Operating instructions
Additional languages www.stahl-ex.com
EN
Explosion Proof Combination Signal –
110 dB (A) / 5 Joule
Series YL60

General Information
2Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Contents
1 General Information ............................................................................................2
1.1 Manufacturer .......................................................................................................2
1.2 Information regarding the operating instructions .................................................3
1.3 Further documents ..............................................................................................3
1.4 Conformity with standards and regulations .........................................................3
2 Explanation of the symbols .................................................................................3
2.1 Symbols in these operating instructions .............................................................3
2.2 Warning notes .....................................................................................................4
2.3 Symbols on the device ........................................................................................5
3 Safety notes ........................................................................................................5
3.1 Operating instructions storage ............................................................................5
3.2 Safe use ..............................................................................................................5
3.3 Modifications and alterations ..............................................................................5
4 Function and device design ................................................................................5
4.1 Function ..............................................................................................................6
5 Technical data .....................................................................................................6
6 Transport and storage .........................................................................................8
7 Mounting and installation ....................................................................................9
7.1 Dimensions / fastening dimensions ....................................................................9
7.2 Mounting / dismounting, operating position ........................................................9
7.3 Installation .........................................................................................................16
8 Commissioning .................................................................................................16
9 Operation ..........................................................................................................17
9.1 Troubleshooting ................................................................................................17
10 Maintenance and repair ....................................................................................17
10.1 Maintenance .....................................................................................................17
10.2 Repair ...............................................................................................................18
10.3 Returning the device .........................................................................................18
11 Cleaning ............................................................................................................18
12 Disposal ............................................................................................................18
13 Accessories and Spare parts ...........................................................................19
1 General Information
1.1 Manufacturer
R. STAHL Schaltgeräte GmbH
Centre of Competence Light
Nordstr. 10
99427 Weimar
Germany
R. STAHL Schaltgeräte GmbH
Am Bahnhof 30
74638 Waldenburg
Germany
Phone:
Fax:
Internet:
E-mail:
+49 3643 4324
+49 3643 4221-76
www.stahl-ex.com
Phone:
Fax:
Internet:
E-mail:
+49 7942 943-0
+49 7942 943-4333
www.stahl-ex.com

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explanation of the symbols
3
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
1.2 Information regarding the operating instructions
ID-No.: 222936 / YL6060300020
Publication Code: 2014-10-20·BA00·III·en·00
The original instructions are the English edition.
They are legally binding in all legal affairs.
1.3 Further documents
• Data sheet
For further languages, see www.stahl-ex.com.
1.4 Conformity with standards and regulations
See certificates and EC Declaration of Conformity: www.stahl-ex.com.
The device has IECEx approval.
See IECEx homepage: http://iecex.iec.ch/
2 Explanation of the symbols
2.1 Symbols in these operating instructions
Symbol Meaning
Tips and recommendations on the use of the device
General danger
Danger due to explosive atmosphere
Danger due to energised parts

Explanation of the symbols
4222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
2.2 Warning notes
Warning notes must be observed under all circumstances, in order to minimize the risk
due to construction and operation. The warning notes have the following structure:
• Signalling word: DANGER, WARNING, CAUTION, NOTICE
• Type and source of danger/damage
• Consequences of danger
• Taking countermeasures to avoid the danger/damage
= Strobe
= Sounder
= Earth
= Sounder Stage 1
= Sounder Stage 2
= Sounder Tone
= Telephone initiate
DANGER
Danger to persons
Non-compliance with the instruction results in severe or fatal injuries to
persons.
WARNING
Danger to persons
Non-compliance with the instruction can result in severe or fatal injuries to
persons.
CAUTION
Danger to persons
Non-compliance with the instruction can result in light injuries to persons.
NOTE
Avoiding material damage
Non-compliance with the instruction can result in material damage to the device and / or
its environment.
1
2

