Stid SWEDGE User manual

© STid –MU_SWEDGE_V1.11_EN 1
User manual

© STid –MU_SWEDGE_V1.11_EN 2
Acknowledgment
Welcome in the world of the identification!
You have just purchased SWEDGE software.
We thank you for your trust and hope that this solution developed by STid will be to your entire
satisfaction.
We remain at your disposal for any question.
Do not hesitate to contact us on our web site www.stid.com for more information.
The STid team

© STid –MU_SWEDGE_V1.11_EN 3
ACKNOWLEDGMENT 2
1. INFORMATIONS 4
REQUIRED COMPUTER CONFIGURATION 4
USB KEY CONTENT 4
REQUIRED HARDWARE 4
INSTALLATION 6
STARTING SOFTWARE 7
2. SETTINGS 8
CHOICE OF THE READER TYPE 8
SERIAL PORT SETTING 8
SETTINGS PARAMETERS 9
3. READER CONFIGURATION 11
STR-R35-B/X03-5X AND STR-R32-B/X03-5X 11
STR-W15-A/E01-5G AND STR-W12-A/E01-5G 11
STR-W45-E/U04-5AA AND STR-W55-E/U04-5AA 12
STR-R35-E/PH5-5AB, STR-R32-E/PH5-5AB, ARC-R35-G/PH5-5AB, ARCS-R35-G/PH5-5AB
ET ARCS-R35-G/BT1-5AB 14
ARC-R35-L/LE2-5AB 16
ARC-W55-G/U04-5AA ET ARC-W45-G/U04-5AA 17
4. FORMAT SETTINGS 18
APPENDIX: COMMUNICATION PROTOCOL 20
ISO2 CLOCK&DATA PROTOCOLS 20
ISO 2B 20
ISO 2H 20
WIEGAND PROTOCOLS 21
WIEGAND 3CA 21
WIEGAND 3CB 21
WIEGAND 3LA 22
WIEGAND 3LB 22
WIEGAND 3I22
HISTORY REVISIONS 23

© STid –MU_SWEDGE_V1.11_EN 4
1. Informations
Required computer configuration
•Computer with Windows 7, 8 or 10 operating system
•USB or RS232 port
•50 Mo of free memory on hard disk
USB Key Content
•USB FTDI driver for Windows 7, 8 or 10.
•Swedge Version 1.4.x
Required hardware
•STid Desktop reader
✓USB
STR-R35-E/Ph5-5AB (13.56 MHz)
Or STR-R35-B/x03-5X (13.56 MHz)
Or ARC-R35-G/PH5-5AB (13.56 MHz)
Or ARCS-R35-G/PH5-5AB (13.56 MHz)
Or ARC-R35-L/Le2-5AB (13.56 MHz)
Or ARCS-R35-G/BT1-5AB (13.56 MHz & Bluetooth)
Or STR-W15-A/E01-5G (125 kHz)
Or STR-W45-E/U04-5AA (UHF)(ETSI)
Or STR-W55-E/U04-5AA (UHF)(FCC)
✓RS232
STR-R32-E/Ph5-5AB (13.56 MHz)
Or STR-R32-B/x03-5X (13.56 MHz)
Or STR-W12-A/E01-5G (125 kHz)
•USB or RS232+ power supply
•SWEDGE software

