failure, or unable to deliver replacement media which is free
from defects in materials or workmanship, you may terminate this Agreement in accordance with the
section entitled “Term” above and the license fee paid by you will be refunded.

IN NO EVENT WILL SPIRENT OR ITS LICENSORS BE LIABLE TO YOU OR ANY THIRD
PARTY FOR ANY DAMAGES, INCLUDING ANY LOST PROFITS, LOST SAVINGS, OR OTHER
INCIDENTAL OR CONSEQUENTIAL DAMAGES ARISING OUT OF THE USE OR INABILITY
TO USE THE SOFTWARE EVEN IF SPIRENT HAS BEEN ADVISED OF THE POSSIBILITY OF
SUCH DAMAGES. SPIRENT’S AND ITS LICENSORS’ LIABILITY, IF ANY, FOR DAMAGES
RELATING TO ANY ALLEGEDLY DEFECTIVE SOFTWARE SHALL BE LIMITED TO THE
ACTUAL FEE PAID BY YOU FOR SUCH SOFTWARE.
GENERAL: (1) This Agreement will be governed by the internal laws of the State of New York without
regard to the U.N. Convention on Contracts for the International Sale of Goods. (2) You agree to comply
with the United States Export Administration Act of 1979, as amended, and the United States Export
Administration Regulations of the United States Department of Commerce with regard to the exportation
of the Software and Documentation. (3) This Agreement is the entire agreement between you and Spirent
and supersedes any prior or contemporaneous agreements or communications, oral or written, relating to
the subject matter of this Agreement.
COMMERCIAL COMPUTER SOFTWARE RIGHTS LEGEND
Use, modification, reproduction, release, display, or disclosure by the Government of the Commercial
Computer Software or Commercial Computer Software Documentation contained in this package is
subject to the restrictions of the accompanying Spirent license agreement in accordance with Federal
regulations at 48.C.F.R. Section 12.212 and Subsection 227.7202-3.

Spirent Landslide Test System Installation Guide |5
Contents
About this Guide . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 7
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Related Documentation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 8
Acronyms . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 9
Shipment Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Standard Landslide System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
EDGE E10 System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
Release Notes. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 10
How to Contact Us. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 11
Chapter 1: System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 14
Landslide Architecture Terminology . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Client Requirements. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 15
Chapter 2: Initial Installation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 17
Standard Landslide System Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
System Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 18
Landslide Manager Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Landslide Test Server Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 19
Management Port Configuration . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 20
Chapter 3: Landslide E10 System Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 29
Landslide E10 Test System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
Deployment . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 30
System Configuration Overview . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 32
Federal Communication Commission Interference Statement . . . . . . . . . . . . . . . . . . . . . . . . 33
Chapter 4: Installing U1 OTA Modules on the Landslide E10 . . . . . . . . . . . . 35
Introduction . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Before You Begin . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
Package Contents . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 36
SIM Card Insertion and Removal . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 37
Installing and Removing the Modules . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 38
Connecting the USB Cables and Antennas. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 40
Connecting the Antennas . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 42
Chapter 5: Getting Started. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45
Logging in to the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 46
Adding Test Servers to the System . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47

Contents
6|Spirent Landslide Test System Installation Guide
Installing the Tcl API. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Securing the System. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Default Passwords. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 47
Appendix A: Landslide Test Server NIC Configurations . . . . . . . . . . . . . . . . . . 49
General . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Supported NICs and IPSec Cards . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 50
Supported NIC Configurations and Port Names . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 52

About this Guide
Introduction
8|Spirent Landslide Test System Installation Guide
Introduction
The purpose of this document is to provide the System Administrator with the
information necessary to install and activate the Landslide Performance Test System.
This document assumes that the Landslide software is properly installed and licensed
on the Landslide appliance.
Related Documentation
Additional documentation for the software used with the system is provided in an online
Help format. The Help documentation can be accessed from the system’s home page or
through the Help menu in the application window. See “Logging in to the System” on
page 46 for instructions on loading the home page after installation is complete.
To install and use the Landslide Tcl API, refer to the Getting Started > How To Test >
Working with Tcl API > Using the Tcl API online Help topic.
Additional information on using Landslide can be found in the following related
resources. Refer to the latest version of the Landslide software Release Notes for the most
current information regarding Landslide documentation.
These documents are provided in PDF format:
•Spirent Landslide Test System Installation Guide (this manual)
•Landslide Test Server NIC Configurations (appendix to this manual)
•Landslide Virtual Machine Installation Instructions
•Landslide Tcl API Object and Perform Function Reference
•Landslide RESTful Programmer’s Reference
Spirent Customer Service Center / Knowledge Base
The Spirent Customer Service Center (https://support.spirent.com) includes useful tools
such as a powerful Knowledge Base. The Knowledge Base offers an easy-to-use browse
mode, along with an intelligent search that offers quick answers to your network analysis
and measurement questions. Log in with your CSC user ID and password to access
content that is available only to customers - user manuals, help files, release notes, and
more.
Information about Spirent Communications and its products and services is available on
the company website at https://www.spirent.com.

