STI STI-7534 User manual

Protective Cabinet
STI-7534, STI-7535 and STI-7535AED
Features
•Clear, protective polycarbonate cover with siren/strobe alarm.
•Design allows visibility at any angle.
•Complete with mounting hardware and gas et.
•Includes wire shelf, bac ing plate and siren/strobe alarm — AED models
•External mounting tabs or internal drill dimples.
•Cover includes a coated steel internal mounting plate with a ba ed on white
enamel finish.
•Siren/strobe alarm lens is red. Also available with amber, green, blue or white lens.
•Siren offers 32 user selectable tones.
•Alarm can be set for a piercing 100 dB or 85 dB.
•Independent strobe and siren timing of 15 seconds, 30 seconds, 60 seconds or
continuous.
•Powered by a 9 VDC battery or external 12-30 volts.
•Low battery indicator.
We protect the things that protect you.

2
Warnings ..................................................................................................page 2
Cleaning Instructions ..............................................................................page 2
Dimensions ..............................................................................................page 3
Specifications ..........................................................................................page 3
Installation of Cabinet ............................................................................page 4
Installation of Alarm ................................................................................page 4
Alarm Electronic Setup ............................................................................page 5
Alarm Tones ............................................................................................page 5
Alarm Timing and Volume ......................................................................page 5
Alarm Terminal Strip Connections ..........................................................page 6
Alarm Electronics Assembly ....................................................................page 6
Assembly Parts List ................................................................................page 7
Operation ................................................................................................page 7
Warranty ..................................................................................................page 7
Accessories & Replacement Parts............................................................page 8
CONTENTS
WA NINGS
CLEANING
All units are recommended for indoor use. Unit must be tested periodically to
verify the life of battery. STI recommends you change the 9 Volt battery twice
a year. When purchasing a siren/strobe alarm, you will need to periodically
test the connections to make sure audibles function at a sound level to alert
staff. Installer may need to purchase a simple audio-meter, typically available
at your local electronics store, to measure the sound in areas where the alarm
is expected to be heard during normal noise environment. Results from this
test may prove it beneficial to purchase additional siren/strobe alarm units.
All specifications and information shown are current as of publication and
subject to change without notice.
1. Rinse cover with water to remove abrasive dust and dirt.
2. Wash with soap or mild detergent using a soft cloth. (DO NOT SCRUB.)
3. Rinse once more, then dry with a soft cloth or chamois.
4. To remove grease or wet paint, rub gently with a cloth wetted thoroughly
with naphtha, then wash and rinse. (DO NOT USE RAZOR BLADES.)

DIMENSIONS
3
SPECIFICATIONS
OPE ATING VOLTAGE Internal power 9 VDC battery (not included)
Remote power 12-30 VDC
OPE ATING TEMPE ATU E 32°F -120°
POWE CONSUMPTION Stand by: 50µA
Siren low volume: 85mA
Siren high volume: 90mA
Strobe: 25mA
SI EN VOLUME Low: 85 dB
High: 100 dB
ALA M TIMING Independent control for siren and strobe:
15s, 30s, 60s, continuous
LOW BATTE Y WA NING LED flash once every 30 seconds
FO M C D Y CONTACTS 0-30VAC/DC, 1 Amp
ATED FO Contacts reset after longest alarm setting
KEY SWITCH Alarm on: normally closed
ALA M SWITCH Stand by: normally open contact required
POLYCA BONATE UL94V-2
FLAMMABILITY ATING
14.2 in.
(360mm)
12.2 in.
(310mm)
BOTTOM VIEW
FRONT VIEW
6.44 in.
(164mm)
23.5 in.
(597mm)
16.5 in.
(419mm)
1/4”
DIAMETER

