Stabila LD 500 User manual

Oper ting instructions
GB
Laser Distancer LD 500

789
654
12
0
3
1
2
3
5
7
9
15
14
4
6
8
13
12
11
10
2
1
8
7
3
4
5
6
1
7
65
4
3
2
1
11
2
3
1
2
3
1
2
max.

789
654
12
0
3
1
2
3
5
7
9
15
14
4
6
8
13
12
11
10
2
1
8
7
3
4
5
6
1
7
65
4
3
2
1
11
2
3
1
2
3
1
2
max.

1
Stabila LD 500 Safety Instructions
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
User Manual
English
Congratulations on the purchase of your Stabila LD 500.
Carefully read the Safety Instructions and the User
Manual before using this product.
The person responsible for the instrument must
ensure that all users understand these directions and adhere to them.
Contents
Safety Instructions...............................................................................................1
Start-up....................................................................................................................4
Menu functions.....................................................................................................6
Operation ...............................................................................................................8
Measuring................................................................................................................9
Functions.................................................................................................................9
Appendix.............................................................................................................. 14
Safety Instructions
Symbols used
The symbols used in the Safety Instructions have the following meanings:
WARNING:
Indicates a potentially hazardous situation or an unintended use
which, if not avoided, will result in death or serious injury.
CAUTION:
Indicates a potentially hazardous situation or an unintended use
which, if not avoided, may result in minor injury and/or in appreciable
material, financial and environmental damage.
)Important paragraphs which must be adhered to in practice as
they enable the product to be used in a technically correct and efficient
manner.
Use of the instrument
Permitted use
•Measuringdistances
• Computing functions, e. g. areas and volumes
• Measuring tilts
Prohibited use
• Using the instrument without instruction
• Using outside the stated limits
• Deactivation of safety systems and removal of explanatory and hazard
labels
• Opening of the equipment by using tools (screwdrivers, etc.), as far as
not specifically permitted for certain cases
• Carrying out modification or conversion of the product
• Use of accessories from other manufacturers without the express
approval of Stabila.

2
Safety Instructions Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
• Deliberate or irresponsible behaviour on scaffolding, when using
ladders, when measuring near machines which are running, or near
parts of machines or installations which are unprotected
• Aiming directly into the sun
• Deliberate dazzling of third parties; also in the dark
• Inadequate safeguards at the surveying site (e.g. when measuring on
roads, construction sites, etc.)
Limits of use
)See section “Technical Data“.
The Stabila LD 500 is designed for use in areas permanently habitable by
humans, do not use the product in explosion hazardous areas or in aggres-
sive environments.
Areas of responsibility
Responsibilities of the manufacturer of the original equipment
Stabila Messgeräte, D-76855 Annweiler am Trifels (for short
Stabila):
Stabila is responsible for supplying the product, including the User Manual
and original accessories, in a completely safe condition.
Responsibilities of the manufacturer of non-Stabila acces-
sories:
)The manufacturers of non-Stabila accessories for the
Stabila LD 500 are responsible for developing, implementing and commu-
nicating safety concepts for their products. They are also responsible for
the effectiviness of these safety concepts in combination with the Stabila
equipment.
Responsibilities of the person in charge of the instrument:
WARNING
The person responsible for the instrument must ensure that the
equipment is used in accordance with the instructions. This person is also
accountable for the deployment of personnel and for their training and for
the safety of the equipment when in use.
The person in charge of the instrument has the following duties:
• To understand the safety instructions on the product and the instruc-
tions in the User Manual.
• To be familiar with local safety regulations relating to accident preven-
tion.
• To inform Stabila immediately if the equipment becomes unsafe.
Hazards in use
CAUTION:
Watch out for erroneous distance measurements if the instrument
is defective or if it has been dropped or has been misused or modified.
Precautions:
Carry out periodic test measurements. Particularly after the instrument
has been subject to abnormal use, and before, during and after important
measurements.
Make sure the Stabila LD 500 optics are kept clean and that there is no
mechanical damage to the bumpers.
CAUTION:
In using the instrument for distance measurements or for positio-
ning moving objects (e.g. cranes, building equipment, platforms, etc.) unfo-
reseen events may cause erroneous measurements.
Precautions:
Only use this product as a measuring sensor, not as a control device. Your
system must be configured and operated in such a way, that in case of an
erroneous measurement, malfunction of the device or power failure due
to installed safety measures (e.g. safety limit switch), it is assured that no
damage will occur.