About this Guide
Acronyms
Spirent Landslide Test System Installation Guide |9
Acronyms
The following acronyms are used in this manual.
Acronym Meaning
C100 C100 Series Test Server
C50 C50 Series System and Add-on Test Server
DUT Device Under Test
E10 SAS Landslide E10 Stand-alone Test System
E10 TS Landslide E10 Test Server
L-C100-M4-TS Landslide C100 M4 Test Server
L-C100-S4-MGR Landslide C100 S4 Manager
L-C50-S4-SYS Landslide C50 S4 System Appliance
L-C50-S4-TS Landslide C50 S4 Add-on Test Server
Manager Test Administration Server Appliance
SPT-C100-M4-TS Same as L-C100-M4-TS
SUT System Under Test
TAS Test Administration Server
TS Test Server
vTAS Virtual Test Administration Server
vTS Virtual Test Server

About this Guide
Shipment Contents
10 |Spirent Landslide Test System Installation Guide
Shipment Contents
Standard Landslide System
Check your system to ensure that you have the following items:
For C100 Test Systems
•1 - Landslide C100 Manager with power cord
•1 (or more) - Landslide C100 Test Server(s) with power cord (a minimum of one Test
Server is required for all systems; you may have more than one depending on the
configuration you purchased).
•0 or more optional E10 Test Server(s)
•0 or more optional Virtual Test Server(s)
For C50 Test Systems
•1 - Landslide C50 Test System appliance with power cord
•0 or 1 - Landslide C50 Add-on Test Server (only one stand-alone, Add-on Test Server
can be added to a C50 Test System).
EDGE E10 System
Check your system to ensure that you have the following items:
•1 - Landslide EDGE E10 appliance
•1 - Power supply and cord
•3 - Dual-band (2.4 and 5.8GHz) antennas
•1 - Ethernet cable
Release Notes
Release Notes contain the latest technical information that may not be included in the
product’s user documentation.
Hardware and software system requirements are described in the Release Notes.
Important: It is highly recommended that you read all Release Notes before you install
or use this product.

About this Guide
How to Contact Us
Spirent Landslide Test System Installation Guide |11
How to Contact Us
To obtain technical support for any Spirent Communications product, please contact our
Support Services department using any of the following methods:
Americas
E-mail: support@spirent.com
Web: https://support.spirent.com
Toll Free: +1 800-SPIRENT (+1 800-774-7368) (North America)
Phone: +1 818-676-2616
Hours: Monday through Friday, 05:00 to 17:00, Pacific Time
Europe, Middle East, Africa
E-mail: support@spirent.com
Web: https://support.spirent.com
Phone: +33 (1) 6137 2270 (France)
Phone: +44 1803 546333 (UK)
Hours: Monday through Thursday, 09:00 to 18:00, Friday, 09:00 to 17:00, Paris Time
Asia Pacific
E-mail: support@spirent.com
Web: https://support.spirent.com
Phone: +86 (400) 810-9529 (toll-free mainland China only)
Phone: +86 (10) 8233 0033 (China)
Hours: Monday through Friday, 09:00 to 18:00, Beijing Time
Company Address
Spirent Communications, Inc.
27349 Agoura Road
Calabasas, CA 91301
USA

12 |Spirent Landslide Test System Installation Guide

Spirent Landslide Test System Installation Guide |13
Chapter 1
System Overview
The Landslide Performance Test System is a comprehensive test system developed for
testing wireless packet data core network elements. For a detailed description of system
functionality, refer to the online Help documentation.
In this chapter...
• Deployment . . . . 14
• Landslide Architecture Terminology . . . . 15
• Client Requirements . . . . 15

System Overview
Deployment
14 |Spirent Landslide Test System Installation Guide
Deployment
Landslide C100 Test System
The Landslide C100 Test System is deployed on Spirent Landslide C100 rack-mounted
server platforms. A typical lab deployment configuration is shown in Figure 1-1. The
Landslide Manager hosts the Test Administration Server (TAS) software, which serves the
user interface through the LAN, acts as the data repository, and controls overall system
operations. The Landslide Test Server hosts the Test Server software, which performs the
test operations. The Landslides communicate with the Systems Under Test (SUTs) via an
Ethernet LAN or a direct Ethernet connection.
A single Landslide system supports from one (1) to thirty-two (32) Test Servers. Users
connect to the Landslide test system and access the TAS from a Java Web Client.
Figure 1-1. Typical Lab Deployment

System Overview
Landslide Architecture Terminology
Spirent Landslide Test System Installation Guide |15
Landslide C50 Test System
The Landslide C50 Test System provides an economical solution for customers who
require the complete functionality of a full Landslide Test System, but at smaller scale and
lower data performance.
The Landslide C50 Test System consists of an integrated TAS Manager and Test Server
residing on a single, rack-mountable SPT-C50 appliance. Users can add a single stand-
alone, Add-on Test Server for additional scale and performance. In all other respects, the
C50 Test System is the same as the C100 Test System.
Landslide Architecture Terminology
For a complete description of the Landslide architecture and all associated terminology,
refer to the online Help documentation. Select Getting Started > System Overview >
Architecture.
Client Requirements
Hardware and software system requirements are described in the Release Notes.
Important: It is highly recommended that you read all Release Notes before you install
or use this product.

