manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SSET
  6. •
  7. Transducer
  8. •
  9. SSET CE-F01-MS-0.5 Series User manual

SSET CE-F01-MS-0.5 Series User manual

http://www.ce-transducer.com 3rdFloor,building1, Zaimaoindustrialpark, Baoji road, Bantian, Longgangdistrict,
sales@ce-transducer.com ShenzhenCity, ChinaPostcode:518049
FrequencySignal Transducer
Istructions
CE-F01-**MS*-0.5
1 Overview
Thisproductisanarbitrarywaveformofthefrequencysignal
detectionisolationtransducer.Usingtheprincipleof
photoelectric isolationcanconvert theinputfrequencysignalinto
alinearoutputof0~5V,0~20mA,4~20mAand otherstandard
signals. Theinputfrequencysignalcanbeasinewave,square
waveand zero-crossingwave,anditsamplitudecanreach
1000Vpp. Thisproductisdouble-isolation,theinputandoutput
areisolatedfromthepowersupply.Productinstallationissimple,
canbewidelyusedincommunications,power,railway,industrial
controlandotherfields.
Features:
ØWithwaveformshapingfunction,canbearbitrary
waveforminputmeasurement;
ØAmplitudevariation canbeas lowas 5%;
ØFrequencymeasurementup to10KHz;
ØGood stabilityand highprecision.
2 Case Style
Figure1, DC powersupply(MS2)productappearance
Figure2,220Vpowersupply(MS2)productappearance
3 PartNumber
Figure3ProductSelectionGuide
4 Specifications
Testconditions:auxiliarypower: +12 V, roomtemperature:25 C.
Inputrange:frequency:0-50Hz~10KHZ, Amplitude:5-500V;
Output: 0-5V,0-20mA, 1-5V,4-20mA, 0-10V;
Powersupply:DC 12V,15V,24V,AC/DC 85V 265V;
Accuracy:0.5;
Loadcapacity: ≥2KΩ(voltageoutput); ≤250Ω(currentoutput);
Temperaturedrift: <500ppm/ C;
Isolationvoltage:DC 2500V
Response time: ≤200mS; (Frequency<100Hzresponse time
<800mS)
Ratedpowerconsumption:<0.5W
Outputripple:<10mV
Frequencyrange:0Hz 10kHz
SurgeImmunity:Input4KV(L-N /2Ω/integratedwave),
powersupply/outputport 2KV(L-N /40Ω/integratedwave);
Impulse immunity: ±2KV input/powerport,analogI/Oport ±
1KV;
Inputoverloadcapacity:continuousoverload:120%;short-term
overload:2times theratedvoltageinputvaluefor1second;
Operatingtemperature:-10 C~+60 C;
Storageconditions:-40 C~+70 C.
5 ConnectionsDiagram
Figure4, wiringdiagramofCE-F01-3*MS2/CE-F01-8*MS2
Figure5, wiringdiagramofCE-F01-4*MS2/CE-F01-5*MS2
http://www.ce-transducer.com 3rdFloor,building1, Zaimaoindustrialpark, Baoji road, Bantian, Longgangdistrict,
sales@ce-transducer.com ShenzhenCity, ChinaPostcode:518049
Figure6, wiringdiagramofCE-F01-*9MS3
6Installations
Rail mountingdimensions:35mm;screwsinstallation size:
73X26.8mm;as showninFigure7(inmm).
Figure7:Mountingdimensions
7 Product sService
1Installation
1.1DIN railinstallationmethod:
①Fixthetransduceronthesideofthecardslotandhookon
themountingrail;
②Pull thespringpindown;
③Clipthetransducermounton themountingrail;
④Release thespringpinand clipthetransmitteron the
mountingrail.
1.2Screwmountingmethod:
①4mmdiameterholeinthefixedplateaccordingtothescrew
holepositionshowninFig.5;
②Use thescrew Φ3toinsert intoholeandsecureit.
2Producthas beenaccuratelysetaccordingtothe"product
standard".Applypowerafterdeterminethecorrectwiring.
3Themaximumwirediameteroftheterminalblockis2mm
(16-26AWG).Removethe4mm~5mminsulationlayerfromthe
end ofthemountingwireand insert it intotheterminalblock,then
tightenthescrew.
4Productsupplypowerrequires theisolationvoltage ≥2000VAC,
ACripple<10mV. Multipletransducerscanshareacommon setof
powersupplies,butthepowercircuit cannolongerbeusedto
driverelaysand othercanproduce spikes intheload,inorderto
avoidinterference signaltransmission tothetransducer.
5 Thetransducersoutput0-20mA(or4-20mA),theRLstandardis ≤
250Ω,and0-5VvoltageoutputRLstandardis ≥2KΩ,canguarantee
theoutputaccuracyand linearityovertheentireratedinputrange.
8 Example ofproductaccuracy levelverification
1Accordingtothedefinitionofthetransducerterminalstoconnect
thetestcircuitas shown.
Figure6, accuracytestwiringdiagramofvoltageorcurrentoutput
Note: Thevoltageoutputismeasuredwithavoltmeterand the
currentoutputismeasuredwithanIometer.
2Thetestshallbecarriedoutunderthefollowingenvironmental
conditions:
◆Powersupply:nominal ±5%, ripple ≤10mV;
◆Ambienttemperature:25 C ±5 C;
Relativehumidity:RH (45 ~80)%;
◆Theaccuracyofthesignalsource and measurement
instrumentis0.05%above.
3Powerpreheat2min;
4Assumingthetransmitterinputfrequencyrangeis0-10KHz,he
outputis0-5VDC,givenanyinputvalueFinthetransducerrange,
thetheoreticaloutputvalue(Vz)ofthetransduceriscalculatedas
follows:
Vz=(F÷10KHz)×5V
Iftheoutputis4-20mA, thenIz=4+F÷10KHz×16mA;
Iftheoutputis0-20mA, thenIz=F÷10KHz×20mA;
5ThemonitoringtablemeasurestheDC voltageoutputvalueVoor
thecurrentoutputvalueIo.
│Vo-Vz│≤25mVisnormal, orexcessive(0-5Voutput, 0.5);
│Io-Iz│≤80uAisnormal, orexcessive(4-20mAoutput,0.5);
│Io-Iz│≤100uAisnormal, orexcessive(0-20mAoutput,0.5);
6Repeatthe5operation,theresultingpointvalueis
│Vo-Vz│≤25mVor │Io-Iz│≤80uA(100uA),thetransduceraccuracy
levelisqualified.
Note: please consult withourcompanyfortheverification method
detailedofothertechnicalindicators.
9 Notes
1Please payattention tothewiringon productlabelandtheoutput
http://www.ce-transducer.com 3rdFloor,building1, Zaimaoindustrialpark, Baoji road, Bantian, Longgangdistrict,
sales@ce-transducer.com ShenzhenCity, ChinaPostcode:518049
contactcapacity.
2Transducerfortheintegratedstructure,notremovable,and
shouldavoidcollisionandfall.
3Thetransducersareusedinenvironmentswithstrong
electromagneticinterference.Standardprecautionsuchas
shieldingtheinputand /oroutputlines shouldbeobserved.All
lines shouldbeas shortas possible.Ifagroupoftransducersare
mountedtogether,keepaspace morethan10mm betweenadjacent
units.
4Theinputvaluegivenonthetransducerlabelreferstotherms
valueoftheac signal.
5Onlyuse theeffectiveterminalofthetransducer.Theother
terminalsmaybeconnectedwiththeinternalcircuitofthe
transducer, andcan’tbeusedforotherpurposes.
6Transducerhas acertainanti-lightningability,butwhenthe
transducerinputandoutputfeedersexposedtoextremebad
environments, mustbetakenlightningprotection measures.
7Don’tdamageormodifytheproductlabelandlogo.Don’t
disassembleormodifythetransducer,otherwise thecompanywill
nolongerprovidetheproduct"three guarantees"(replacement,
returns, repair)services.
8Thetransducersuse flame-retardantABSplasticshellpackage.
whichlimit temperatureis+75 ℃.Theshell will bedeformed
withhigh-temperaturebaking,andwill affectproductperformance.
Donotuse orsavetheproductneartheheatsource.Donotbake
theproductinahigh-temperatureoven.
9Whenmeasuringthevoltageorcurrentwiththemulti meterpen,
please screwtheterminalscrewintheend,otherwise it maynot
measurethevoltageorcurrentoutputvalue.

