SunStone Power SLPO12-100 User manual

LITHIUM BATTERY PACK
USER MANUAL
MODEL: SLPO12-100
※Please read this manual before using the battery pack
※Please keep this manual properly after reading

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
1. Product key parameters
NO. Specification
Item
14.4V±0.2V
12.8V
10V
100Ah (After standard charging, discharging at 0.5C.)
100Ah (After standard charging, discharging at 0.5C.)
Step 1: 50A constant current charge to 14.4V;
Step 2: 14.4V constant voltage charge until the charging current reaches
5A.
Temp.:0~45°C
2.5hours (for reference)
100A
100A
Charging: 0~45°C; Discharging: -20~55°C
1month: -20~45°C
3 months: -10~45°C
6 months: 0~25°C
humidity: 45~90% RH
The battery should be cycled every three months.
After 6000 cycles, at 25°C, 50A charge and discharge 80% DOD,
recoverable capacity ≥ 80%
≤ 100mΩ(50% capacity,AC impedance 1kHz measuring)
About 12kg
13~13.8V
320(L)*172(W)*130(H)mm
Bluetooth, LED display and dual USB 5V/2.1A
Grey
1.2
1.3
1.4
1.5
1.6
1.7
1.8
1.9
1.10
1.11
1.12
1.13
1.15
1.16
1.17
1.18
1.19
Charging voltage
Nominal voltage
Cut-off voltage
Nominal capacity
Min. capacity
Standard charging
current and voltage
Charging time
Max charging current
Max. discharge current
Working Temp.
Storage Temp. and
humidity range
Cycle life
Battery weight
Ex-work voltage
Dimension
Function
Color
Initial battery
internal resistance
1.1
1.14
Appearance The battery pack surface is clean, free from scratches and mechanical
damage.

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
2. Structural characteristics and interface function
2.1 Basic structure
Fireproof plastic ABS+PC.
2.2 Installation method
Professional sealant seal.
2.3 Over structure
The battery pack is mainly composed of the following parts: a plastic case, which contains a 4S
module inside, accessories including BMS, plug column, dual USB interface, display screen. The
overall structure is simple, high reliability, light weight and high energy density.
2.4 External interface function
⑥
②
⑤
④
①
③

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
2.4.2 Battery pack interface functions
(1) The positive and negative terminals of the battery pack
The red terminal is the positive electrode of the battery, and the black terminal is the negative elec-
trode of the battery. Use M8 screws to lock it tightly. When installing, use SC25-8 copper nose to
connect external equipment for energy supply or charging.
(2) Screen display
The screen shows a total of 4 interfaces:
1. Current voltage value;
2. Current current value;
3. Current SOC;
4. Fault code (not displayed when there is no fault).
The meaning of the letters displayed on the screen: U stands for voltage, A stands for current
(charge and discharge current), and C stands for current power.
For example: 12U is 12V voltage; 50A is 50A current; 70C is 70% of current power.
When the screen 4 displays the fault code, the user can check the cause of the fault through the
following table.
2.4.1 Battery pack interface definitions
Function
Charge and discharge positive terminal
Charge and discharge negative terminal
Battery pack information and status display
Battery pack status guidelines
Battery pack on/off and status switch
External 5V output
Interface
Positive electrode
Negative electrode
Screen display
Indicator light
Switch
USB
Remark
-
-
-
Dual
Support continuous 100A
single pin overcharge
Support continuous 100A
single pin overcharge
NO.
1
2
3
4
5
6