3
Stabila LD 500 Safety Instructions
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
WARNING:
Flat batteries must not be disposed of with household waste. Care
for the environment and take them tothe collection points provided in
accordance with national or local regulations.
The product must not be disposed of with household waste.
Dispose of the product appropriately in accordance with the
national regulations in force in your country.
Always prevent access to the product by unauthorised
personnel.
Electromagnetic Compatibility (EMC)
The term "electromagnetic compatibility" is taken to mean the capability of
the product to function smoothly in an environment where electroma-
gnetic radiation and electrostatic discharges are present, and without
causing electromagnetic interference to other equipment.
WARNING:
The Stabila LD 500 conforms to the most stringent requirements of
the relevant standards and regulations. Yet, the possibility of it causing
interference in other devices cannot be totally excluded.
CAUTION:
Never attempt to repair the product yourself. In case of damage,
contact the local dealership.
Laser classification
Integrated distancemeter
The Stabila LD 500 produces a visible laser beam which emerges from the
front of the instrument.
It is a Class 2 laser product in accordance with:
• IEC60825-1 : 2007 "Radiation safety of laser products"
Laser Class 2 products:
Do not stare into the laser beam or direct it towards other people unne-
cessarily. Eye protection is normally afforded by aversion responses inclu-
ding the blink reflex.
WARNING:
Looking directly into the beam with optical aids (e.g. binoculars,
telescopes) can be hazardous.
Precautions:
Do not look directly into the beam with optical aids.
CAUTION:
Looking into the laser beam may be hazardous to the eyes.
Precautions:
Do not look into the laser beam. Make sure the laser is aimed above or
below eye level. (particularly with fixed installations, in machines, etc.)

4
Start-up Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Labelling
Position of the product label see last page!
Start-up
Inserting/replacing batteries
See figure {A}
1 Remove battery compartment lid.
2 Insert batteries, observing correct polarity.
3 Close the battery compartment again. Replace the batteries when the
symbol flashes permanently in the display.
)Remove the batteries before any long period of non-use
to avoid the danger of corrosion.
)Use alkaline batteries or rechargeable batteries only.
Changing the reference point (multifunctional
endpiece)
See figure {B}
The instrument can be adapted for the following measuring situations:
• For measurements from an edge, fold out the positioning bracket until
it first locks in place. See figure {C}.
• For measurements from a corner, open the positioning bracket until
it locks in place, then push the positioning bracket lightly to the right
to fold it out fully. See figure {D}.
A built-in sensor automatically detects the orientation of the positioning
bracket and adjusts the zero point of the instrument accordingly.
Laser Radiation
Do not stare into the beam
Laser class 2
acc. IEC 60825-1:2007
Maximum radiant power: <1mW
Emitted wavelength: 620-690nm
Beam divergence 0.16 x 0.6 mrad
Pulse duration: 1 x 10 -9 s

5
Stabila LD 500 Start-up
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Keypad
See figure {E}:
1On/measuring button
2Menu/Equal button
3Plus (+) button
4Digital pointfinder - button
5Stake out - button
6Area / volume button
7Trapezium button
8Tilt measurement - button
9Clear/Off button
10 Storage/Memory button
11 Reference button
12 Timer button
13 Indirect measurement (Pythagoras) button
14 Minus (-) button
15 Multiplication / Division - button
Display in normal mode
See drawing {F.1}.
The graphics screen of the measurement window is split into different
areas. Top left is the brightest field, which contains the currently selected
measuring program. Just to the right appears the program submenu, which
shows the measuring programs that can be selected by pressing the same
key the required number of times.
The measurement field contains the individual measurements of the
measuring program with reference to a series of separate distance measu-
rements. Three lines are provided for this. A horizontal line separates the
measurement field and the result bar from one another. A red triangle indi-
cates whether the selected measuring program has a detailed display avai-
lable.
1Program selection with measurement instructions
2 Program selection submenu
3 Level
4Timer
5 Measurement field
6 Result bar
7 Detailed display
8 Status bar with (Laser ON, Reference plane, Display Long range mode,
Offset, Plus / Minus, Battery status)
Display in "digital pointfinder" mode
Digital pointfinder (4x zoom)
The device has an integral digital pointfinder, which shows the target
directly on the display. The displayed crosshairs allow precise measure-
ments to be made even though the laser beam is not visible. See drawing
{F.2}
The integral coloured digital pointfinder is a great help outdoors and can
be used in every function. Longer distances and precise measurements on
detailed surfaces can even be accomplished in bright sunlight without any
problem.
The 4x zoom allows the image to be magnified to suit the user's require-
ments.
Press the key to activate the function. Press the key again to
operate in a 1x, 2x or up to 4x zoom view.
The brightness of the camera can be adjusted through 5 levels using the

