1. Pairing (g. 7-9)
The AquaPlug/AquaPanel has built-in a memory of which pump it was paired to last time. This is done to ensure that the unit
will find the correct pump if a power failure occurs on more than one pump in an installation.
There are two time-outs in the system.
1. Pairing time-out: which means that if pairing does not occur in one minute the AquaPlug/AquaPanel will not continue to
search for a pump. This is done to ensure that the unit will not pair with and control a “foreign” pump.
2. Power time-out: this means that a pump will not pair with a unit which has been powered for a shorter time than itself.
This is done to ensure that the AquaPlug/AquaPanel takes control of the pump it was plugged in with.
If pairing has not been successful it can depend on:
1. Occasional disturbance on cable – try to make pairing once again.
2. Constant disturbance on power line. Can be caused of other electrical devices such as frequency converters. If this is
the case, try to put an extension cable of more than two metres between power source and AquaPlug/AquaPanel (this
will give enough resistance to filter most disturbance away).
If none of above tests will work try to use a dierent power supply.
NOTE! Do not disassemble the AquaPlug / AquaPanel.
2. Energy save mode (g. 10-12)
The pump can run with an AquaPlug/AquaPanel in energy save mode (when blue button is activated).
When connected with a level sensor measuring probe, the level of water is detected and the pump starts when water is
touching the probe. It will automatically be stopped when the water level is beneath the hydraulic parts. The pump starts
again when water touches the sensor.
3. Alarm and warning limits (g. 13-15)
Alarm signal
(pump stops)
Warning signal
(pump continues to run)
Limit Symbol
Overload warning light:
winding high temperature. 140 ºC Red
Overload warning light: AquaTronic
high temperature.
Soft start 80 ºC
DOL (Direct-On-Line)s 110 ºC Red
Overload warning light: high amp. By curve +20 % at long time
overload. Red
Power warning light: phase missing
(under voltage). -15 % Red
Power warning light:
phase unbalance. ±20 % Red
Service warning light: seal leakage. 50 kohm Yellow
Service warning light: bad motor
insulation. 100 kohm Yellow