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
Remark:
The normal operation level is Normal, the first level of alarm is Alarm, and the second is Protec-
tion. It cannot be charged or discharged during the Protect process. Charging and discharging
should be resumed after the normal threshold is restored(Refer to Item 3. BMS protection threshold).
(3) Indicator light
The battery pack indicator light is divided into red and green states: the green light flashes to indi-
cate that the battery is normal; the red light flashes to indicate battery self-test alarm or failure.
When the red light is flashing (Except for self-check status when power-on), please check the fault
code on page 4 of the display screen to get the cause of the fault.
(4) Switch
The user can control the battery switch and adjust the display screen content through the switch.
Power on:
①Long press the switch until the red light turns on (first the green light turns on, but the switch
shouldn’t be released).
②The system self-checks when the red light is flashing (about 10S). After that, the battery will enter
the power-on state.
Error code
E11
E21
E31
E41
E51
E61
E71
E81
E83
E91
E101
E111
E121
Meaning
Module equipment failure level 1 alarm
Module communication abnormal level 1 alarm
Module address abnormal level 1 alarm
Module balance abnormal level 1 alarm
Module overvoltage level 1 alarm
Module undervoltage level 1 alarm
Module charging overcurrent level 1 alarm
Module discharging overcurrent level 1 alarm
Module discharging load short circuit (serious)
Single cell overvoltage level 1 alarm
Single cell undervoltage level 1 alarm
Module high temperature level 1 alarm
Module low temperature level 1 alarm
Error code
E12
E22
E32
E42
E52
E62
E72
E82
-
E92
E102
E112
E122
Meaning
Module equipment failure level 2 alarm
Module communication abnormal level 2 alarm
Module address abnormal level 2 alarm
Module balance abnormal level 2 alarm
Module overvoltage level 2 alarm
Module undervoltage level 2 alarm
Module charging overcurrent level 2 alarm
Module discharging overcurrent level 2 alarm
-
Single cell overvoltage level 2 alarm
Single cell undervoltage level 2 alarm
Module high temperature level 2 alarm
Module low temperature level 2 alarm

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
3. BMS protection threshold
Power off:
①Long press the switch (about 6S).
②The green light goes out briefly and then flashes to enter the self-test (about 10S). After that, the
battery will be completely power-off.
Running:
①Short press the switch to switch the display page.
②Long press the switch (about 3~6S) to put the battery pack into sleep mode.
Sleep:
①Short press the switch, no change.
②Long press the switch (about 3~6S) to wake up the battery pack.
Remark: ①In the long press state, the user need to release the press after pressing for 3~6S, other-
wise it may fail. ②If the wake-up fails, wait for 10S to wake up again; after under-voltage automat-
ic sleep, only charging wake-up is supported.
(5) USB
This battery pack provides dual USB power outputs(5V/2.1A), which can support power supply for
common low-voltage equipment.
This function can only be used when the battery is running normally, and cannot be used in sleep
mode.
3.1 Temp. control threshold value
Level
Running normal
Alarm
Protection
Alarm
Protection
Alarm
Protection
Item
Normal operation temp. 10<Tpmin<35
-20<Tpmin≤-15
Tpmin≤-20
75≤Tpmax<85
Tpmax>85
60≤Tpmax<65
Tpmax>65
-
≥-13
≥-15
≤65
≤75
≤57
≤60
Code
-
E121
E122
E111
E112
E111
E112
Temp. protection recovery
value(°C); delay (5S)
Tpmin / Tpmax(°C);
delay (3S) Remark
-
Environmental low temp.
threshold value
Radiator high temp.
threshold value
Battery cell high temp.
threshold value
The low temperature
environment is the collection
channel of the radiator and
the battery cell.
1 heat sink temperature
acquisition channel
3 cell temperature acquisition
channels
Remark:
It cannot be charged or discharged when in the Protection process.

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
Remark:
Charge and discharge overcurrent protection: After charging protection, it cannot be charged
but can be discharged; after discharge protection, it cannot be discharged but can be charged.
3.4 Use of Bluetooth
(1) User can download the battery Bluetooth APP by searching for Sunstone Batteriemonitor on
the Google Play, or from the link below(Please open in a browser other than Google Chrome):
https://www.sunstonepower.com/download.html
Install the APP. After the installation is successful, the APP icon will be generated, as shown below:
(2) Turn on the Bluetooth of the mobile phone, and open the APP, and find the corresponding
battery pack according to the battery name in the upper left corner of the battery pack, as shown
below:
3.3 Current threshold value
Item
Undervoltage alarm
Normal
Overvoltage alarm
Item
Normal
Undervoltage protection
(Turn off discharging)
Overvoltage protection
(Turn off charging)
Charge and discharge
overcurrent alarm
Charge and discharge
overcurrent protection
Short circuit protection
Recovery after 5S
Recovery after 5S
Code
E101
E102
-
E91
E92
2.5<Vmin≤2.9
Vmin≤2.5
2.9<V<3.65
3.65≤Vmax<3.75
Vmax≥3.75
≥3.1
≥2.8
-
≤3.4
≤3.45
3.2 Voltage threshold value
Cell voltage range (V);
delay (3S)
Cell voltage recovery value (V);
delay (5S)
Code
-
Charge E71 / Discharge E81
Charge E72 / Discharge E82
E83
<75
75≤Imax≤105
Imax >105
Imax >200
(within 1mS)
-
<70A
Current value (A);
delay (3S)
Current recovery value (A);
delay (5S)

