manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. Summit
  6. •
  7. Scale
  8. •
  9. Summit S6600 User manual

Summit S6600 User manual

IN-0913 5012A
S6600
OPERATOR’S MANUAL
●
SET FUNCTIONS
The scale can be set as desired for the user. The settings that can
be changed are:
Weighing Units enabled
Time delay before the scale automatically turns off.
Access to some service parameters, Contact your dealer for
more details.
Press and hold the TARE key for 3 seconds until the display
shows “Set” then the first menuoption“Unit”
Press the Unit key to cycle through the options.
At each option press theHold key to enter the functions and then
press the Unit key to see the options, pressing the Hold key
again to return to the functions menu.
Each weighing unit can be enabled or disabled
The Automatic Turn-off time can be set or disabled (off)
The other functions do not apply to the users. Advance to
in order to exit the menu.
4
TABLE OF CONTENTS
Introduction/Specification …………………………………………2
Power Supply ……………………………………………………… 2
Operator’s Instructions.……………………………………………3
Display Symbols …………………………………………………….3
Set Functions... ………………………………………...…………….4
Service Address ……… …………………………………………….5
1
kg Lb Oz.
Unit
On
Off
On
Off
On
Off
A.Off
120
180
240
300
Off
End
SEt
Unit
A.Off
CAP
GrAv
trAn
END
CAL
divS tr
●
INTRODUCTION
All scales come complete with plastic cover and base, a large LCD display,
which is easy to read.
The water-resistant keyboard has 4 easy to use function keys: HOLD,
UNIT, ON/ZERO/OFF, TARE.
With the standard AC adaptor included and rechargeable batteries, the
scales can be used in a fixed location or as a portable scale.
●Power
Power can be supplied by mains adaptor and delivering a regulated
switching adaptor. (Input: 120V, output: 15V 300mA) Using batteries inside
of scale’s head (rechargeable battery 7.2V 1200mAH).
SPECIFICATIONS
Model # S6600
Maximum Capacity 660 lbs. / 300 kg
Graduation 0.2 lb / 0.1 kg
Resolution 1: 3000
Tare Range Full range
Repeatability (STD Dev) +/-1d
Linearity ± +/-2d
Units of Measure Kg/lb/oz
Stabilisation Time 1-2 sec.
Operating Temperature 5°C –35°C or 13 F -95°F
Power supply Rechargeable batteries or AC adaptor
Indicator display 1.5” LCD digital display
Dimensions (w x d x h) 15.5x12.5x3.3 inch
Gross Weight 7.7 lb / 3.5 Kg
2
lOPERATOR’S INSTRUCTIONS
Key description
Tare -Set the display to zero by storing the
current weight in the tare memory
On / Zero / Off -Turns the scale on, zero or off,
Units -Select kilograms, pounds or ounces
Hold -Temporarily memory the weight.
Place an item to be weighed on the platform. Press
HOLD key, the arrow of the left bottom will blink.
The display shows the measured weight.
After removing the item, the display still shows the
weight.
Press HOLD or TARE button to disable HOLD
function.
Turn the scale on using the On/Zero/Off key. After the display is at
zero, place an item to be weighed on the platform. The display will
show the weight. The unit will be shown in kilograms unless the user
has selected either pounds or ounces previously.
If an empty container is used the weight can be ignored by zeroing the
display. To zero the display press the TARE key. Then when material
is placed in the container only the weight of the material will be shown.
DISPLAY SYMBOLS
Symbol Description
è¡çscale in auto zero range (indication = accurate zero)
¡result is stable
kg , lb or oz scale in weighing mode
Lo-bAt Battery is weak, after 5 minutes the scale will turn off
Show the Net Weight is being display (NW) or the Gross
Weight is displayed (GW)
3
FOR SERVICE: CONTACT YOUR LOCAL DISTRIBUTOR
5
Manufacturer’s Declaration of Conformity
This product has been manufactured in accordance with the
harmonized European standards, following the provisions of the
below stated directives:
Electro Magnetic Compatibility Directive 89/336/EEC
Low Voltage Directive 73/23/EEC
SUMMIT

Other Summit Scale manuals

Summit S4600 User manual

Summit

Summit S4600 User manual

Summit 3000 User manual

Summit

Summit 3000 User manual

Summit S3900 User manual

Summit

Summit S3900 User manual

Popular Scale manuals by other brands

Weight Watchers WW89C Instructions for use

Weight Watchers

Weight Watchers WW89C Instructions for use

inventum WS305B instruction manual

inventum

inventum WS305B instruction manual

Scarlett SC-BS33ED45 instruction manual

Scarlett

Scarlett SC-BS33ED45 instruction manual

Luvion Deluxe exact-75 user manual

Luvion

Luvion Deluxe exact-75 user manual

Sartorius BL310 instruction manual

Sartorius

Sartorius BL310 instruction manual

BREWISTA Smart Scale II manual

BREWISTA

BREWISTA Smart Scale II manual

Rowenta PREMISS BS14 Series quick start guide

Rowenta

Rowenta PREMISS BS14 Series quick start guide

Atlanta ATH-6198 instruction manual

Atlanta

Atlanta ATH-6198 instruction manual

OMEGAbilance Freestyle user manual

OMEGAbilance

OMEGAbilance Freestyle user manual

Gallet GALBAC 927 instruction manual

Gallet

Gallet GALBAC 927 instruction manual

Beurer KS 22 Instructions for use

Beurer

Beurer KS 22 Instructions for use

UWE VOC Series Operation manual

UWE

UWE VOC Series Operation manual

Gram SPX 600D Operation manual

Gram

Gram SPX 600D Operation manual

KERN DS 3K0.01S operating instructions

KERN

KERN DS 3K0.01S operating instructions

KERN TEE operating instructions

KERN

KERN TEE operating instructions

Oregon Scientific GR101H user manual

Oregon Scientific

Oregon Scientific GR101H user manual

OHAUS Valor 1000 instruction manual

OHAUS

OHAUS Valor 1000 instruction manual

SCALIX FEJ-5000 instruction manual

SCALIX

SCALIX FEJ-5000 instruction manual

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.