STEP 1 - MOUNTING OPTIONS
4
INSTALLATION OF ALARM
O
DRILL
3-/16 DIA HOLES
19018 ANCHOR
#8-10
(2) PROVIDED
19039 SCREW
#6 x 1 1/4 in.
(2) PROVIDED
BASE PLATE
18074 SWITCH LOCK
SUB-SA505 KEY SWITCH
MOUNTING BRACKET
3 9/32 in.
18075 REPLACEMENT
#801 KEY
O
TOKEY MOUNT PLATE O INTO WALL WITHOUT ELECT ICAL BOX
ENCLOSURE
ROUTE THE TWO KEY
SWITCH WIRES THROUGH
THE HOLE AS SHOWN
WIRE ACCESS HOLE
ROUTE THE TWO REED
SWITCH WIRES FROM
CABINET THROUGH THE
HOLE AS SHOWN
E
INSTALLATION OF CABINET
1. Insert the (4) 06298
mounting tabs fully into
backbox mounting tab
slots. Use rubber mallet if
necessary.
2. After selecting a suitable
location, place cabinet in
closed position, against the wall. Mark and drill (4) 1/4 in. diameter holes.
Insert the (4) 19033 anchors. Mount cabinet by driving in the four #10 x
1 1/2 in. screws.
3. For STI-7531AED select one of the two shelf mounting locations, install
shelf. Close and lock cabinet.
backbox mounting tab slot
mall
in closed position, against the wa
drill (4) 1/4 in. diamet
19033 anchors.
3
install shelf. Nex
through the acc
view A. Close and lock cabinet
wire
Drive in the (4) scre
of cabinet
optional mounting holes
diamet
mounting plat
drive the (2) alarm mounting scre
pre
the terminal switch diagram shown in view B.
4
scre
M
19033 ANCHOR
(4) PROVIDED
04875 MOUNTING PLATE
PROVIDED
19002 SCREW
#8-32 x 3/8 in.
(4) PROVIDED
OPTIONAL SHELF
MOUNTING POSITION
07530WR
ADJUSTABLE SHELF
INCLUDED WITH
STI-7531AED ONLY
07530 CABINET
ASSEMBLY
6297530
GASKET PROVIDED
06298
MOUNTING TABS (4) PROVIDED
19013 SCREW
#10 x 1 1/2 in.
(4) PROVIDED
MOUNTING
TAB SLOTS
STI-7530 KEYLOCK
STI-7531 AND
STI-7531AED THUMBLOCK
Note: Installation of cabinet
should be before
installation of alarm
because the mounting
bracket butts up to
cabinet.

5
1 0 0 0 0 0 BUZZ
2 1 0 0 0 0 SLOW ON/OFF
3 0 1 0 0 0 SLOW SI EN
4 1 1 0 0 0 3 BEEP/PAUSE/ EPEAT
5 0 0 1 0 0 UFO FAST
6 1 0 1 0 0 FAST SI EN
7 0 1 1 0 0 #5 FAST
8 1 1 1 0 0 #2 MEDIUM
9 0 0 0 1 0 #5 MEDIUM
10 1 0 0 1 0 SWOOP MEDIUM
11 0 1 0 1 0 #3 MEDIUM
12 1 1 0 1 0 BUZZ TONE
13 0 0 1 1 0 STEADY FAST
14 1 0 1 1 0 SWOOP SLOW
15 0 1 1 1 0 CONTINUOUS
16 1 1 1 1 0 FAST EPEAT
17 0 0 0 01 STANDA D ALA M
18 1 0 0 0 1 #3 FAST
19 0 1 0 0 1 #5 SLOW
20 1 1 0 0 1 FAST BEEP
21 0 0 1 0 1 SOUND A
22 1 0 1 0 1 SOUND B
23 0 1 1 0 1 SOUND C
24 1 1 1 0 1 SOUND D
25 0 0 0 1 1 SOUND D LOUD
26 1 0 0 1 1 SOUND E
27 0 1 0 1 1 SOUND F
28 1 1 0 1 1 SOUND G
29 0 0 1 1 1 SOUND H
30 1 0 1 1 1 #4 LOW
31 0 1 1 1 1 SOUND K
32 1 1 1 1 1 CONTINUOUS FAST
1
ALARM TIMING VOLUME
STROBE TIMING
ON
OFF
1
2345
0
15 seconds 11 11 High
30 seconds 10 10 1
60 seconds 01 01 Low
Continuous 00 00 0
1 = ON 0 = OFF
STEP 3 - ALA M TONES - S1
STEP 4 - ALA M TIMING AND VOLUME - S2
S1
ALARM TONE
S2
ALARM TIMING
STROBE TIMING
VOLUME
LED QTY 10
LOW BATTERY
INDICATOR LED
TERMINAL STRIP
TAMPER SWITCH
(REAR VIEW)
WIRE ENTRY
BATTERY
BATTERY CABLE
SIREN
O
O
1 2 3 4 5 1 2 3 4 5
ALARM
TIMING 1 2 3 4 5
VOLUME
STROBESIREN
*Factory default settings
*
*
STEP 2 - ELECT ONIC SETUP -
SELECT ALA M TONE AND TIMING SEQUENCE
NOTE: Select-Alert must be on a flat surface and lens must be
installed or the tamper switch will trigger the alarm.
NOTE: Sound may be disabled by clipping
wires to the siren. THIS WILL VOID ALL
WARRANTIES. Remove two screws on
circuit board; leave enough length of
wire to possibly reattach in the future.
Then insulate wires to prevent shorting
to electronic components.
O
WI ES TO SI EN

