STI STI-7534 User manual

- 1 -
Protective Cabinet
STI-7534, STI-7535 and STI-7535MED
We protect the things that protect you.®
Features
· Clear, protective polycarbonate cover with siren/strobe alarm.
· Design allows visibility at any angle.
· Complete with mounting hardware and gasket.
· Includes wire shelf, backing plate and siren/strobe alarm — MED models
· External mounting tabs or internal drill dimples.
· Cover includes a coated steel internal mounting plate with a baked on white
enamel finish.
· Siren/strobe alarm lens is red. Also available with amber, green, blue or white lens.
· Siren offers 32 user selectable tones.
· Alarm can be set for a piercing 100 dB or 85 dB.
· Independent strobe and siren timing of 15 seconds, 30 seconds, 60 seconds or
continuous.
· Powered by a 9 VDC battery or external 12-30 volts.
· Low battery indicator.

- 2 -
Table of Contents
Warnings .................................................................................................................... page 2
Cleaning Instructions ................................................................................................. page 2
Dimensions................................................................................................................. page 3
Specifications ............................................................................................................ page 3
Installation of Cabinet ................................................................................................ page 4
Installation of Alarm .................................................................................................... page 4
Alarm Electronic Setup ............................................................................................... page 5
Alarm Tones .............................................................................................................. page 5
Alarm Timing and Volume ........................................................................................... page 5
Alarm Electronics Assembly........................................................................................ page 6
Alarm Terminal Strip Connections ............................................................................... page 6
Assembly Parts List ................................................................................................... page 7
Operation .................................................................................................................. page 7
Warranty..................................................................................................................... page 7
Accessories & Replacement Parts .............................................................................. page 8
Warnings
All units are recommended for indoor use. Unit must be tested periodically to verify the life
of battery. STI recommends you change the 9 Volt battery twice a year. When purchasing
a siren/strobe alarm, you will need to periodically test the connections to make sure audibles
function at a sound level to alert staff. Installer may need to purchase a simple audio-meter,
typically available at your local electronics store, to measure the sound in areas where the
alarm is expected to be heard during normal noise environment. Results from this test may
prove it beneficial to purchase additional siren/strobe alarm units.
All specifications and information shown are current as of publication and subject to change
without notice.
Cleaning
1. Rinse cover with water to remove abrasive dust and dirt.
2. Wash with soap or mild detergent using a soft cloth. (DO NOT SCRUB.)
3. Rinse once more, then dry with a soft cloth or chamois.
4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly with naphtha, then
wash and rinse. (DO NOT USE RAZOR BLADES.)

- 3 -
Specifications
Operating Voltage Internal power 9 VDC battery (not included)
Remote power 12-30 VDC
Operating Temperature 32°F -120°
Power Consumption Stand by: 50µA
Siren low volume: 85mA
Siren high volume: 90mA
Strobe: 25mA
Siren Volume Low: 85 dB
High: 100 dB
Alarm Timing Independent control for siren and strobe:
15s, 30s, 60s, continuous
Low Battery Warning LED flash once every 30 seconds
Form C Dry Contacts 0-30VAC/DC, 1 Amp
rated for Contacts reset after longest alarm setting
Key Switch Alarm on: normally closed
Alarm Switch Stand by: normally open contact required
Polycarbonate UL94V-2
Dimensions
12 in.
(305mm)
14 in.
(356mm)
INTERNAL PRODUCT DIMENSIONS
STI-7530
04875 ALUMINUM PLATE
19001 SCREW
#8 32 X 3/8 in.
(4) PROVIDED
7530 COVER
14.2 in.
(361mm)
12.2 in.
(310mm)
6.44 in.
(164mm)
TOP VIEW
FRONT VIEW
14.2 in.
(361mm)
12.2 in.
(310mm)
PRODUCT DIMENSIONS
STI-7531AED
STI-7533AED
BOTTOM VIEW
FRONT VIEW
TOP VIEW
FRONT VIEW
6.44 in.
(164mm)
07530WR
WIRE SHELF ON AED
MODELS (ADJUSTABLE)
STI-7531AED models only
COATED STEEL
BACKPLATE PROVIDED
STOP
EMERGENCY USE ONLY
6.44 in.
(164mm)
23 in.