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Safety notes
5
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
2.3 Symbols on the device
3 Safety notes
3.1 Operating instructions storage
• Read the operating instructions carefully and store them at the mounting location of
the device.
• Observe applicable documents and operating instructions of the devices to be
connected.
3.2 Safe use
• Read and observe the safety notes in these operating instructions!
• Observe characteristic values and rated operating conditions on the rating and data
plates!
• Observe additional information plates on the device!
• Use the device in accordance with its intended and approved purpose only!
• We cannot be held liable for damage caused by incorrect or unauthorized use or by
non-compliance with these operating instructions.
• Before installation and commissioning, make sure that the device is not damaged!
• Work on the device (installation, maintenance, overhaul, repair) may only be carried
out by appropriately authorized and trained personnel.
3.3 Modifications and alterations
4 Function and device design
Symbol Meaning
05594E00
CE marking according to the current applicable directive.
02198E00
According to marking, device approved for hazardous areas.
15649E00
Input
15648E00
Output
DANGER
Explosion hazard due to modifications and alterations to the device!
Non-compliance results in severe or fatal injuries.
• Do not modify or alter the device. No liability or warranty for damage
resulting from modifications and alterations.
DANGER
Explosion hazard due to improper use!
Non-compliance results in severe or fatal injuries.
• Use the device only according to the operating conditions described in
these operating instructions.

Technical data
6222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
4.1 Function
The explosion proof combination signal series YL60 is an audible and visual signal. It
provides an audible and/or visual signal intended to alert, warn or draw attention to an
event. It is designed for use in hazardous or harsh environments. In hazardous areas the
devices have explosion protection for ATEX/IECEx Zones 1 & 2 for gas and 21 & 22 for
dust. Gas groups covered are IIB & IIB + H2, dust protection for IIIC.
UL certified variants offer protection to Class I Division I Gas groups BCD,
Class II Division I Gas groups EFG.
The device is not intended for continuos use.
The life of the xenon flash tube is guaranteed for the following number of flashes:
5 Technical data
Variant Number of flashes
5 J 2 million
10 J 5 million
20 J 4 million
Explosion Protection
Global (IECEx)
Gas and dust
Europe (ATEX)
Gas and dust
IIB+H2 IECEx BAS 05.0087X
IIB IECEx BAS 05.0086X
IIB+H2, IIB IEC 60079-0: 2011 / IEC 60079-1: 2007-04 / IEC 60079-31: 2008
IIB+H2 Ex d IIB+H2 T4 Gb (Ta = -20 … +60°C)
Ex tb IIIC T135°C Db IP 66 (Ta = -20 … +60 °C)
Ex d IIB+H2 T6 Gb (Ta = -20 … +40 °C)
Ex tb IIIC T85°C Db IP 66 (Ta = -20 … +40 °C)
IIB Ex d IIB T4 Gb (Ta = -35 … +60 °C)
Ex tb IIIC T135°C Db IP 66 (Ta = -35 … +60 °C)
Ex d IIB T6 Gb (Ta = -35 … +40 °C)
Ex tb IIIC T85°C Db IP 66 (Ta = -35 … +40 °C)
IIB+H2 Baseefa02ATEX0222X
IIB Baseefa02ATEX0212X
IIB+H2, IIB EN 60079-0: 2009 / EN 60079-1: 2007 / EN 60079-31: 2009
IIB+H2 EII 2 GD Ex d IIB+H2 T4 Gb (Ta = -20 … +60 °C)
EII 2 GD Ex tb IIIC T135°C Db IP 66 (Ta = -20 … +60 °C)
EII 2 GD Ex d IIB+H2 T6 Gb (Ta = -20 … +40 °C)
EII 2 GD Ex tb IIIC T85°C Db IP 66 (Ta = -20 … +40 °C)
IIB EII 2 GD Ex d IIB T4 Gb (Ta = -35 … +60 °C)
EII 2 GD Ex tb IIIC T135°C Db IP 66 (Ta = -35 … +60 °C)
EII 2 GD Ex d IIB T6 Gb (Ta = -35 … +40 °C)
EII 2 GD Ex tb IIIC T85°C Db IP 66 (Ta = -35 … +40 °C)

