EDIT
MODE
Tocreate or change a SL-1100preset, itisnecessary to enter Edit Mode. Mostofthe parameters
in the preset are associated with one ofthe four keyboard zones. Theprocedure for changing .
any ofthese zone parameters isasfollows:
1)Enter Edit Mode by pressing and holding one ofthe four ZONE switches.
2)Press the FUNCTION switch which islabeled with the desired parameter.
3)Release both switches. The ZONE switch will blink to indicate that itsparameters are
-editable.Pressing any FUNCTION switchrepeatedly will cyclethrough the three parameters
available on the switch. ^
4)Change the current value with the CSL/DATA slider.
5)Press the blinking ZONE switch to exitEdit Mode.
There isno Store function on the SL-1100;any parameter that was changed in Edit Mode is
automatically updated in internal memory. Note that the Zone switches must bein the desired
state before entering edit mode. Theseare the settings that will bestoredinto the presetupon
returning to Perform Mode. To change the stored Zone switch settings for a preset, setthe
Zones asdesired, and enter Edit Mode using any combination ofa Zone switch and a Function
switch. Press the blinking switch to exit Edit Mode, and the new Zone settings will be saved.
ZONE
FUIMCTIOMES
Each keyboard zone on the SL-1100has severalparameters which must besetto accessthe
desired sound from the sound module. The following sectionsdescribe the purpose ofeach.
zone function. <
LOWKEY
HIGHKEY
These functions are used to setthe range ofactivekeys for the zone. Tosetthe lowestactive
key, press and hold the desiredZONE switch. Press the FUNCTION 1 switch, then release both
switches. The Zone switch will blink, and the LED display indicates the lowestactive key. Use
the DATA slider to seta new value. Toset the highest active key, press FUNCTION switch 1
again. The LED display now willindicate the highest active key which may be changed with the
DATAslider.Pressthe blinking switch to exitthe edit mode.
For convenience, an alternate programming method isavailable which isfaster than setting the
key limits with the slider. First press and hold the ZONE switch to be edited. Press the
FUNCTION 1 switch. Release both switches. The ZONE switch will now blink, and the LED
will display the lowestactive key. Play two keys on the keyboard (theorder doesnot matter) to
program the new lowand high keys. The Edit mode willterminate automatically.
PROGRAM
The Program function isused to issue a MIDI program change command at the instant a SL-1100
preset isselected. The Program number issetindependently for each ofthe four keyboard
zones. To setthe MIDI program, press and hold the desired ZONE switch, and press the
FUNCTION 2 switch. Release both switches. The ZONE switch will blink. The display will
indicate the MIDI program ( 1 through 128).Change the setting with the DATA slider (the
program change commands will be issued asthe slider ismoved). Ifno program change is
desired selectthe dash (-).Press either blinking switch to exitthe edit mode.
For convenience a special Program Change function isavailable from Perform Mode. Pressand
hold a ZONE switch, then simply enter the program number (1through 128)on the labeled
black keys (the digitswill appear on the display asthey are entered). When the ZONE switch is
released, the entered program number will be issued on the channel corresponding to the zone.
The current MIDI Bank number may be selected in a similar fashion. Press and hold a ZONE
switch, then momentarily press the black BANK key. Enter the desired bank on the numbered
black keys. A Bank Selectmessage will beissued when the ZONE switch isreleased.