6
Menu functions Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
key or the key.
)Parallax errors occur when the digital pointfinder is used on close
targets, the laser dot may appear displaced in the crosshair. In this case you
should rely on the actual laser dot for targeting the object.
See drawing {F.2}
1 Zoom step (1x, 2x, 4x)
2Timer
3 Level (in °)
4Crosshairs
5 Inclination angle
6 Distance tracking value
7 Image
Menu functions
Settings
Various device settings can be made in the menu. A vertical list shows each
entry. In this menu the selection field (cursor) remains stationary and the
list moves in a vertical direction. Starting from the centre of the list, the
priority of list entries starts at the top and fans out clockwise. See drawing
{G}.
The menu contains following items:
1Timer
2 Laser continuous measurement mode
3 Display illumination
4 Digital Pointfinder image in black/white
5 Level in status field (in °)
6 Units of measurement (distance)
7Lo
ngrangemode
8 Units of measurement (angle)
9 Beep
10 Calibrate tilt sensor
11 Offset
12 Tripod
13 Reset
Navigation in the menu
The menu allows settings to be customized for a particular user or appli-
cation.
General description
Press and hold the key to enter the Setup menu.
By pressing the or keys, navigate through the main menu
items in the menu.
Press the key briefly to enter the submenu of the selected main
menu item.
By pressing the or keys you can make the alterations in the
submenu.
Press and hold the key to accept the settings.
Pressing the button for longer in the menu allows you to quit the
settings function without saving.
Timer ( )
The time delay (default value) can be changed using the or
buttons. Pressing the button for longer increases the rate of change of the
values. When you reach the desired time delay value, confirm it with the
button.

7
Stabila LD 500 Menu functions
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Laser continuous ( )
The laser is continuously switched on. Every press of the button trig-
gers a distance measurement.
If the laser is in continuous operation mode, the device switches off auto-
matically after 15 minutes.
Digital Pointfinder image black / white ( )
The display in pointfinder mode can be changed to black / white.
Setting the unit for distance measurements
The following units can be set:
Setting the unit for tilt measurements
The following units can be set for tilt measurements:
Calibrate the tilt sensor ( )
You can calibrate the tilt sensor in the device. Calibration requires two
measurements on a level surface.
Select calibration mode in the menu .
1 Carry out a first measurement on a level surface. The device
confirms the measurement with .
2 Rotate the device horizontally through 180° .
3 Press the key and confirm that the device was rotated through
180°.
4 Press the key and take the second measurement. The device
confirms the measurement with .
The tilt sensor is calibrated.
Measuring with the tripod ( )
The reference point may be adjusted to the tripod mount if the user
requires a measurement from the actual mounting grommit versus the
front or back of the Stabila LD 500. To do this select the symbol in
this menu item. You can switch the reference on the tripod on or off. The
setting can be seen on the display .
Distance Area Volume
1.1 0.000 m 0.000 m² 0.000 m³
1.2 0.0000 m 0.000 m² 0.000 m³
1.3 0.00 m 0.000 m² 0.000 m³
1.4 0.00 ft 0.00 ft² 0.00 ft³
1.5 0'00'' 1/32 0.00 ft² 0.00 ft³
1.6 0'00'' 1/16 0.00 ft² 0.00 ft³
1.7 0'00'' 1/80.00 ft² 0.00 ft³
1.8 0'00'' 1/40.00 ft² 0.00 ft³
1.9 0.0 in 0.00 ft² 0.00 ft³
1.10 0 1/32 in 0.00 ft² 0.00 ft³
1.11 0 1/16 in 0.00 ft² 0.00 ft³
1.12 0 1/8 in 0.00 ft² 0.00 ft³
1.13 0 1/4in 0.00 ft² 0.00 ft³
1.14 0.000 yd 0.000 yd² 0.000 yd³
Units for tilt
2.1 +/- 0.0°
2.2 0.00%
2.3 mm/m
2.4 in/ft