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Technical data
7
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
USA and Canada (UL variants)
Gas and dust
Russia (GOST R)
Газ Marking and certification based on and line with the ATEX product.
Certifications and certificates
Certificates IECEx, ATEX, Brazil (INMETRO), India (PESO), Kazakhstan (GOST K),
Russia (GOST R), Taiwan (ITRI), USA (UL)
Technical Data
Technical data
Product weight 6 kg
Electrical data
Rated operational
voltage
24 V DC, 48 V DC, 115 V AC and 230 V AC operational parameters + or -10 %
Rated operational
current
Mechanical data
Material
Enclosure aluminium, seawater resistant
Horn ABS, flame retardant
Lens cover polycarbonate
Fixings stainless steel
Explosion Protection
IIB+H2, IIB E161818
IIB+H2, IIB SL: UL 60079-0 / UL 60079-1 / UL 1203 / UL 1638
CSA C22.2 No. 30-M1986 / CSA C22.2 No. 25-M1966 / CSA
E60079-0-7 / CSA E60079-1
IIB+H2 Class I, Div. 1, Groups B, C and D
Class I, Div. 2, Groups B, C and D
Class 1 Zone 1 AEx d IIB + H2 T4
Class 1 Zone 1 Ex d IIB + H2 T4
Operating temperature -25 ... +66 °C
Audible signal appliance public mode with supplementary
Visual signal appliance private mode
IIB Class I, Div. 1, Groups C and D
Class I, Div. 2, Groups C and D
Class 1 Zone 1 AEx d IIB T4
Class 1 Zone 1 Ex d IIB T4
Operating temperature -35 ... +66 ºC
Audible signal appliance public mode with supplementary
Visual signal appliance private mode
24 V DC 570 mA
48 V DC 435 mA
115 V AC 200 mA
230 V AC 100 mA

Transport and storage
8222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
6 Transport and storage
• Transport and store the device only in the original packaging.
• Store the device in a dry place (no condensation) and vibration-free.
• Do not drop the device.
Cable entries 2 cable entries, equipped with stopping plug (1x) and dust cap (1x) UL devices:
equipped with M20 / 1/2 ’’ adapters (2x)
Degree of protection IP66 – IEC 60529
NEMA 4X – UL 50
Operating temperature range
Variant dependant see Explosion protection
Acoustic data
Volume 110 dB(A) / 1 m
Polar diagram
Luminous characteristics
Effective candela
Flash energy 5 J
Flash rate 60 FPM
Technical Data
Horizontale plane Verticale plane
15288E00
120
15
45
75
105
135
165
15
45
75
105
135
165
V
nom
V
min
5 J
Clear 30 cd
Yellow 29 cd
Amber 17 cd
Red 9 cd
Blue 6 cd
Green 7 cd
No figures for Magenta or Opal lens

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Mounting and installation
9
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
7 Mounting and installation
7.1 Dimensions / fastening dimensions
7.2 Mounting / dismounting, operating position
• Mount the device on a flat surface suitable for its weight.
• The tone output should be directed towards the area to be covered
(see chapter
Technical Data, Polar diagram).
• Insert the cables using certified and flameproof cable glands which are suitable for the
gas group.
• Close unused entries using certified and flameproof stopping plugs.
Dimensional Drawings (All Dimensions in mm / inches) - Subject to Alterations
13977E00
DANGER
Risk of explosion!
Risk of injuries and material damage!
• Terminal sleeves are fitted, they must be gas-tight and applied with a
suitable tool.
DANGER
Explosion hazard!
Risk of injuries and material damage!
• Carefully remove or replace the components.
• Exposed joint surfaces must not be damaged and must be protected
from dust and dirt.
• Install the end flanges squarely without applying any force. Do not use
a hammer or other tools when working on the flanges and do not use the
fixing screws to pull down the flanges.
420 [16,54]
75 [2,95]
M8
145 [5,71]

Mounting and installation
10 222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
7.2.1 Installation Conditions for Electrical Connection
7.2.2 Access to the PCB
• Remove the 3 screwST 4,2 x 13
• Lift horn cover
• Remove the 4 cheese-head screws M5 x 16
• Lift sounder flange
DANGER
Explosion hazard!
Risk of injuries and material damage!
• Only use cable glands with corresponding certificate. The cable glands
must be flameproof (Ex d) and suitable for the type of cable used.
• Close unused open holes in the enclosure with flameproof stopping
plugs.
• Close unused cable glands using flameproof plugs.
• Cable glands, stopping plugs and plugs must meet the requirements of
IEC/EN 60079-14.
• Installation of the cable gland must be performed in accordance with the
manufacturer's instructions.
• Cable entry temperature may reach 70 °C.
• To ensure degree of protection IP 66, a non-hardening sealant must be
applied to the threads.
DANGER
Danger due to energised parts!
Risk of death or severe injuries!
• Before opening and dismounting the device, disconnect it from the
power supply.
• Secure the device against unauthorized switching.
15256E00
1 Screws ST 4,2 x 13
2 Horn cover
3 Cheese-head screws M5 x 16
4 Sounder flange
5PCB
6Enclosure
1
2
3
4
5
6