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
(4) After the connection is successful, the user can see the parameter interface of the battery pack,
which mainly consists of the following parameters, as shown below:
(3) Select the battery pack the user need to connect, as shown below:

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
4. Daily use and maintenance of battery pack
4.1 Daily maintenance of battery pack
(1) Check the voltage data on the BMS display and the actual battery voltage value to ensure the
accuracy of the voltage collection of the BMS. If they are inconsistent, proofreading is required. The
error between the collected voltage and the actual battery voltage does not exceed 10mV.
(2) Check the temperature collection data and actual temperature value of the BMS, and the data
error between the collected data and the actual temperature value is not allowed to exceed 3℃, to
ensure that the battery will not be charged or discharged when the temperature is too high or too
low.
(3) Check the BMS current collected data and actual current value, the error is not allowed to exceed
1%, to ensure that the battery will not be charged or discharged by overcurrent.
(4) Check the reliability of the charging equipment to ensure that the charging equipment performs
charging according to the voltage and current regulationsent by the BMS, to ensure that the battery
will not be overcharged.
(5) Check the connection of the battery pack is good, the contact points are in normal contact, and
there is no accumulation of dust, powder, metal chips.
4.2 Caution
(1) Children are not allowed to use the batteries.
(2) It is forbidden to disassemble the battery.

Sunstone Power Industrial GmbH PT. Solid Power Energi Indonesia Sunstone Power Industry Co., Ltd.
Nobelring 13, 60598 Frankfurt (M) Germany
Komplek Duta Indah Iconic, Blok. C No. 2 Jl. 1803A, Tiley Central Plaza. Shenzhen, China
www.sunstonepower.de MH Thamrin KM.2 Kebon Nanas, Tangerang 15143 Indonesia www.sunstonepower.com
info@sunstonepower.de info@solidpower.co.id info@sunstonepower.com
(3) Keep batteries or battery packs away from dangerous items or materials, such as corrosive chemi-
cals, dangerous machinery and equipment, and high-temperature environments.
(4) Unreasonable use of this of products may cause smoke, such as external short circuit, overcharg-
ing, and high ambient temperature. If smoke occurs, please cut off the power in time, use carbon
dioxide or dry powder fire extinguisher for treatment, and bury it with sand or mud. The crowd must
be evacuated in time during the entire process.
(5) Unreasonable use of this series of products may cause the single battery to swell. In severe cases,
it may cause the casing to rupture or crack. In these conditions, the battery should be stopped imme-
diately. Please contact our technical department or after-sales service department for further solution.
(6) It is forbidden to short circuit the positive and negative terminal of the battery directly, and avoid
any metal or other conductive objects contacting the positive and negative terminal of the battery.
This operation may cause personal injury or property damage.
(7) It is forbidden to immerse the battery in water or other conductive liquids. This operation may
cause personal injury or property damage.
(8) It is forbidden to use this product in series or parallel with other types of batteries. It is also forbid-
den to connect the whole system in series or parallel operation with other batteries. These operations
may cause personal injury or property lose. If necessary, please contact the relevant technical depart-
ment to obtain the correct technical support.
(9) It is forbidden to get wet under the environment of more than 95%RH, even immerse in water.
Otherwise, it may cause internal short circuit, loss of function or abnormal chemical reaction, and
cause fire, smoke, explosion and other accidents.
(10) It is forbidden to put the battery system into fire or to be exposed to a high temperature envi-
ronment exceeding the temperature conditions specified in this specification for a long time. These
environments above the safe temperature range will cause a significant decrease in the performance
and life of this product, and even cause serious consequences such as combustion and explosion.
(11) It is forbidden to store and use in an environment with high static electricity or high electromag-
netic radiation. Otherwise, the electronic devices in this product will be damaged, which may cause
potential safety hazards.
(12) Connect the positive and negative terminal of the battery system strictly in accordance with the
instructions, and reverse charging is prohibited.
(13) When the electrolyte leaks, avoid contacting the electrolyte with skin and eyes. In case of con-
tact, wash the area with plenty of water and seek medical assistance. It is forbidden for any person
or animal to swallow any part of the battery system or the substance contained in the battery system.
(14) Protect the battery system as much as possible to avoid mechanical vibration, collision and
pressure shock, otherwise the battery system may short circuit, resulting in high temperature and
fire.