8
Operation Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
)We recommend that measurements are initiated using the
key when using the device on a tripod in order to prevent loss of
sharpness.
The settings are reset when the device is switched off.
Reset - returning the instrument to the factory
settings ( )
The instrument has a Reset function. If you select the menu function Reset
and confirm, the device returns to the factory settings and stack and
memory are deleted.
)All customised settings and stored values are also lost.
Offset ( )
An offset adds or subtracts a specified value automatically to or from all
measurements. This function allows tolerances to be taken into account
(e.g. unfinished dimensions compared with finished dimensions). If you
selected the Offset function in the menu, you can now adjust the value
using the or the key. Pressing the key for longer increases the
rate of change of the values. When you reach the desired offset value,
confirm it with the key. The display shows the appropriate symbol
or for as long as the offset value is set.
Beep ( )
You can switch the beep on or off.
Long range Mode ( )
Unfavourable conditions (strong sunlight or a very weak reflective target
surface) may reduce the range of the device, in spite of this the long range
mode allows you to take measurements over longer distances. The use of
a tripod and measurement initiation by pressing the key are recom-
mended when measurements over 30m are made over longer time periods
in these conditions. (For details see Technical specifications)
)The settings are reset when the device is switched off.
Level in status field ( )
The Level (in °) in status field can be switched on or off.
Display illumination ( )
The brightness of the display has six levels of adjustment. Step 6 is the
brightest and step 1 is the darkest setting.
Operation
Switching on and off
Switches on the instrument and laser. The display shows the
battery symbol until the next button is pressed.
Pressing this button for longer switches the instrument off.
The instrument switches off automatically after six minutes of
inactivity.
CLEAR button
The last action is cancelled. While making area or volume measure-
ments, each single measurement can be deleted and remeasured in series.
Reference setting
The default reference setting is from the rear of the instrument.

9
Stabila LD 500 Measuring
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Press this button to take the next measurement from the front edge
. A special beep sounds whenever the reference setting is changed.
After a measurement the reference returns automatically to the default
setting (rear reference). See figure {H}.
Press this button for longer the front reference is set permanently.
Press this button, the rear reference is set again.
Measuring
Single distance measurement
Press to activate the laser. Press again to trigger the distance measu-
rement.
The result is displayed immediately.
Minimum/maximum measurement
This function allows the user to measure the minimum or maximum
distance from a fixed measuring point. It can also be used as determine
spacings. See figure {I}.
It is commonly used to measure room diagonals (maximum values) or hori-
zontal distances (minimum values).
Press and hold down this button until you hear a beep. Then slowly
sweep the laser back and forth and up and down over the desired target
point - (e.g. into the corner of a room).
Press to stop continuous measurement. The values for maximum and
minimum distances are shown in the display as well as the last measured
value in the summary line.
Functions
Overview of the program icons
Measuring program Icon Measurement
1 - 2 - 3 Detail display
1 - 2 - 3
Simple distance measure-
ment
Area measurement
Volume measurement
Trapezoid measurement
1 (using three distances)
Trapezoid measurement
2 (using two distances and
one angle)
Pythagorean calculation 1
Pythagorean calculation 2
Pythagorean calculation 3
Inclination measurement
Direct horizontal distance
Triangular area measure-
ment
Staking out function