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Mounting and installation
11
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
• Disconnect pressure unit from PCB (see Electrical Connection, Key Components)
• Lift PCB to expose terminals for connection (see Electrical Connection,
Wiring Diagrams for details)
7.2.3 Reassembly of Enclosure
• With wires terminated, carefully lower PCB back into position.
• Reconnect pressure unit to PCB and place sounder flange back into position.
Take care not to trap connecting wire in the joint. The flange must be inserted squarely
into the main body, do not use force.
• Replace cheese head screws M5 x 16 (see information box below) with 3Nm torque.
• Fit horn cover into position.
• Replace screws ST 4,2 x 13 with 0,4 Nm torque.
• Correct reassembly of the unit is required to ensure ingress protection
to IP 66. Cheese-head screws (see chapter Acess to the PCB, position
3) are supplied with Nyltite washers. Before reassembly inspect Nyltite
for damage and check orientation is correct as per diagram.
• Cheese-head screws should be tightened with a torque of 3 to 3.05
Nom.
• Each Nyltite should not have torque applied more than 5 times.
15748E00

Mounting and installation
12 222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
7.2.4 Electrical Connection
Key Components
Cable Connection
Interconnection of devices parallel
Up to 10 devices with common supplies may be connected as a single system loop. See
wiring diagrams for further information.
15257E00 15258E00
Key components YL60 DC Key components YL60 AC
Legend
7 = Terminal blocks
8 = Connector for sounder
9 = Tone selection switch (ton table)
10 = Link for combined function (DC-version only)
15266E00
Link connected:
• Strobe and sounder work together.
Link removed:
• Strobe and sounder independent
function.
Detail: link for combined function YL60 DC
= Strobe
= Sounder
Approximately 20 cm (8 Inch) tails are required inside the enclosure for con-
nection to the terminals on the PCB. This is especially important for
installation using solid core cable. Care is needed when re-inserting the
PCB.The terminals accept wires of 2.5 mm2 or 14 ... 18 AWG.
7
8
910
7
8
9
0V
+V
LK1
LK2

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Mounting and installation
13
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Circuit diagrams
DC voltage variants
• Links connected use only TB2.
• Diagrams show independet function with Links removed.
Line monitoring for devices with DC
• using reverse polarity
• by connecting an EOL resistor between 0 V and +V. The resistance
value is defined by the system developer.
Two signal levels for devices with DC
• using reverse polarity
• by connecting the third wire.
Two signal levels for devices with AC
• by connecting the third wire.
15263E00
16446E00
Wiring diagramm DC voltages
(second stage by third wire)
Wiring diagramm DC voltages
(second stage by reverse polarity)
15263E00
Wiring diagramm DC voltages
(telephone initiate)
0V
+V
1
+V
1
2
3
4
1
2
3
4
1
2
3
4
+V 2
1
2
TB1
TB2
TB3
0V
+V
+V
+V
0V
0V
+V
= 1
1
2
3
4
1
2
3
4
1
2
3
4
+V
=2
TB1
TB2
TB3
0V
+V
+V
0V
0V
0V
+V
0V
+V
1
2
3
4
1
2
TB1
TB2
TB3
0V
+V
0V

Mounting and installation
14 222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
AC voltage variants
7.2.5 Earth Connection
16447E00
15260E00
Wiring diagramm AC voltages Wiring diagramm AC voltages
(telephone initiate)
= Strobe
= Sounder
= Earth
= Sounder Stage 1
= Sounder Stage 2
= Sounder Tone
= Telephone initiate
15265E00
• The unit must be connected to a good quality earth.
• The internal Earth connection is the primary point. The external connection is for a
supplementary bonding connection and is used where local code or authorities
permit or require such connection.
T1B Sounder
TB2 Strobe
TB3 Neutral
TB4 Control
L L NL L
2
1
NLL
NN
TB2
TB3
TB4
N NL L
TB1
1
2