(584mm)
B
A
PRODUCT DIMENSIONS
STI-7531AED
STI-7533AED
END VIEW
FRONT VIEW
STOP
EMERGENCY USE ONLY
C
E
D
14.2 in.
(361mm)
12.2 in.
(310mm)
6.44 in.
(164mm)
14.2 in.
(361mm)
12.2 in.
(310mm)
6.44 in.
(164mm)
TOP VIEW
FRONT VIEW
SAMPLE OF
SIREN
ALARM
14.2 in.
(360mm)
12.2 in.
(310mm)
BOTTOM VIEW
FRONT VIEW
6.44 in.
(164mm)
23.5 in.
(597mm)
16.5 in.
(419mm)
1/4” DIA.
1/4” DIA.
1/4”
DIAMETER
Flammability Rating

- 4 -
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
Installation of Shelf (included with STI-7535AED)
Note: Installation of cabinet
should be before
installation of alarm
because the mounting
bracket butts up to
cabinet.
Installation of Alarm
STEP 1 - Mounting Options
To key mount plate or into wall without electrical box
1. Insert the (4) M06298
mounting tabs fully into
backbox mounting tab
slots. Use rubber mallet if
necessary.
2. After selecting a suitable
location, place cabinet in
closed position, against the
wall. Mark and drill (4) 1/4
in. diameter holes. Insert the
(4) 19033 anchors. Mount
cabinet by driving in the four
#10 x 1 1/2 in. screws.
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
NO
COM
NC
ALARM SWITCH
KEY SWITCH
DC IN -
DC IN +
Install 4/05
FRONT SIDE
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
S1
ALARM TONES
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
REMOTE POWER IN
12-24 VDC, 125mA
+
-
OFF ON
**MAIN POWER
CONTROL
ACTIVE STAND BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY
OPEN
NORMALLY
CLOSED
COM
DRILL
3/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
TO KEY MOUNT PLATE OR INTO WALL
BASE PLATE
H18074 SWITCH LOCK
KIT-SA505 KEY SWITCH
MOUNTING BRACKET
SINGLE GANG
ELECTRICAL BOX
#6-32 x 1 1/2 in. SCREW
(2) PROVIDED
TO SINGLE GANG ELECTRICAL BOX
BASE PLATE
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
#8-32 x 3/8 in. SCREW
(4) PROVIDED
05000 ELECTRONICS
ELECTRONICS ASSEMBLY FINAL
INSTALLED
BASE PLATE
2 13/32 in.
19018 ANCHOR
#8-10
(4) PROVIDED
DRILL (4)
3/16 in. DIA HOLES
KIT-SA504 BACKBOX
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19068 SCREW
#6 x 5/8 in.
(4) PROVIDED
BASE PLATE
TO STI BACKBOX 71100A
71100B-W
BRIDGE INSERT
1 31/32 in.
3 9/32 in.
WIRE ACCESS HOLE
TAMPER-PROOF
TOOL (1) PROVIDED
TAMPER-PROOF SCREW
2 13/32 in.
19018 ANCHOR
#8-10
(4) PROVIDED
DRILL (4)
3/16 in. DIA HOLES
KIT-71100A-W BACKBOX
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19068 SCREW
#6 x 5/8 in.
(4) PROVIDED
BASE PLATE
71100B-W
BRIDGE INSERT
1 31/32 in.
DRILL
3/16 DIA HOLES
ANCHOR
#8-10
(2) PROVIDED
#6 x 1 1/4 in. SCREW
(2) PROVIDED
BASE PLATE
H18074 SWITCH LOCK
KIT-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
REMOTE POWER IN
12-24 VDC, 125mA
+-OFF ON
**MAIN POWER
CONTROL
STAND
BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
1.58 in.
2.725 in.
4.75 in.
4.83 in.
3.05 in.
3.22 in.
3.25 in.
4.83 in.
1.58 in.
2.725 in.
4.75 in.
4.83 in.
3.05 in.
3.22 in.
3.25 in.
4.83 in.
3.25 in.
(83mm)
4.83 in.
(123mm)
FRONT SIDE
3.25 in.
(83mm)
4.83 in.
(123mm)
1.58 in.
(40mm)
2.73 in.
(69mm)
2.73 in.