10
Functions Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Addition / subtraction
Distance measuring.
The next measurement is added to the previous one.
The next measurement is subtracted from the previous one.
This process can be repeated as required.
Press this button and the result is then always shown in the summary
line with the previous value in the second line.
The last step is cancelled.
Multiplication
Measure distance.
Press this button once. The symbol " * " appears in the display.
The keypad switches to numerical entry mode. Enter a dimensionless
number and confirm your entry with . The value entered is multiplied
by the measurement value.
Division
Measure distance.
Press this button twice. The symbol " / " appears in the display.
The keypad switches to numerical entry mode. Enter a dimensionless
number and confirm your entry with . The value entered is divided by
the measurement value.
Area
Press once. The symbol appears in the display.
Press this button to take the first length measurement (e.g.
length).
Press it again to take the second length measurement (e.g.
width).
The result is shown in the summary row.
Press and hold the key to display the perimeter .
Volume
Press this button twice. The symbol appears in the display.
Press this button to take the first length measurement (e.g.
length).
Press this button to take the second length measurement (e.g.
width).
Press this button to take the third length measurement (e.g.
height).
The result is shown in the summary row.
Press and hold the button to display additional room information
such as ceiling/floor area , surface area of the walls , circumfe-
rence .
Trapezium measurement 1
See drawing {J}
Press the key once. The symbol is displayed.
Press the key and take the first length measurement (e.g.
height 1).
Press the key again and take the second length measurement
(e.g. width)
Press the key and take the third length measurement (e.g.
height 2).

11
Stabila LD 500 Functions
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
The result is shown in the summary row.
Press and hold the key to display additional information about the
trapezium measurement, for example inclination angle , trapezium
area .
Trapezium measurement 2
See drawing {K}.
Press the key twice. This symbol is displayed.
Press the key and take the first length measurement .
Press the key and take the second length measurement and incli-
nation angle measurement.
)The device measures inclination angles between + 45
and - 45°.
The result is shown in the summary row.
Press and hold the key to display additional information about the
trapezium measurement, for example inclination angle , trapezium
area .
Tilt measurement
)The inclination sensor measures tilts between ± 45°.
)The infocode i 160 means that the device has been set outside the
permissible limits.
)During tilt measurement the instrument should be heldwithout a
transverse tilt (max. 10°).
)If the device is tilted by more than ± 10° laterally, the display
shows infocode i 156 which means that the device has been tilted
too much.
)The units of inclination are set in the menu.
Press this button once to activate the tilt sensor. The symbol
appears in the display. The tilt is continuously shown as ° or % depending
on the setting.
Press to measure the inclination and the distance. See figure {L}.
Direct horizontal distance
Press this button
twice
and the following symbol appears in the
display .
Press this button to measure tilt and distance. The summary line
displays the result as the direct horizontal distance.
Press and
hold
the key to display additional information about the
measurement, for example the inclination angle , the measured distance
and the indirect height .
See drawing {
M
}.
Stake out function
Two different distances (a and b) can be entered into the instrument and
can then be used to mark off defined measured lengths, e.g. in the construc-
tion of wooden frames.
See figure {O}.
Entering stake out distances:
Press this button and the stake out function symbol appears in the
display .
By using and , you can adjust the values (first a and then b) to
suit the desired stake out distances. Holding the buttons down increases
the rate of change of the values.
Once the desired value (a) has been reached it can be confirmed with