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Mounting and installation
15
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
7.2.6 Sound Tone Selection
• For signal tone selection and its switch positions refer to the table below.
• Check if the correct switch positions of the selected signal tones have been selected
for the alert phase 1 and 2.
Tone table
Tone
no.
Version Frequency
Sound
selection
switch
12345
(ON = 1)
Repetition
rate (sec) Special application
Tone 01 Alternate two-tone 800-1000 11111 0.5 Fire alarms - Level crossing
Tone 02 Alternate two-tone 2500-3100 01111 0.5 Security alarms
Tone 03 Alternate fast two-tone 800-1000 10111 0.25 Increased urgency - Level crossing
Tone 04 Alternate fast two-tone 2500-3100 00111 0.25 Security deterrent
Tone 05 Alternate two-tone 440-554 11011 0.4/0.1 AFNOR, France
Tone 06 Alternate two-tone 430-470 01011 1.0
Tone 07 Alternate very fast two-tone 800-1000 10011 0.13
Tone 08 Alternate very fast two-tone 2500-3200 00011 0.07
Tone 09 Alternate two-tone 440-554 11101 2.0 Turn out, Sweden (SS 031711)
Tone 10 Continuous tone 700 01101 All clear, Sweden (SS 031711)
Tone 11 Continuous tone 1000 10101
Tone 12 Continuous tone 1000 00101
Tone 13 Continuous tone 2300 11001
Tone 14 Continuous tone 440 01001
Tone 15 Interrupted tone 1000 10001 2.0
Tone 16 Interrupted tone 420 00001 1.25 AS2220, Australia
Tone 17 Interrupted tone 1000 11110 0.5
Tone 18 Interrupted tone 2500 01110 0.25
Tone 19 Interrupted tone 2500 10110 0.5
Tone 20 Interrupted tone 700 00110 6/12 Pre-vital message, Sweden
Tone 21 Interrupted tone 1000 11010 1.0
Tone 22 Interrupted tone 700 01010 4.0 Air-raid alarm, Sweden
Tone 23 Interrupted tone 700 10010 0.25 Local warning, Sweden
Tone 24 Interrupted tone 720 00010 0.7/0.3 Industrial alarm, Germany
Tone 25 Interrupted, fast, rising
volume
1400 11100 0.25
Tone 26 Fast siren 250-1200 01100 0.085
Tone 27 Rising constant, fall 1000 10100 10/40/10 Industrial alarm, Germany
Tone 28 ISO 8201 Evacuation 800-1000 00100 As stand-
ard
International evacuation alarm
Tone 29 Fast whoop 500-1000 11000 0.15
Tone 30 Slow whoop 500-1200 01000 4.5 Evacuation, The Netherlands
Tone 31 Reverse sweep 1200-500 10000 1.0 Fire alarm, Germany (DIN 33404)
Tone 32 Siren 500-1200 00000 3.0

Commissioning
16 222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
The PFEER sound signals recommended by UKOOA are:
Sound selection switch detail
7.3 Installation
8 Commissioning
Before commissioning, ensure that
• the device has been installed according to regulations.
• the power supply voltage and the rated operational voltage are identical.
• the required cable diameter for cable glands has been used.
General alarm Sound signal 15 Interrupted tone 1000 Hz
PAPA Sound signal 31 Reverse sweep 1200-500 Hz
Toxic gas Sound signal 11 Continuous tone 1000 Hz
15268E00 15269E00
Standard Telephone initiate
WARNING
Danger of an electric shock by energized parts!
Failure to comply can result in serious injury or death.
• All connections and wiring must be disconnected from the power supply.
• Secure the connections against unauthorized switching.
DANGER
Explosion hazard!
Risk of injuries and material damage!
• Operate the device only if it is not damaged.
• If the thread is damaged, the device must be replaced immediately.
• Handle the device and the components very carefully.
• Exposed joint surfaces must be protected from dust, dirt and damage.
• Mount the end flanges squarely and do not apply any force.
• Do not use a hammer or any other metal instruments to work on the
flange.
• Do not use the fixing screws to pull down the flange.
• Install the device only in a clean and dry operating environment.
DANGER
Explosion hazard due to incorrect installation!
Failure to comply can result in serious injury or death.
• Check the device for proper installation and function before
commissioning.
• Observe the national regulations.
SW1
ON = 1
12345
ON
1
SW2
12345
ON
2
SW1
ON = 1
12345
ON
1