(69mm)
LENS COVER
BACKPLATE
MOUNTING PLATE
ELECTRONICS
19011 TAMPERPROOF SCREW
KEY SWITCH
LENS COVER
BACKPLATE
KEY SWITCH
MOUNTING PLATE
19011 TAMPERPROOF SCREW
ELECTRONICS
#801 KEY
#801 KEY
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+-OFF ON
**MAIN POWER
CONTROL TO
KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
DRILL (4) 3/16 in. DIA. HOLES IF USING #8-10 ANCHORS.
DRILL (4) 3/32 in. DIA. HOLES WHEN USING #6 SCREWS ONLY.
19018 ANCHOR
#8-10
(4) PROVIDED
SUB-71100A-W
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19060 SCREW
#6-32 x 1 in.
(2) PROVIDED
BASE PLATE
1-24-11
NOTE TO BECK:
This sketch replaces
(Step 5 - Mounting Options VIEW A)
in STI-SA5000 install sheet.
1. Using 5/32 Drill, Drill through the (4) exsisting holes in backbox (one in each corner).
2. Place backbox on wall and mark the mounting hole positions.
3. If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole.
If using #6 screws only, drill 3/32 dia. holes 1-1/4 in. deep.
4. Mount backbox to wall using #6 x 1 1/4 screws.
5. Mount base plate as shown using (2) #6-32 x 1 in. screws.
NOTE: If not using STI backbox, make sure surface will depress tamper switch.
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
CABINET
#10 x 1 1/2 in. SCREW
(4) PROVIDED
MOUNTING TAB
(4) PROVIDED
#10-12 WALL ANCHOR
(4) PROVIDED
MOUNTING POSTS
WIRE SHELF
#8 WASHER
(2) PROVIDED
#8-32 x 1/2 in. MACHINE SCREW
(2) PROVIDED
PERPROOF SCREW
MPER SCREW TOOL
#8 x 1 in. SCREW (4) PROVIDED
ALARM COVER
SIREN MOUNTING
PLATE ALARM MOUNTING PLATE
MAGNETIC SWITCH WITH WIRES
9 VOLT BATTERY
#8-10 WALL ANCHOR
(4) PROVIDED
CABINET
MOUNTING TAB SLOTS
#10-12 WALL ANCHOR
(4) PROVIDED
MOUNTING TAB
(4) PROVIDED
#10 x 1 1/2 in. MOUNTING SCREW
(4) PROVIDED
MOUNTING
POSTS
WIRE SHELF
#8 WASHER
(2) PROVIDED
#8-32 x 1/2 in. MACHINE SCREW
(2) PROVIDED
TAMPER SCREW TOOL
TAMPER SCREW TOOL
TAMPERPROOF SCREW
CABINET#10 x 1 1/2 in. SCREW
(4) PROVIDED
MOUNTING TAB
(4) PROVIDED
#10-12 WALL
ANCHOR
(4) PROVIDED
MOUNTING
POSTS
WIRE SHELF
#8 WASHER
(2) PROVIDED
#8-32 x 1/2 in. MACHINE SCREW
(2) PROVIDED
Installation of Cabinet
1. Align wire shelf to bottom mounting posts inside the cabinet.
2. Insert (2) #8-32 x ½ in. machine screw, through #8 washer, into mounting post and tighten.

- 5 -
Step 3 - Alarm Tones - S1
1 00000 BUZZ
2 10000 SLOW ON/OFF
3 01000 SLOW SIREN
4 11000 3 BEEP/PAUSE/REPEAT
5 00100 UFO FAST
6 10100 FAST SIREN
7 01100 #5 FAST
8 11100 #2 MEDIUM
9 00010 #5 MEDIUM
10 10010 SWOOP MEDIUM
11 01010 #3 MEDIUM
12 11010 BUZZ TONE
13 00110 STEADY FAST
14 10110 SWOOP SLOW
15 01110 CONTINUOUS
16 11110 FAST REPEAT
17 00001 STANDARD ALARM
18 10001 #3 FAST
19 01001 #5 SLOW
20 11001 FAST BEEP
21 00101 SOUND A
22 10101 SOUND B
23 01101 SOUND C
24 11101 SOUND D
25 00011 SOUND D LOUD
26 10011 SOUND E
27 01011 SOUND F
28 11011 SOUND G
29 00111 SOUND H
30 10111 #4 LOW
31 01111 SOUND K
32 11111 CONTINUOUS FAST
12345 12345
*
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
NO
COM
NC
ALARM SWITCH
KEY SWITCH
DC IN -
DC IN +
Install 4/05
FRONT SIDE
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
S1
ALARM TONES
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
REMOTE POWER IN
12-24 VDC, 125mA
+
-
OFF ON
**MAIN POWER
CONTROL
ACTIVE STAND BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY
OPEN
NORMALLY
CLOSED
COM
DRILL
3/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
TO KEY MOUNT PLATE OR INTO WALL
BASE PLATE
H18074 SWITCH LOCK
KIT-SA505 KEY SWITCH
MOUNTING BRACKET
SINGLE GANG
ELECTRICAL BOX
#6-32 x 1 1/2 in. SCREW
(2) PROVIDED
TO SINGLE GANG ELECTRICAL BOX
BASE PLATE
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
#8-32 x 3/8 in. SCREW
(4) PROVIDED
05000 ELECTRONICS
ELECTRONICS ASSEMBLY FINAL
INSTALLED
BASE PLATE
2 13/32 in.