© STid –MU_SWEDGE_V1.11_EN 5

© STid –MU_SWEDGE_V1.11_EN 6
Installation
Insert the SWEDGE USB Key on an USB port of your PC.
Wait for the automatic opening of the browser window.
Launch SWedgeV14x_setup.exe .
Follow the instructions on the screen.
Connect the reader:
•In case of STR-W1x-A/E01-5G: the green LED will be lighted at the moment
of switching on.
•In case of STR-R3x-E/PH5-5AB: the orange LED will be lighted and the
buzzer activated at the moment of switching on.
•In case of ARC-R35-G/PH5-5AB: the white LED will be lighted and the
buzzer activated at the moment of switching on.
•In case of ARCS-R35-G/PH5-5AB: the white LED will be lighted and the
buzzer activated at the moment of switching on.
•In case of ARCS-R35-G/BT1-5AB: the white LED will be lighted and the
buzzer activated at the moment of switching on.
•In case of ARC-R35-L/Le2-5AB: the white LED will be lighted and the buzzer
activated at the moment of switching on.
•In case of STR-W45-E/U04-5AA and STR-W55-E/U04-5AA: the orange LED
will be lighted at the moment of switching on.
•In the case of the ARC-W55-G/U04-5AA, ARC-W45-G/U04-5AA enrollers/encoders:
their white LED will light up and their buzzer will sound for 2 seconds as soon as
they are switched on. Make sure there are no tags nearby while connecting and
setting up this reader.

© STid –MU_SWEDGE_V1.11_EN 7
Starting software
SWEDGE allows keyboard emulation when a tag is presented to the reader and a
formatting of it according the parameters of the software.
Caution
The Caps Lock key must be enabled.
OR
Warning
If you do not have administrator rights, you must execute
SWEDGE with
”Run as administrator”.

© STid –MU_SWEDGE_V1.11_EN 8
2. Settings
Choice of the reader type
Gamme A
Gamme type B, E, G & L
STR-W15-A/E01-5G
STR-R35-E/Ph5-5AB
ARC-R35-G/PH5-5AB
STR-W12-A/E01-5G
STR-R35-B/x03-5X
ARC-R35-L/Le2-5AB
STR-W45-E/U04-5AA
ARCS-R35-G/PH5-5AB
STR-W55-E/U04-5AA
ARCS-R35-G/BT1-5AB
STR-R32-E/Ph5-5AB
STR-R32-B/x03-5X
ARC UHF
ARC-W55-G/U04-5AA
ARC-W45-G/U04-5AA
Serial port setting
The communication between the software and the reader is done through a serial port (USB or
RS232). To do the configuration, please press this button « ».
You can download new driver on http://www.ftdichip.com/Drivers/VCP.htm.
Caution
It is important to install the USB driver provided with the software in the CD.
Default baudrate for readers:
9600 bauds
115 200 bauds
STR-R35-E/Ph5-5AB
STR-W45-E/U04-5AA
STR-R35-B/x03-5X
STR-W55-E/U04-5AA
ARC-R35-G/PH5-5AB
ARC-W55-G/U04-5AA
ARC-R35-L/Le2-5AB
ARC-W45-G/U04-5AA
ARCS-R35-G/PH5-5AB
ARCS-R35-G/BT1-5AB
STR-W15-A/E01-5G
STR-W12-A/E01-5G
STR-R32-E/Ph5-5AB
STR-R32-B/x03-5X

© STid –MU_SWEDGE_V1.11_EN 9
Settings parameters
Start with system
Activate the opeming of the application at system startup.
Auto run
Automatic execution of the application at opening the software
with the parameters saved in the ini file.
Hide when
working
By checking this box the application will be hidden in the taskbar.
Beep after every
read event
Activate beep after each identifier reading.
Caps Lock
Activate caps locks.
UserProfile Unchecked box:
The settings file Swedge.ini is saved in the directory containing the
executable, by default: C:\Program Files (x86)\STid\SWedge v1.3.x.File
content:
[SWEDGE]
UserProfile=0
ComPort=COM10
ComBaudrate=115200
ReaderType=0
HexDec=0
Truncate=0
Size=32
CRLF=0
MSB=0
AntiRep=0
AntiRepTimeout=0
AutoStart=0
AutoRun=0
HideWhenWorking=0
Beep=0
CapsLock=0
EditAddCharLeft=0
EditAddCharRight=
Protocol=0

© STid –MU_SWEDGE_V1.11_EN 10
Checked box:
Warning: SWEDGE must be run in administrator mode to activate this
option.
The settings file Swedge.ini is save in the user:
C:\Users\username\STid\Swedge\Swedge.ini. File content:
[SWEDGE]
ComPort=COM10
ComBaudrate=115200
ReaderType=0
HexDec=0
Truncate=0
Size=32
CRLF=0
MSB=0
AntiRep=0
AntiRepTimeout=0
AutoStart=0
AutoRun=0
HideWhenWorking=0
Beep=0
CapsLock=0
EditAddCharLeft=0
EditAddCharRight=
Protocol=0

