- 12 - - 13 -
Technical Specifications
Dimensions: (H x W x D): 115 x 115 x 50.5 mm
Output:
incandescent lamps, 2000 W max. at 230 V AC
fluorescent lamp, 500 VA max., at cos ϕ= 0.5,
inductive load at 230 V AC
6 x 58 W, C ≤ 132 μF,
at 230 V AC *1)
Power supply: 220-240 V, 50/60 Hz
Angle of coverage 360° with 180° angle of aperture
Reach: 3.5 m max. tangentially
2 m max. radially
Time setting: 8 sec. - 35 min.
Light-level setting: 2-2000 lux
IP rating: IP 54
Temperature range: -20 °C to +50 °C
*1) Fluorescent lamps, low-energy lamps, LED lights with electronic ballast
(total capacity of all ballasts connected below the level stated).
Declaration of Guarantee
All rights are based on our
guarantee period. We guaran-
tee that your STEINEL Profes-
sional sensor product will
remain in perfect condition
and proper working order for
a period of 5 years. We guar-
antee that this product is free
from material, manufacturing
and design flaws. In addition,
we guarantee that all electronic
components and cables func-
tion in the proper manner and
that all materials used and
their surfaces are without
defects.
Making Claims
If you wish to make a claim,
please send your product
complete and carriage paid
with the original receipt of pur-
chase, which must show the
date of purchase and product
designation, either to your
retailer or directly to us at
STEINEL (UK) Limited,
25 Manasty Road, Axis Park,
Orton Southgate, Peterbor-
ough, PE2 6UP. For this rea-
son, we recommend that you
keep your receipt of purchase
in a safe place until the guar-
antee period expires. STEINEL
shall assume no liability for
the costs or risks involved in
returning a product.
For information on making
claims under the terms of
the guarantee, please go to
www.steinel-professional.
de/garantie
If you have a guarantee claim
or would like to ask any ques-
tion regarding your product,
you are wel-come to call us
at any time on our service
hotline 01733 366700.
Troubleshooting
Malfunction Cause Remedy
Without power Fuse faulty,
not switched ON
Short-circuit
Replace fuse, turn ON
mains switch, check lead
with voltage tester
Check connections
Does not switch ON Twilight setting in
night-time mode during
daytime operation
Bulb faulty
Mains switch OFF
Fuse faulty
Readjust
Replace light bulbs
Switch ON
Fit new fuse, check
connection if necessary
Does not switch OFF Continuous movement in
the detection zone
Light being operated is
located in detection zone
and keeps switching ON
as a result of temperature
change
Set to continuous opera-
tion by indoor two-circuit
single interruption switch
Check zone
Check zone
Set two-circuit single inter-
ruption switch to automatic
operation
Keeps switching ON/OFF Light being operated is
located in detection zone
Animals moving in the
detection zone
Check zone
Check zone
Switches ON when it
should not
Wind is moving trees and
bushes in the detection
zone
Cars in the street are being
detected
Sudden temperature
changes due to weather
(wind, rain, snow) or air
expelled from fans,
open windows
Check zone
Check zone
Change detection zone,
change site of installation
GB