– 18 – – 19 –
GB
8. Accessories
Floating module MPF 1: EAN 4007841609115
Smart Remote: EAN 4007841009151
9. Operation / maintenance
The infrared sensor can be used for switching light
ON and OFF automatically. The unit is not suitable
for burglar alarm systems as it is not tamperproof in
the manner prescribed for such systems. Weather
conditions may aect the way the motion detector
works. Strong gusts of wind, snow, rain or hail may
cause the light to come ON when it is not wanted
because the sensor is unable to distinguish between
sudden changes of temperature and sources of
heat. The detector lens may be cleaned with a damp
cloth if it gets dirty (do not use cleaning agents).
10. EC Declaration of Conformity
Hereby, STEINEL Vertrieb GmbH declares that the
radio equipment type SensIQ eNet is in compliance
with Directive 2014/53/EU. The full text of the
EU declaration of conformity is available at the
following internet address: www.steinel.de
11. Disposal
Electrical and electronic equipment, accessories
and packaging must be recycled in an environmen-
tally compatible manner.
Do not dispose of electrical and electronic
equipment as domestic waste.
EU countries only:
Under the current European Directive on Waste
Electrical and Electronic Equipment and its imple-
mentation in national law, electrical and electronic
equipment no longer suitable for use must be
collected separately and recycled in an environ-
mentally compatible manner.
12. Manufacturer’s Warranty
As purchaser, you are entitled to your statutory
rights against the vendor. If these rights exist in
your country, they are neither curtailed nor restrict-
ed by our Warranty Declaration. We guarantee
that your STEINEL Professional sensor product
will remain in perfect condition and proper working
7Pressing this button in sensor mode
switches the light ON for 4 hours (the status
LED lights up permanently). Pressing this
button in 4h ON mode switches the light
OFF for 4 hours (the status LED lights up
permanently). The 4h mode is terminated
after the time elapses, by pressing the reset
button or by pressing the 4h button in the
4h OFF mode.
8Install mode (test mode)
Install mode has the purpose of checking
for proper working order as well for testing
the detection zone. Irrespective of light
level, the light switches ON for 5s in
response to movement. Movement is
signalised by the status LED.
Install mode has priority over all other
settings. Install mode ends automatically
after 10minutes.
Install mode ends immediately after press-
ing reset.
Note: Teach mode and Install mode
cannot be used at the same time.
9Reset
Resets all settings to the values selected on
the light manually or to the factory settings.
10 Sensor
Sensor channel programming mode
(eNet products only)
Press the button for approx. 5s until the
eNet sensor LED flashes. If the actuator
channel of the other device is also in
programming mode, briefly press the
button once again.
Deleting sensor channel connection
Press the button for approx. 20s until
the eNet sensor LED flashes rapidly,
then briefly press the button once again.
Programming mode / connecting to
eNet server
Press the button for approx. 5s until
the eNet sensor LED flashes.
11 Actuator
Actuator channel programming mode
(eNet products only)
Press the button for approx. 5s until the
eNet actuator channel LED flashes.
Deleting actuator channel connection
Press the button for approx. 20s until the
eNet actuator channel LED flashes rapidly,
then briefly press the button once again.
order for a period of 5years. We guarantee that
this product is free from material-, manufacturing-
and design flaws. In addition, we guarantee that all
electronic components and cables function in the
proper manner and that all materials used and their
surfaces are without defects.
Making Claims
If you wish to make a claim, please send your prod-
uct complete and carriage paid with the original
receipt of purchase, which must show the date of
purchase and product designation, either to your
retailer or contact us at STEINEL (UK) Limited,
25Manasty Road, Axis Park, Orton Southgate,
Peterborough, PE2 6UP, for a returns number.
For this reason, we recommend that you keep
your receipt of purchase in a safe place until the
warranty period expires. STEINEL shall assume no
liability for the costs or risks involved in returning a
product.
For information on making claims under
the terms of the warranty, please go to
www.steinel-professional.de/garantie
If you have a warranty claim or would like to ask
any question regarding your product, you are wel-
come to call us at any time on our Service Hotline
01733 366700.
MANUFACTURER'S
YEAR
WARRANTY
13. Technical specifications
Dimensions (H × W × D) 144 × 113 × 172 mm
Additional switching capacities Incandescent / halogen lamp load
Fluorescent lamps, electronic ballast
Fluorescent lamps, uncorrected
Fluorescent lamps, series-corrected
Fluorescent lamps, parallel-corrected
Low-voltage halogen lamps
LED < 2 W
2 W < LED < 8 W
LED > 8 W
Capacitive load
2500 W
1500 W
1000 VA
1800 VA
500 VA
2300 VA
16 W
64 W
64 W
176 μF
Starting current C < 176 µF, max. 8 LED/fluorescent lamps
Voltage supply 220-240V AC, 50/ 60Hz
Angle of coverage 300° with 180° angle of aperture as well as sneak-by guard and
coverage directly below the sensor. Capability of masking out
detection zone in segments
Reach Adjustable in 3 directions via control dial independently of each other,
(2-20m, temperature-stabilised)
Sensor system 4 sensors, 6 detection levels for long-distance detection
and 5 for sneak-by guard, 1360switching zones
Time setting 5s - 15min, pulse mode (approx. 2s)
Twilight setting 2-2000lux
Manual override (permanent light) selectable (4h)
Permanently OFF selectable (4h) / (via remote control only)
IP rating IP54 through 2K technology
Temperature range -20°C to +50°C
For eNet version only
Radio frequency 868.3 MHz
Transmitter power max. 20mW
Reach in the open max. 100m