19018 ANCHOR
#8-10
(4) PROVIDED
DRILL (4)
3/16 in. DIA HOLES
KIT-SA504 BACKBOX
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19068 SCREW
#6 x 5/8 in.
(4) PROVIDED
BASE PLATE
TO STI BACKBOX 71100A
71100B-W
BRIDGE INSERT
1 31/32 in.
3 9/32 in.
WIRE ACCESS HOLE
TAMPER-PROOF
TOOL (1) PROVIDED
TAMPER-PROOF SCREW
2 13/32 in.
19018 ANCHOR
#8-10
(4) PROVIDED
DRILL (4)
3/16 in. DIA HOLES
KIT-71100A-W BACKBOX
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19068 SCREW
#6 x 5/8 in.
(4) PROVIDED
BASE PLATE
71100B-W
BRIDGE INSERT
1 31/32 in.
DRILL
3/16 DIA HOLES
ANCHOR
#8-10
(2) PROVIDED
#6 x 1 1/4 in. SCREW
(2) PROVIDED
BASE PLATE
H18074 SWITCH LOCK
KIT-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
REMOTE POWER IN
12-24 VDC, 125mA
+-OFF ON
**MAIN POWER
CONTROL
STAND
BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
1.58 in.
2.725 in.
4.75 in.
4.83 in.
3.05 in.
3.22 in.
3.25 in.
4.83 in.
1.58 in.
2.725 in.
4.75 in.
4.83 in.
3.05 in.
3.22 in.
3.25 in.
4.83 in.
3.25 in.
(83mm)
4.83 in.
(123mm)
FRONT SIDE
3.25 in.
(83mm)
4.83 in.
(123mm)
1.58 in.
(40mm)
2.73 in.
(69mm)
2.73 in.
(69mm)
LENS COVER
BACKPLATE
MOUNTING PLATE
ELECTRONICS
19011 TAMPERPROOF SCREW
KEY SWITCH
LENS COVER
BACKPLATE
KEY SWITCH
MOUNTING PLATE
19011 TAMPERPROOF SCREW
ELECTRONICS
#801 KEY
#801 KEY
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+-OFF ON
**MAIN POWER
CONTROL TO
KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
DRILL (4) 3/16 in. DIA. HOLES IF USING #8-10 ANCHORS.
DRILL (4) 3/32 in. DIA. HOLES WHEN USING #6 SCREWS ONLY.
19018 ANCHOR
#8-10
(4) PROVIDED
SUB-71100A-W
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19060 SCREW
#6-32 x 1 in.
(2) PROVIDED
BASE PLATE
1-24-11
NOTE TO BECK:
This sketch replaces
(Step 5 - Mounting Options VIEW A)
in STI-SA5000 install sheet.
1. Using 5/32 Drill, Drill through the (4) exsisting holes in backbox (one in each corner).
2. Place backbox on wall and mark the mounting hole positions.
3. If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole.
If using #6 screws only, drill 3/32 dia. holes 1-1/4 in. deep.
4. Mount backbox to wall using #6 x 1 1/4 screws.
5. Mount base plate as shown using (2) #6-32 x 1 in. screws.
NOTE: If not using STI backbox, make sure surface will depress tamper switch.
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
Note: Sound may be disabled by clipping wires to
the siren. THIS WILL VOID ALL WARRANTIES.
