manuals.online logo
Brands
  1. Home
  2. •
  3. Brands
  4. •
  5. SUNSET
  6. •
  7. Ultrasonic Jewelry Cleaner
  8. •
  9. SUNSET ZOEY ZCD100 User manual

SUNSET ZOEY ZCD100 User manual

You will be using this
connector, found inside
once you open Zoey:
↑
C
P
A
P
↑
↑
C
P
A
P
↑
Push down
on the press
point until
it clicks and
opens lid.
Remove tube connector from
tray. Attach tube connector to
CPAP machine.
Do not attach to Zoey.
Disconnect CPAP tube from
your CPAP machine and mask
Before first time use, it is recommended to hand wash your CPAP equipment according to manufacturer's
instructions, as you would normally without Zoey. This removes debris, and prevents oxidation odors from
occurring in your CPAP equipment after running the Zoey cleaning cycle. When using Zoey regularly, you'll only
need to hand wash your CPAP equipment as needed.
2
3
3
4
3
8
7
6
910
11
12
5
Zoey
rear
corner
Click
Connect CPAP tube cuff all the way onto
Zoey's CPAP tube connector, in order
to press in and trigger the CPAP
tube sensor. The CPAP tube
sensor should be firmly held
in place by the CPAP tube cuff.
!
?
1
Instruction Manual
CPAP Cleaner
Additional resources
CleanWithZoey.com
/videos
How-to videos
CleanWithZoey.com
General information
Support@
CleanWithZoey.com
Email us with your
questions or feedback
Call
1-888-990-4385
Call us if you'd like to
talk to someone
Done!
When all three lights display solid
green, the cycle is complete and it is
safe to open Zoey. Remove CPAP tube
while lid is open to turn off lights.
This section
can remain
in place at all
times—whether
you're cleaning with
Zoey or using
your CPAP.
Press the power button on Zoey to start cleaning cycle.
When the rst light turns blue, you may walk away and
let Zoey clean. It is important to keep Zoey closed during
the entire cycle — normally 2 hours.
If three red lights are displayed, your CPAP tube may not
be triggering Zoey's CPAP tube sensor (see step 10).
Also, ensure Zoey's lid is fully clicked shut.
Refer to the enclosed instruction
manual for troubleshooting and
more information
You may need an additional adapter if you
use a heated tube on your CPAP machine.
Visit CleanWithZoey.com/adapters
for more info.
ZCD100 Quick Start Guide V 3.00
2020-08-04
Click
CPAP tube
sensor
Quick Start Guide
Option 1
Instructions for Option 2
are on the flip side!
Option 2
Option 1
You'll also find
this adapter, but
you won't need it.
or...
Clean your:
1 CPAP machine
2 Mask
3 Tube
Clean just your:
1 Mask
2 Tube
1
1
2
2
3
You choose!
You will be using this adapter,
found inside once you
open Zoey:
↑
C
P
A
P
↑
Push down on the press point until it
clicks and opens lid.
Remove ozone
plug adapter from
the tray and
connect to Zoey's
injection tube.
Disconnect CPAP tube
from your CPAP machine
and mask
Before rst time use, it is recommended to
hand wash your CPAP equipment according
to manufacturer's instructions, as you would
normally without Zoey. This removes debris, and
prevents oxidation odors from occurring in your CPAP
equipment after running the Zoey cleaning cycle.
When using Zoey regularly, you'll only need to hand
wash your CPAP equipment as needed.
2
34
78
5
6
9
10
11
12
Zoey
rear
corner
Click
Connect other end of CPAP tube all the
way onto Zoey's CPAP tube connector, in
order to press in and trigger the CPAP tube
sensor. The CPAP tube sensor should be
rmly held in place by the CPAP tube cuff.
Connect ozone plug adapter
to one end of your CPAP tube.
!
?
1
Instruction Manual
CPAP Cleaner
Additional resources
CleanWithZoey.com
/videos
How-to videos
CleanWithZoey.com
General information
Support@
CleanWithZoey.com
Email us with your
questions or feedback
Call
1-888-990-4385
Call us if you'd like to
talk to someone
Done!
When all three lights display solid
green, the cycle is complete and it is
safe to open Zoey. Remove CPAP tube
while lid is open to turn off lights.
Press the power button on Zoey to start cleaning cycle. When
the first light turns blue, you may walk away and let Zoey
clean. It is important to keep Zoey closed during the entire
cycle — normally 2 hours.
Refer to the enclosed instruction
manual for troubleshooting and
more information
CPAP tube
sensor
If three red lights are displayed, your CPAP
tube may not be triggering Zoey's CPAP
tube sensor (see step 10).
Also, ensure Zoey's lid is fully clicked shut.
A standard CPAP tube is shown, but
you may also use a heated CPAP tube.
Visit CleanWithZoey.com/tubes
for guidance.
ZCD100 Quick Start Guide V 2.00
2020-03-24
Click
Instructions for Option 1
are on the flip side!
Quick Start Guide
or...
Option 2
You'll also find
this connector, but
you won't need it.
Option 1
Option 2 Clean your:
1 CPAP machine
2 Mask
3 Tube
Clean just your:
1 Mask
2 Tube
1
1
2
2
3
You choose!

Popular Ultrasonic Jewelry Cleaner manuals by other brands

Probuilder 16937 instruction manual

Probuilder

Probuilder 16937 instruction manual

Kränzle Round Cleaner 300 INOX Operating manual with spare parts list

Kränzle

Kränzle Round Cleaner 300 INOX Operating manual with spare parts list

RIDGID 36023 manual

RIDGID

RIDGID 36023 manual

JOCCA 1249 instruction manual

JOCCA

JOCCA 1249 instruction manual

Kärcher FC 7 Cordless quick start guide

Kärcher

Kärcher FC 7 Cordless quick start guide

Connoisseurs SafeWave LaSonic quick start guide

Connoisseurs

Connoisseurs SafeWave LaSonic quick start guide

Kärcher SB OB manual

Kärcher

Kärcher SB OB manual

Laser 6166 instruction manual

Laser

Laser 6166 instruction manual

poolstar NetSpa Super Vac user manual

poolstar

poolstar NetSpa Super Vac user manual

Hammerhead DCFSCP18 Operator's manual

Hammerhead

Hammerhead DCFSCP18 Operator's manual

Rothenberger RODIA 1600 Instructions for use

Rothenberger

Rothenberger RODIA 1600 Instructions for use

Hedson DRESTER X Series Operation manual

Hedson

Hedson DRESTER X Series Operation manual

ETEKCITY CD-2800 user manual

ETEKCITY

ETEKCITY CD-2800 user manual

MaxVac DV15 MB instruction manual

MaxVac

MaxVac DV15 MB instruction manual

Makita DVC560 instruction manual

Makita

Makita DVC560 instruction manual

Forch INOX CLEANER 350 W manual

Forch

Forch INOX CLEANER 350 W manual

IPC ML 15.150 TST manual

IPC

IPC ML 15.150 TST manual

Maximex 9935390500 Instructions for use

Maximex

Maximex 9935390500 Instructions for use

manuals.online logo
manuals.online logoBrands
  • About & Mission
  • Contact us
  • Privacy Policy
  • Terms and Conditions

Copyright 2025 Manuals.Online. All Rights Reserved.