12
Functions Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
the button.
Value (b) can be entered using and . The defined value (b)
is confirmed with the button.
Pressing the button starts the laser measurement. The display shows
required stake out distance in the summary line between the stake out
point (first a and then b) and the instrument (rear reference).
If the Stabila LD 500 is then moved slowly along the stake out line the
displayed distance decreases. The instrument starts to beep at a distance
of 0.1m from the next stake out point.
The arrows in the display indicate in which direction the
Stabila LD 500 needs to be moved in order to achieve the defined distance
(either a or b). As soon as the staking out point is reached, the symbol
appears in the display.
The function can be stopped at any time by pressing the button.
Indirect measurement
The instrument can calculate distances using Pythagoras’ theorem.
This procedure is helpful, if the distance to measure can not be reached
directly.
)Make sure you adhere to the prescribed sequence of measure-
ment:
• All target points must be in a horizontal or vertical plane.
• The best results are achieved when the instrument is rotated about a
fixed point (e.g. with the positioningbracket fully folded out and the
instrument placed on a wall) or the Stabila LD 500 is mounted on a
tripod.
•The minimum/maximum function can be used - see explanation in
"Measuring -> Minimum/maximum measurement". The minimum value
must be used for measurements at right angles to the target; the
maximum distance for all other measurements.
Indirect measurement - determining a distance using 2
auxilliary measurements
See figure {P}
e.g. for measuring building heights or widths. It is helpful to use a tripod
when measuring heights that require the measurement of two or three
measurements.
Press this button once, the display shows . The laser is swit-
ched on.
Aim at the upper point (1) and trigger the measurement . After
the first measurement the value is adopted. Keep the instrument as hori-
zontal as possible.
Press and hold down this button to trigger continuous measurement
, sweep the laser back and forth and up and down over the ideal target
point.
Press to stop continuous measurement (2). The result is displayed in
the summary line, the partial results in the secondary line.
Press and hold the key to display additional information about the
measurement of the angles of the triangle and .
Indirect Measurement - determining a distance using 3
measurements
See figure {Q}
Press this button twice; the display shows the following symbol
. The laser is switched on.
Aim at the upper point (1) and trigger the measurement. After the
first measurement the value is adopted. Keep the instrument as horizontal
as possible

13
Stabila LD 500 Functions
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Press and hold down this button to trigger continuous measurement
, sweep the laser up and down over the ideal target point.
Press to stop continuous measurement (2). The value is adopted. Aim
at the lower point and
press this button to trigger the measurement (3) . The result is
displayed in the summary line, the partial results in the secondary lines.
Press and hold the key to display additional information about for
example the partial distances , and the minimum distance .
Indirect measurement - determining a partial value using
3 measurements
See figure {R}
e.g. determining the height between point 1 and point 2 using three target
points.
Press this button three times ; the display shows the following
symbol . The laser is switched on.
Aim at the upper point (1).
Press this button and trigger the measurement . After the first
measurement the value is adopted.
Triggers the measurement . After the second measurement the
value is adopted.
Press and hold down this button to trigger continuous measurement
. Sweep the laser up and down over the ideal target point.
Press this button to end continuous measurement. The result is
displayed in the summary line, the partial results in the secondary lines.
Press and keep pressed the key to display additional information
about the measurement of the partial lengths and .
Triangular area
The area of a triangle can be calculated by the measurement of three sides.
See drawing {N}.
Press the key four times - the triangle symbol appears in the
display.
Press the key and measure the first side of the triangle .
Press the key and measure the second side of the triangle .
Press the key and measure the third side of the triangle .
The result is shown in the summary row.
Press and hold the key to display additional information about the
measurement, such as the angle included by the first two measure-
ments and the perimeter of the triangle.
Storage of constants / historical storage
Storage of a constant
You can store and recall a frequently used value e.g. height of a room.
Measure the desired distance, press and hold the button until the
device beeps to confirm storage.
Recalling the constant
Press twice to call up the constant and then press the button
to enter it into your calculation.
Historical storage
Press this button once and the previous 20 results (measurements
or calculated results) are shown in reverse order.
The and buttons can be used for navigation.

14
Appendix Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Press this button to use a result from the summary line for further
calculations.
Pressing the and buttons at the same time erases all the values
in historical storage.
Timer (self-triggering)
Press once briefly to set the delay time using the menu.
or
Press and hold down this button until the desired time delay is
reached (max. 60 seconds).
Once the key is released with the laser activated, the remaining seconds
until measurement (e.g. 59, 58, 57...) are displayed in a countdown. The last
5 seconds are counted down with a beep. After the last beep the measu-
rement is taken and the value is displayed.
)The timer can be used for all measurements.
Appendix
Message codes
All message codes are displayed with either or "Error". The following
errors can be corrected:
Cause Remedy
156 Transverse tilt greater than 10° Hold the instrument without
any transverse tilt
160 Main tilt direction, angle too
high (> 45°) Measure angle up to max. ± 45°
162 The calibration has not been
accomplished on a leveled
surface and the calibration value
is respecitvely within an ineli-
gible area.
Calibrate the device on an abso-
lute horizontal leveled surface.
204 Calculation error Repeat procedure
252 Temperature too high Cool down instrument
253 Temperature too low Warm up instrument
255 Receiver signal too weak,
measurement time too long,
distance > 100 m
Use target plate
256 Received signal too strong Target too reflective (use target
plate)
257 Wrong measurement, back-
ground brightness too high Darken target (measure in diffe-
rent lighting conditions)
260 Laser beam interrupted Repeat measurement
Error Cause Remedy
Error Hardware error Switch on/off the device several
times. If the symbol still appears,
then your instrument is defec-
tive. Please call your dealer for
assistance.