Remove two screws on circuit board; leave
enough length of wire to possibly reattach
in the future. Then insulate wires to prevent
shorting to electronic components.
WIRES TO
SIREN
Step 4 - Alarm Timing
and Volume - S2
1
ALARM TIMING VOLUME
STROBE TIMING
ON
OFF
1
2345
0
15 seconds 1 1 1 1
30 seconds 1 0 1 0
60 seconds 0 1 0 1
Continuous 0 0 0 0
ALARM
TIMING
SIREN STROBE VOLUME
1234 5
High
1
Low
2
1 = ON 0 = OFF
*Factory default settings
*
STEP 2 - Electronic Setup
Select alarm tone and timing sequence
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
NO
COM
NC
ALARM SWITCH
KEY SWITCH
DC IN -
DC IN +
Install 4/05
FRONT SIDE
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
S1
ALARM TONES
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
REMOTE POWER IN
12-24 VDC, 125mA
+
-
OFF ON
**MAIN POWER
CONTROL
ACTIVE STAND BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY
OPEN
NORMALLY
CLOSED
COM
DRILL
3/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
TO KEY MOUNT PLATE OR INTO WALL
BASE PLATE
H18074 SWITCH LOCK
KIT-SA505 KEY SWITCH
MOUNTING BRACKET
SINGLE GANG
ELECTRICAL BOX
#6-32 x 1 1/2 in. SCREW
(2) PROVIDED
TO SINGLE GANG ELECTRICAL BOX
BASE PLATE
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
#8-32 x 3/8 in. SCREW
(4) PROVIDED
05000 ELECTRONICS
ELECTRONICS ASSEMBLY FINAL
INSTALLED
BASE PLATE
2 13/32 in.
19018 ANCHOR
#8-10
(4) PROVIDED
DRILL (4)
3/16 in. DIA HOLES
KIT-SA504 BACKBOX
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19068 SCREW
#6 x 5/8 in.
(4) PROVIDED
BASE PLATE
TO STI BACKBOX 71100A
71100B-W
BRIDGE INSERT
1 31/32 in.
3 9/32 in.
WIRE ACCESS HOLE
TAMPER-PROOF
TOOL (1) PROVIDED
TAMPER-PROOF SCREW
2 13/32 in.
19018 ANCHOR
#8-10
(4) PROVIDED
DRILL (4)
3/16 in. DIA HOLES
KIT-71100A-W BACKBOX
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19068 SCREW
#6 x 5/8 in.
(4) PROVIDED
BASE PLATE
71100B-W
BRIDGE INSERT
1 31/32 in.
DRILL
3/16 DIA HOLES
ANCHOR
#8-10
(2) PROVIDED
#6 x 1 1/4 in. SCREW
(2) PROVIDED
BASE PLATE
H18074 SWITCH LOCK
KIT-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
REMOTE POWER IN
12-24 VDC, 125mA
+-OFF ON
**MAIN POWER
CONTROL
STAND
BY
ALARM
SWITCH
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
1.58 in.
2.725 in.
4.75 in.
4.83 in.
3.05 in.
3.22 in.
3.25 in.
4.83 in.
1.58 in.
2.725 in.
4.75 in.
4.83 in.
3.05 in.
3.22 in.
3.25 in.
4.83 in.
3.25 in.
(83mm)
4.83 in.
(123mm)
FRONT SIDE
3.25 in.
(83mm)
4.83 in.
(123mm)
1.58 in.
(40mm)
2.73 in.
(69mm)
2.73 in.
(69mm)
LENS COVER
BACKPLATE
MOUNTING PLATE
ELECTRONICS
19011 TAMPERPROOF SCREW
KEY SWITCH
LENS COVER
BACKPLATE
KEY SWITCH
MOUNTING PLATE
19011 TAMPERPROOF SCREW
ELECTRONICS
#801 KEY
#801 KEY
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+-OFF ON
**MAIN POWER
CONTROL TO
KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
DRILL (4) 3/16 in. DIA. HOLES IF USING #8-10 ANCHORS.
DRILL (4) 3/32 in. DIA. HOLES WHEN USING #6 SCREWS ONLY.
19018 ANCHOR
#8-10
(4) PROVIDED
SUB-71100A-W
19039 SCREW
#6 x 1 1/4 in.