Other SSET Transducer manuals

SSET CE-C Series User manual

SSET

SSET CE-C Series User manual

SSET CE-C02-S3-0.5 Series User manual

SSET

SSET CE-C02-S3-0.5 Series User manual

SSET CE-IJ03 SK-0.5 Series User manual

SSET

SSET CE-IJ03 SK-0.5 Series User manual

SSET CE-VJ31A -MSK- 0.5 Series User manual

SSET

SSET CE-VJ31A -MSK- 0.5 Series User manual

SSET CE-VJ41 -9MSK-0.5 Series User manual

SSET

SSET CE-VJ41 -9MSK-0.5 Series User manual

Popular Transducer manuals by other brands

Iskra iMT440 user manual

Iskra

Iskra iMT440 user manual

Nexus NX2 installation manual

Nexus

Nexus NX2 installation manual

Humminbird XTH 9 DB 74 P manual

Humminbird

Humminbird XTH 9 DB 74 P manual

Simrad ES333-7C -  REV A installation manual

Simrad

Simrad ES333-7C - REV A installation manual

Redback C 8856A operating instructions

Redback

Redback C 8856A operating instructions

Humminbird Bronze Thru-Hull Transducer manual

Humminbird

Humminbird Bronze Thru-Hull Transducer manual

HP 5501A Operating and service manual

HP

HP 5501A Operating and service manual

Balluff BTL5-S1 Series Condensed guide

Balluff

Balluff BTL5-S1 Series Condensed guide

Balluff BTL5-S M A Series user guide

Balluff

Balluff BTL5-S M A Series user guide

SKF CMSS 785 Series user manual

SKF

SKF CMSS 785 Series user manual

Agilent Technologies IMG-300 instruction manual

Agilent Technologies

Agilent Technologies IMG-300 instruction manual

CCS WattNode Pulse WNB-3Y-208-P Installation and operation manual

CCS

CCS WattNode Pulse WNB-3Y-208-P Installation and operation manual

WIKA F2301 operating instructions

WIKA

WIKA F2301 operating instructions

Lumel VTR06 user manual

Lumel

Lumel VTR06 user manual

GHM Greisinger GRMU2000 MP operating manual

GHM Greisinger

GHM Greisinger GRMU2000 MP operating manual

novotechnik TMI Series manual

novotechnik

novotechnik TMI Series manual

Thyracont VSC43MV operating instructions

Thyracont

Thyracont VSC43MV operating instructions

Setra Systems GCT225 installation guide

Setra Systems

Setra Systems GCT225 installation guide

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.