© STid –MU_SWEDGE_V1.11_EN 11
3. Reader Configuration
If the reader was not purchased in a kit SWEDGE, it is necessary to configure it to work with the
software.
STR-R35-B/x03-5X and STR-R32-B/x03-5X
These readers require no special configuration before use with SWEDGE. The reader reads the chip
serial number in hexadecimal and sends it to SWEDGE on UID tag format.
STR-W15-A/E01-5G and STR-W12-A/E01-5G
The factory default parameters of these readers are read/write. To work with SWEDGE, they must
be set to standalone. To do this, commands must be sent using a HyperTerminal.
Operating procedure:
•Open an Hyperterminal
•Connect the reader to configure
•Set the communication port:
oPort COM number
oBaudrate 9600 bds
oBits: 8
oStop Bit 1
oParity: none
•Send the three commands (hexadecimal value):
o\02\20\04\00\00\24\03 reader answer: \02\20\00\00\20\03
o\02\2E\01\00\00\2F\03 reader answer: \02\2E\00\00\2E\03
o\02\22\01\00\00\23\03 reader answer: none
•Checking: present a 125 KHz card on the reader, it must read continuously (beeps).
The reader reads the chip serial number (EM410x default chip) in hexadecimal and sends it to
SWEDGE on a 40 bits frame (5 bytes).

© STid –MU_SWEDGE_V1.11_EN 12
STR-W45-E/U04-5AA and STR-W55-E/U04-5AA
The factory default parameters of these readers are read/write. To work with SWEDGE, they must
be set to standalone.
We must send commands using an HyperTerminal or using the application SESpro.
Operating procedure to read EPC:
•Open an Hyperterminal
•Connect the reader to configure
•Set the communication port:
oPort COM number
oBaudrate 115200 bds
oBits : 8
oStop bit: 1
oParity: none
•Send the commands below (hexadecimal value) :
Command 1
<02><00><09><00><00><00><00><00><05><AA><55><00><01><00><E5><55>
Answer 1
<02><00><06><00><00><00><05><00><00><00><00><98><E6> + beep lecteur
Command 2
<02><00><48><00><00><00><00><00><22><AA><55><00><40><00><1E><08><20><00><00><00><00>
<00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00
><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><00><0
0><00><00><00><00><00><00><00><00><00><00><00><00><00><00><B1><F8>
Answer 2
<02><00><06><00><00><00><22><00><00><00><00><F7><86>
Command 3
<02><00><09><00><00><00><00><00><25><AA><55><00><01><01><C0><7C>
Answer 3
<02><00><06><00><00><00><25><00><00><00><00><90><52>
Command 4
<02><00><0B><00><00><00><00><00><12><AA><55><00><03><62><01><0C><03><A7>
Answer 4
<02><00><06><00><00><00><12><00><00><00><00><FB><68>
Command 5
<02><00><08><00><00><00><00><00><10><AA><55><00><00><15><CE>
Answer 5
<02><00><06><00><00><00><10><00><00><00><00><BF><EB> + beep lecteur
•Checking: present an EPC1 GEN2 card on the reader, it must read continuously (beeps).
The reader reads the chip serial number in hexadecimal and sends it to SWEDGE on a 96 bits frame
(12 bytes).

© STid –MU_SWEDGE_V1.11_EN 13

© STid –MU_SWEDGE_V1.11_EN 14
STR-R35-E/PH5-5AB, STR-R32-E/PH5-5AB, ARC-R35-G/PH5-5AB, ARCS-R35-G/PH5-
5AB et ARCS-R35-G/BT1-5AB
These readers are configurable with configuration card create with SECard.
Below are the parameters to select in SECard to configure the reader for operation with
SWEDGE:
•Select the type of reader R32 or R35
•Serial settings

© STid –MU_SWEDGE_V1.11_EN 15
•Configuring chip data to read: either UID in this case select for all chips UID and MSB First,
either Private ID.