(4) PROVIDED
19060 SCREW
#6-32 x 1 in.
(2) PROVIDED
BASE PLATE
1-24-11
NOTE TO BECK:
This sketch replaces
(Step 5 - Mounting Options VIEW A)
in STI-SA5000 install sheet.
1. Using 5/32 Drill, Drill through the (4) exsisting holes in backbox (one in each corner).
2. Place backbox on wall and mark the mounting hole positions.
3. If using #8-10 anchors, drill 3/16 dia. holes 1 in. deep into wall and press anchor into hole.
If using #6 screws only, drill 3/32 dia. holes 1-1/4 in. deep.
4. Mount backbox to wall using #6 x 1 1/4 screws.
5. Mount base plate as shown using (2) #6-32 x 1 in. screws.
NOTE: If not using STI backbox, make sure surface will depress tamper switch.
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
Note: Select-Alert must be on a
flat surface and lens must
be installed or the tamper
switch will trigger the alarm.

- 6 -
Step 5 - Electronics Assembly
Step 6 - Terminal Strip Connections
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6).
Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure
with tamperproof screw and special. Unit will not operate properly if lens cover is not installed.
M05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
#8-32 x 3/8 in. SCREW
(4) PROVIDED
ELECTRONICS
INSTALLED
BASE PLATE
WIRE ACCESS HOLE
TAMPER-PROOF
TOOL (1) PROVIDED
TAMPER-PROOF
SCREW
ROUTE WIRES
THRU HOLE
Note “DC IN” are the only
polarity sensitive terminals.
When external power is
used, battery will act as
a backup. “Dry Contacts:
NC, COM, NO” are used for
remote alarm monitoring.
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+-OFF ON
MAIN POWER
CONTROL TO
KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+ -
DC IN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE

- 7 -
Assembly Parts List
QTY. PART # DESCRIPTION
1 E05000 Electronics assembly (includes base plate & electronics assembly)
1 M05050-R Red lens (unless otherwise specified)
1 M09723 Key switch mounting bracket
2 KIT-H18075 #801 key
1 H18074 Switch lock
1 KIT-E18151 N.C. reed switch and magnet (installed in cabinet)
4 Screw #8-32 x 3/8 in.
2 Screw #6 x 1 1/4 in.
2 Anchor #8-10
1 #8-32 x 1/2 in. tamper screw
1 Tamper wrench
1 BAT-9VDC 9 volt battery
CABINET
1 Hinged polycarbonate enclosure
4 M06298 Mounting tabs
4 #10 x 1 1/2 in. screw
4 Plastic anchor
1 W07532 Wire shelf (included with MED models only)
4 19002 #8-32 x 3/8 in. screw
1 H07503 Thumb lock - STI-7535 models
1 H18050 Key lock
2 KIT-H18054 CH751
SIREN/STROBE ALARM
}STI-7534 models
Step 7 - Operation
· Turn key switch onto arm.
· Cycle key switch to reset alarm
· Alarm will sound when cabinet is opened (alarm switch is electronically closed), alarm
cover is removed or unit is removed from the wall.
· To service, turn key switch off.
Warranty
Three year guarantee against breakage of polycarbonate in normal use (one year on electro
mechanical and electronic components).
Electronic warranty form at www.sti-usa.com/wc14.
WARNING: This product can expose you to chemicals including Dichloromethane, which
is known to the State of California to cause cancer, and Bisphenol A (BPA), which is
known to the State of California to cause birth defects or other reproductive harm. For
more information go to www.P65Warnings.ca.gov.

- 8 -
Inst. 7535MED 2018_12
Printed in USA Subject to change without notice.
Accessories and Replacement Parts
STI-SA5000-R Replacement Siren/Strobe Alarm - Red
KIT-H18054 Replacement key for cabinet lock on STI-7534
KIT-H18075 Replacement key for Siren/Strobe Alarm
2306 Airport Rd • Waterford, MI 48327, USA
Phone: 248-673-9898 • Fax: 248-673-1246
[email protected] • www.sti-usa.com
Taylor House • 34 Sherwood Road • Bromsgrove
Worcestershire • B60 3DR • England • Tel: +44 (0)1527 520 999
Fax: +44 (0)1527 501 999 • [email protected] • www.sti-emea.com
This manual suits for next models
3
Table of contents
Other STI Enclosure manuals