15
Stabila LD 500 Appendix
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Technical data
* maximum deviation occurs under unfavourable conditions such as bright sunlight or
when measuring to poorly reflecting or very rough surfaces. Measuring accuracy
between 10 m and 30 m may deteriorate to approx. ± 0.025 mm/m, for distances
above 30 m to ± 0.1 mm/m. In long range mode the maximum deviation from a
distance of 30 m increases to +/- 0.15 mm/m.
Distance measurements:
Measuring accuracy up to 10 m
(2
σ
, standard deviation) typically: ± 1.0 mm*
Power Range Technology™:
Range (use target plate from about 100 m) 0.05 m to 200 m
Smallest unit displayed 0.1 mm
Distance measurement
9
Minimum/maximum measurement, Conti-
nuous measurement
9
Area/volume calculation of room data
9
Addition / subtraction
9
Indirect measurement using
Pythagoras
9
Trapezium measurement
9
Tilt measurements:
Tilt sensor:
Accuracy
(2
σ
, standard deviation)
- to laser beam
- to the housing
± 0.3°
± 0.3°
Indirect measurement using tilt sensor
(direct horizontal distance)
9
Angle measurement using tilt sensor
(
± 45°)
9
General:
Laser class II
Laser type 635 nm, < 1 mW
Ø laser point
(at distances) 6 / 30 / 60 mm
(10 / 50 / 100 m)
Autom. laser switch-off after 3 min
Autom. instrument switch-off after 6 min
Display illumination
9
Multifunctional endpiece
9
Timer (self-triggering)
9
Save constant value
9
Historical storage 20 values
Tripod thread (Type: 1/4-20)
9
Battery life,
Type AA, 2 x 1.5V up to
5 000 measurements
Protection against splashes and dust IP 54, dust-proof,
splash-proof
Dimensions 143.5 x 55 x 30 mm
Weight (with batteries) 195 g
Temperature range:
Storage
Operation
-25°C up to +70°C
(-13°F up to +158°F)
-10°C up to +50°C
(14°F up to +122°F)

16
Appendix Stabila LD 500
D
GB
SLO
F
I
E
P
NL
N
FIN
DK
TR
CZ
PL
S
HR
H
SK
LV
LT
KOR
RUS
CHN
EST
GR
RO
Measuring conditions
Measuring range
The range is limited to 200 m.
At night or dusk and if the target is in shadow the measuring range without
target plate is increased. Use a target plate to increase the measurement
range during daylight or if the target has poor reflection properties.
Target surfaces
Measuring errors can occur when measuring toward colourless liquids (e.g.
water) or dust free glass, Styrofoam or similar semi-permeable surfaces.
Aiming at high gloss surfaces may deflect the laser beam and lead to measu-
rement errors.
Against non-reflective and dark surfaces the measuring time may increase.
Care
Do not immerse the instrument in water. Wipe off dirt with a damp, soft
cloth. Do not use aggressive cleaning agents or solutions. Handle the
instrument as you would a telescope or camera.
Warranty
Stabila provides a two-year warranty for the Stabila LD 500.
Further information can be found on the Internet at: www.stabila.de

STABILA Messgeräte
Gust v Ullrich GmbH
P.O. Box 13 40 / D-76851 Annweiler
L nd uer Str. 45 / D-76855 Annweiler
Tel.: 00 49 (0) 63 46 / 309 - 0
F x: 00 49 (0) 63 46 / 309 - 480
e-m il: info@st bil .de
www.st bil .de
Table of contents
Other Stabila Analytical Instrument manuals