Sunpak Infrared Heater 2
Model S34-TSH
Sunpak S34-TSH
The Sunpak S34-TSH outdoor heater provides radiant heat with both a high and low heat
setting. This non-remote control heater is hardwired making it easily adaptable for single and
multi-heater installations where a central system control panel is used.
The Sunpak S34-TSH two stage heaters are easily controlled using a duplex switch such as the
Leviton switch No. 5634. The switch must be wired according to our diagram to work properly. A
24 VAC Class 2 transformer is required to supply electrical to heater.
Figure 1. A 24 VAC 20 VA Class 2 Transformer
with a UL/CSA listing is required for each heater.
Available from your local distributor. Transformer is
to be supplied by installer.
Figure 2 Dual switch panel controls OFF/ON
and HI/LO functions on Sunpak Module S34-
TSH.
Initial Power-up of Sunpak S34-TSH
Once the heater has been mounted properly, the clearance from combustible material verified
and the gas and electric power hooked up you are ready to POWER-UP. See Sunpak Instruction
#65132 for details.
POWER-UP
Always start the Sunpak heater on the high setting. Once the heater is at full heat, the low
setting can be used.
Note: There is a 5 second delay before the heater powers up.
Press the ON switch to start the ignition sequence. The spark will initiate within 5 seconds
followed by the ignition of the pilot. If the pilot fails to ignite after 10 seconds the gas and spark
will shut off. The pilot will try to light 3 times before lockout.
NOTE: If the burner fails to ignite you must wait 5 minutes before attempting to relight the
heater.
To reset the heater, turn the heater switch OFF. Turning the heater switch back ON will restart
the ignition sequence.