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Operation
17
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
• the cable entries and stopping plugs have been securely tightened.
• the cables are correctly connected.
• the connection has been performed correctly.
• all screws and nuts are tightened according to regulations.
• the connection chamber is clean.
• the device is not damaged.
• no foreign bodies are inside the device.
• the device is sealed according to regulations.
9 Operation
The device is used to warn and alert by means
• of a sound signal.
• of a visual signal.
9.1 Troubleshooting
If an error occurs please re-visit the earlier sections of this document.
If the error cannot be eliminated using the mentioned procedures:
• Contact the local representative of R. STAHL Schaltgeräte GmbH.
For fast processing, have the following information ready:
• Type and serial number
• Purchase information
• Error description
• Intended use (in particular input / output wiring)
10 Maintenance and repair
10.1 Maintenance
• Consult the relevant national regulations to determine the type and extent of
inspections.
• Adapt inspection intervals to the operating conditions.
WARNING
Risk of electric shock or malfunctioning of the device due to unauthorized
work!
Non-compliance can result in severe injuries and material damage.
• Work performed on the device must only be carried out by appropriately
authorized and qualified electricians.
Observe the relevant national regulations in the country of use.

Cleaning
18 222936 / YL6060300020
2014-10-20·BA00·III·en·00
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
The following tests and measures must be carried out during regular maintenance.
10.2 Repair
10.3 Returning the device
Use the "Service form" to return the device when repair/service is required. On the
internet site "www.stahl-ex.com" under "Downloads > Customer service":
• Download the service form and fill it out.
• Send the device along with the service form in the original packaging to
R. STAHL Schaltgeräte GmbH.
11 Cleaning
• Clean the device only with a cloth, brush, vacuum cleaner or similar items.
• When cleaning with a damp cloth, use water or mild, non-abrasive, non-scratching
cleaning agents.
• Do not use aggressive detergents or solvents.
12 Disposal
• Observe national and local regulations and statutory regulation regarding disposal.
• Separate materials when sending it for recycling.
• Ensure environmentally friendly disposal of all components according to the statutory
regulations.
Check Measures
the permissible ambient temperature If exceeding the permissible ambient
temperature or falling below the device
must be taken out of operation.
the enclosure components for formation of
cracks and damage.
Replace the exchangeable enclosure
components. If the enclosure components
are non-exchangeable, the device must be
taken out of operation.
its intended use If the device is not used according to its
intended use, it must be taken out of
operation.
if the conductors are clamped properly clamp loose conductors tightly.
the cables for ageing and damage replace damaged or aged cables.
the seals for ageing and damage replace damaged, aged and porous seals
and completely change enclosure
components with foamed seal.
DANGER
Explosion hazard due to improper repair!
Non-compliance results in severe or fatal injuries.
• Repair work on the devices must be performed only by
R.STAHL Schaltgeräte GmbH.

222936 / YL6060300020
2014-10-20·BA00·III·en·00
Accessories and Spare parts
19
Explosion Proof Combination Signal
– 110 dB (A) / 5 Joule
Series YL60
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
13 Accessories and Spare parts
NOTICE
Use only original accessories and spare parts by R. STAHL Schaltgeräte GmbH.
For accessories and spare parts, see data sheet on our homepage
www.stahl-ex.com.

EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
EN
Table of contents
Other Stahl Security System manuals

Stahl
Stahl YL6S Series User manual

Stahl
Stahl Clifford & Snell YL50 User manual

Stahl
Stahl 8491/2 Series User manual

Stahl
Stahl YL6S Series User manual

Stahl
Stahl FX15 Series User manual

Stahl
Stahl YA60 Series User manual

Stahl
Stahl YA11 User manual

Stahl
Stahl YA60 Series User manual

Stahl
Stahl Clifford & Snell Y05 User manual

Stahl
Stahl YA50 Series User manual