© STid –MU_SWEDGE_V1.11_EN 16
ARC-R35-L/Le2-5AB
These readers are configurable by serial link with SEGiC.
Below are the parameters to select in SEGIC to configure the reader for operation with SWEDGE:
•Select the type of reader R35
•Reader communication protocol

© STid –MU_SWEDGE_V1.11_EN 17
ARC-W55-G/U04-5AA et ARC-W45-G/U04-5AA
These readers are configurable in SWEDGE by selecting the Reader Type: ARC UHF then
clicking on the ARC UHF Parameters button.
Make sure there are no tags near the reader during the setup phase.
SWEDGE Enroller mode is the main mode of use with SWEDGE software.
The " Encoder " mode allows to switch the reader to write mode for use with STid's SESPRO and
ULTRYS v2 softwares.
SWEDGE offers the ability to upload secure tag IDs (EPCs), which have been encoded with
ULTRYS v2 and encrypted with a 16-byte private key.
To enable SWEDGE to read and display these encrypted tags, simply select the "Enciphered"
option, and fill in the 16-byte private key.
The "Apply" button allows to apply the defined parameters to the reader (choice of "SWEDGE
enroller" or encoder mode and choice of EPC the secure mode).

© STid –MU_SWEDGE_V1.11_EN 18
4. Format settings
Protocol Custom
All parameters are to be set.
Choose the data type decimal or hexadecimal.
If activated, SWEDGE will do a return after each
reading.
If activated, SWEDGE not return the read code as it
will be identical to the preceding and during the
timing sets.
Selects if the SWEDGE truncates the data before
decimal conversion or after (only available if the data
type selected is DEC).
If activated, SWEDGE truncates MSB first instead LSB.
Size of the ID. In bits or in digits according the
configuration.

© STid –MU_SWEDGE_V1.11_EN 19
Predefined Protocol
The setting for the most common protocols has been predefined.
26-bits Wiegand –3i: Site code and card code are displayed in decimal and concatenated into the
text field.
Example: Card encoded with site code 001 et card code 255
For Wiegand 3i, Clock&Data 2H and 2B, the field Truncate is configurable to the needs.
Supplement by Left or Right
Used to force character(s) before or after the data to read.
Previous example with forced AA before:

© STid –MU_SWEDGE_V1.11_EN 20
APPENDIX: Communication protocol
ISO2 Clock&Data protocols
ISO 2B
Reading tag on 5 bytes (40 bits) and decimal conversion.
Example:
For a hexadecimal ID “0x187E775A7F”, number will be “0105200966271”.
The frame sent by the reader will be:
000...
1101 0
0000 1
1000 0
0000 1
1010 1
. . . .
0110 1
0100 0
1110 0
1000 0
1111 1
1111 1
000...
B
0
1
0
5
2
0 09
6
6
2
7
1
F
F
Zeros
S.S
Car.1
Car.2
Car.3
Car.4
Car….
Car.10
Car.11
Car.12
Car.13
E.S
LRC
Zeros
ISO 2H
Reading tag on 4 bytes (32 bits) and decimal conversion.
Example:
For a hexadecimal ID “0x06432F1F”, number will be: “0105066271”.
The frame sent by the reader will be:
Variant
Format
Frame on 112 bits
Values
2B
Decimal (BCD)
13 characters
0 - 9
Variant
Format
Frame on 97 bits
Values
2H
Decimal (BCD)
10 characters
0 - 9
000...
1101 0
0000 1
1000 0
0000 1
1010 1
. . . .
0110 1
0100 0
1110 0
1000 0
1111 1
0010 1
000...
B
0
1
0
5
0
6
6
2
7
1
F
4
Zeros
S.S
Car.1
Car.2
Car.3
Car.4
Car….
Car.7
Car.8
Car.9
Car.10
E.S
LRC
Zeros
Table of contents
Other Stid RFID System manuals