6
N
backbox mounting tab slots. Use rubber
mallet if necessa
in closed position, against the wall. Mark and
drill (4) 1/4 in. diameter holes. Insert the (4)
19033 anchors.
3
inst
through the access hole at See
view Close and lock cabinet.
4
wires are not pinched between the wall and cabinet.
Drive in the (4) screws. Cabinet is now secure.
I
of cabinet. Select at least two
optional mounting holes. Mark and drill 3/16 in.
diameter holes and inst
mounting plate and the siren backplate. Nex
drive the (2) alarm mounting screws into the
previous inst
the terminal sw
screws and provided tool.
1
05050- LENS COLORS
A - AMBER
B - BLUE
G - GREEN
R - RED
W - WHITE
19002 SCREW
#8-32 x 3/8 in.
(4) PROVIDED
ELECTRONICS
INSTALLED
BASE PLATE
WIRE ACCESS HOLE
19016 TAMPER-PROOF
TOOL (1) PROVIDED
19011 TAMPER-PROOF
SCREW
ROUTE WIRES
THRU HOLE
STEP 5 - ELECT ONICS ASSEMBLY
Wiring: After mounting circuit board assembly, connect wires. Refer to terminal strip connections (step 6).
Lens installation: Slide lip of lens behind circuit board mounting plate. Rotate lens into position. Secure with
tamperproof screw and special wrench. Unit will not operate properly if lens cover is not installed.
STEP 6 - TE MINAL ST IP CONNECTIONS
REMOTE POWER IN
12-24 VDC, 125mA
(OPTIONAL)
+-OFF ON
MAIN POWER
CONTROL TO
KEY SWITCH
STAND
BY
REED
SWITCH FROM CABINET
FORM "C"
DRY CONTACTS
NORMALLY OPEN
COM
+-
DCIN
KEY
SWITCH
ALARM
SWITCH
NC
COM
NO
NORMALLY CLOSED
ACTIVE
NOTE: “DC IN” are the only
polarity sensitive
terminals. When
external power is
used, battery will
act as a backup.
“Dry Contacts: NC,
COM, NO” are used
for remote alarm
monitoring.
!

7
STEP 7 - OPE ATION
• Turn key switch on to arm.
• Cycle key switch to reset alarm.
• Alarm will sound when cabinet is opened (alarm switch is electronically
closed), alarm cover is removed or unit is removed from the wall.
• To service, turn key switch off.
WA ANTY INFO MATION
• Three year guarantee against breakage of polycarbonate in normal use
(one year on electro mechanical and electronic components).
• Electronic warranty form at www.sti-usa.com/wc14.
ASSEMBLY PA TS LIST
1 05000 Electronics assembly (includes base plate & electronics assembly)
1 05050- ed lens (unless otherwise specified)
1 09723 Key switch mounting bracket
2 18075 #801 key
1 18074 Switch lock
1 18151 N.C. reed switch and magnet (installed in cabinet)
4 19002 Screw #8-32 x 3/8 in.
2 19039 Screw #6 x 1 1/4 in.
2 19018 Anchor #8-10
1 19011 #8-32 x 1/2 in. tamper screw
1 19016 Tamper wrench
1 BAT-9VDC 9 volt battery
SI EN/ST OBE ALA M
CABINET
1 07530 Hinged polycarbonate enclosure
4 06298 Mounting tabs
4 19013 #10 x 1 1/2 in. screw
4 19033 Plastic anchor
1 07530W Wire shelf (Included with AED models only)
1 04875 Mounting plate
4 19002 #8-32 x 3/8 in. screw
1 06297530 Gasket
1 07503 Thumb lock - STI-7535 models
1 18050 Key lock
2 18054 CH751 Key
}
STI-7534 models
QTY. PART # DESCRIPTION

Printed in USA SUBJECT TO CHANGE WITHOUT NOTICE Inst. Sht. STI-7535/STI-7535AED, JAN2014
2306 Airport Road
Waterford, Michigan 48327-1209
Phone: 248-673-9898 • Toll Free: 800-888-4784 • Fax: 248-673-1246
Safet Technolog International (Europe) Ltd.
Unit 49G Pipers Road • Park Farm Industrial Estate • Redditch
Worcestershire • B98 0HU • England • Tel: 44 (0) 1527 520 999
Fax: 44 (0) 1527 501 999 • Freephone: 0800 085 1678 (U only)
E-mail: [email protected] • Web: www.sti-europe.com
ACCESSO IES AND EPLACEMENT PA TS
AED-LBL AED label - 2 included (applied to sides of
cabinet; must be factory installed)
STI-SA5000- Replacement Siren/Strobe Alarm
18054 Replacement key for cabinet lock on STI-7534
18075 Replacement key for Siren/Strobe Alarm
07530W Wire shelf (included with AED models)
www.sti-usa.com
This manual suits for next models
2
Table of contents
Other STI Enclosure manuals