16 |Spirent Landslide Test System Installation Guide

Initial Installation
Standard Landslide System Configuration
18 |Spirent Landslide Test System Installation Guide
Standard Landslide System Configuration
Follow the instructions in this section to configure a standard system consisting of a
Landslide Manager and one or more Landslide Test Server(s).
System Configuration Overview
The general steps involved in configuring a Landslide test system are outlined below.
1Install and power up the Landslide C100 Manager and Test Server(s) or the C50
combined Manager and Test Server.
2Provide an IP address on your management network for the Manager and for each
Test Server.
Notes: • For C50 test systems, a second management network IP address is required
only when the Add-on Test Server is part of the system configuration.
•The management network should be different from the test network that
contains the devices/systems under test.
3Configure the Manager’s management port by following the steps in
“Landslide Manager Configuration” on page 19.
4Configure each Test Server by following the steps in
“Landslide Test Server Configuration” on page 19.
5After you have configured your Test Servers, continue with the instructions in
Chapter 5, “Getting Started.”

Initial Installation
Standard Landslide System Configuration
Spirent Landslide Test System Installation Guide |19
Landslide Manager Configuration
The Landslide Manager's management port is located on the front panel of the appliance
and is labeled Mgmt Port (Figure 2-1). The management port's logical name is eth0, and
it handles communications with client PCs and the Landslide Test Servers.
•Ports labeled 1, 2, and 4 are not used
•The manager does not include the test ports in slots 1 through 6
Note: The C50-based Test System, with combined Manager and Test Server, may include
test ports in slots 1 through 6.
Figure 2-1. Landslide Front Panel - Management Port
Follow this procedure to configure the Landslide Manager for LAN communication.
To configure a Landslide Manager:
1Establish a telnet session with the Landslide Manager and configure the management
port (see “Management Port Configuration” on page 20).
2Remove the standard Ethernet cable from the management port.
3Connect the Landslide Manager to your LAN via a standard Ethernet connection from
the management port to a router or switch.
Landslide Test Server Configuration
All Ethernet ports are accessible from the front of the Landslide Test Server. The
management port is in the same location as on the Landslide Manager and is labeled
Mgmt and logically named eth0, as on the manager. Ports 1, 2, and 4 are not used. The
remaining interfaces are located to the right of the management port and are referred to as
Test Ports. The management port handles communications with the Landslide Manager,
and the test ports handle communications with Systems Under Test (SUTs) and other
devices involved in a test.
The location of the management port is shown in Figure 2-1.
Note: The names assigned to test ports depend on the number and type of Ethernet NICs
installed in the test server. Supported NIC configurations and associated port naming are
provided in Appendix A. As viewed from the front, chassis slot numbers increase from left
to right. The leftmost slot is number 1.

Initial Installation
Management Port Configuration
20 |Spirent Landslide Test System Installation Guide
Configuring a Landslide Test Server
Follow this procedure to configure the management port for each Landslide TS. After the
platforms for the system, including the Landslide Manager, have been configured,
continue with the instructions in Chapter 5, “Getting Started.”
To configure a Landslide Test Server:
1Establish a telnet session with the Landslide TS and configure the management port
(see “Management Port Configuration”).
2Remove the standard Ethernet cable from the management port.
3Connect the Landslide to your LAN via a standard Ethernet connection from the
management port to a router or switch.
Connect the test ports to the test network via a router or directly to the SUT.
Management Port Configuration
Refer to the applicable procedure if you are using IPv4 or IPv6 addressing on the
management network.
•Refer to page 21 for management port configuration using IPv4 addressing
•Refer to page 24 for management port configuration using IPv6 addressing
Note: The procedures in this section use the following abbreviations:
•TAS – Landslide Manager / Test Administration Server
•TS – Landslide Test Server
•TAS+TS – A combination system comprised of both a Landslide Manager
and Landslide Test Server running on the same server
Follow the procedure in this section to power up a Landslide platform for the first time.
This initial configuration procedure designates and configures the management port for
each platform. The default test port configuration can be modified using the Test Server
Configuration window within the application (see Managing Your System > Test Server
> Managing Your Test Servers in the Help documentation).
The management port is dedicated to communications with the Landslide Manager
(Landslide Test Server platform) or with the user's client PC (Landslide Manager
platform), and is not used for testing on these platforms. The default name and default
address of the management port is eth0 and 192.168.0.100, respectively. Use a default
mask of 255.255.255.0.
This manual suits for next models
1
Table of contents
Other Spirent Test Equipment manuals
Popular Test Equipment manuals by other brands

Test Equipment Depot
Test Equipment Depot Cable Prowler TCB300 user manual

Lakeland
Lakeland PTK220 Usage instructions

Gossen MetraWatt
Gossen MetraWatt METRALINE RCD CHECK operating instructions

Multimetrix
Multimetrix ERT 201 user manual

Wise
Wise TSW800TP Operation manual

Teledyne Lecroy
Teledyne Lecroy WaveRunner/MDA 8000HD Series Operator's manual